Certificate holders

Subtype

DAIKIN ALTHERMA 3 GEO 6KW

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0337
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 GEO 6KW
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R32
Mass of Refrigerant

1,700 kg

Certification Date
14.06.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 8

Models

EGSAH06D9W _1P
Configure model
Model name
EGSAH06D9W _1P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.35 kW

3.26 kW

El input

0.74 kW

1.33 kW

COP

4.51

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

152 %

Prated

6.00 kW

6.20 kW

SCOP

5.13

4.00

Tbiv

-22 °C

-22 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.57 kW

3.75 kW

COP Tj = -7°C

5.34

3.84

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

2.17 kW

2.28 kW

COP Tj = +2°C

5.18

3.84

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

1.50 kW

1.63 kW

COP Tj = +7°C

5.46

4.60

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.15 kW

1.01 kW

COP Tj = 12°C

4.73

3.99

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2884 kWh

3820 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

6.00 kW

6.20 kW

SCOP

5.06

3.72

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.57 kW

5.46 kW

COP Tj = -7°C

4.84

3.13

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

3.35 kW

3.25 kW

COP Tj = +2°C

5.36

3.81

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

2.05 kW

2.24 kW

COP Tj = +7°C

5.42

4.33

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.05 kW

0.96 kW

COP Tj = 12°C

4.57

3.65

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2447 kWh

3447 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAH06D9W _3P
Configure model
Model name
EGSAH06D9W _3P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.35 kW

3.26 kW

El input

0.74 kW

1.33 kW

COP

4.51

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

6.00 kW

6.20 kW

SCOP

5.06

3.72

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.57 kW

5.46 kW

COP Tj = -7°C

4.84

3.13

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

3.35 kW

3.25 kW

COP Tj = +2°C

5.36

3.81

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

2.05 kW

2.24 kW

COP Tj = +7°C

5.42

4.33

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.05 kW

0.96 kW

COP Tj = 12°C

4.57

3.65

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2447 kWh

3447 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

197 %

152 %

Prated

6.00 kW

6.20 kW

SCOP

5.13

4.00

Tbiv

-22 °C

-22 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.57 kW

3.75 kW

COP Tj = -7°C

5.34

3.84

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

2.17 kW

2.28 kW

COP Tj = +2°C

5.18

3.84

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

1.50 kW

1.63 kW

COP Tj = +7°C

5.46

4.60

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.15 kW

1.01 kW

COP Tj = 12°C

4.73

3.99

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2884 kWh

3820 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAH06UD9W _1P
Configure model
Model name
EGSAH06UD9W _1P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.35 kW

3.26 kW

El input

0.74 kW

1.33 kW

COP

4.51

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

6.00 kW

6.20 kW

SCOP

5.06

3.72

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.57 kW

5.46 kW

COP Tj = -7°C

4.84

3.13

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

3.35 kW

3.25 kW

COP Tj = +2°C

5.36

3.81

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

2.05 kW

2.24 kW

COP Tj = +7°C

5.42

4.33

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.05 kW

0.96 kW

COP Tj = 12°C

4.57

3.65

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2447 kWh

3447 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

197 %

152 %

Prated

6.00 kW

6.20 kW

SCOP

5.13

4.00

Tbiv

-22 °C

-22 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.57 kW

3.75 kW

COP Tj = -7°C

5.34

3.84

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

2.17 kW

2.28 kW

COP Tj = +2°C

5.18

3.84

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

1.50 kW

1.63 kW

COP Tj = +7°C

5.46

4.60

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.15 kW

1.01 kW

COP Tj = 12°C

4.73

3.99

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2884 kWh

3820 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAH06UD9W _3P
Configure model
Model name
EGSAH06UD9W _3P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.35 kW

3.26 kW

El input

0.74 kW

1.33 kW

COP

4.51

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

6.00 kW

6.20 kW

SCOP

5.06

3.72

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.57 kW

5.46 kW

COP Tj = -7°C

4.84

3.13

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

3.35 kW

3.25 kW

COP Tj = +2°C

5.36

3.81

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

2.05 kW

2.24 kW

COP Tj = +7°C

5.42

4.33

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.05 kW

0.96 kW

COP Tj = 12°C

4.57

3.65

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2447 kWh

3447 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

197 %

152 %

Prated

6.00 kW

6.20 kW

SCOP

5.13

4.00

Tbiv

-22 °C

-22 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.57 kW

3.75 kW

COP Tj = -7°C

5.34

3.84

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

2.17 kW

2.28 kW

COP Tj = +2°C

5.18

3.84

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

1.50 kW

1.63 kW

COP Tj = +7°C

5.46

4.60

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.15 kW

1.01 kW

COP Tj = 12°C

4.73

3.99

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2884 kWh

3820 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAX06D9W(G) _1P
Configure model
Model name
EGSAX06D9W(G) _1P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.35 kW

3.26 kW

El input

0.74 kW

1.33 kW

COP

4.51

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

143 %

Prated

6.00 kW

6.20 kW

SCOP

5.18

3.77

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.57 kW

5.46 kW

COP Tj = -7°C

4.84

3.13

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

3.35 kW

3.25 kW

COP Tj = +2°C

5.36

3.81

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

2.05 kW

2.24 kW

COP Tj = +7°C

5.42

4.33

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.05 kW

0.96 kW

COP Tj = 12°C

4.57

3.65

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2393 kWh

3393 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

6.00 kW

6.20 kW

SCOP

5.19

4.03

Tbiv

-22 °C

-22 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.57 kW

3.75 kW

COP Tj = -7°C

5.34

3.84

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

2.17 kW

2.28 kW

COP Tj = +2°C

5.18

3.84

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

1.50 kW

1.63 kW

COP Tj = +7°C

5.46

4.60

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.15 kW

1.01 kW

COP Tj = 12°C

4.73

3.99

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2851 kWh

3787 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAX06D9W(G) _3P
Configure model
Model name
EGSAX06D9W(G) _3P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.35 kW

3.26 kW

El input

0.74 kW

1.33 kW

COP

4.51

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

143 %

Prated

6.00 kW

6.20 kW

SCOP

5.18

3.77

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.57 kW

5.46 kW

COP Tj = -7°C

4.84

3.13

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

3.35 kW

3.25 kW

COP Tj = +2°C

5.36

3.81

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

2.05 kW

2.24 kW

COP Tj = +7°C

5.42

4.33

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.05 kW

0.96 kW

COP Tj = 12°C

4.57

3.65

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2393 kWh

3393 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

199 %

152 %

Prated

6.00 kW

6.20 kW

SCOP

5.19

4.03

Tbiv

-22 °C

-22 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.57 kW

3.75 kW

COP Tj = -7°C

5.34

3.84

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

2.17 kW

2.28 kW

COP Tj = +2°C

5.18

3.84

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

1.50 kW

1.63 kW

COP Tj = +7°C

5.46

4.60

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.15 kW

1.01 kW

COP Tj = 12°C

4.73

3.99

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2851 kWh

3787 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAX06UD9W _1P
Configure model
Model name
EGSAX06UD9W _1P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.35 kW

3.26 kW

El input

0.74 kW

1.33 kW

COP

4.51

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

153 %

Prated

6.00 kW

6.20 kW

SCOP

5.19

4.03

Tbiv

-22 °C

-22 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.57 kW

3.75 kW

COP Tj = -7°C

5.34

3.84

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

2.17 kW

2.28 kW

COP Tj = +2°C

5.18

3.84

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

1.50 kW

1.63 kW

COP Tj = +7°C

5.46

4.60

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.15 kW

1.01 kW

COP Tj = 12°C

4.73

3.99

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2851 kWh

3787 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

143 %

Prated

6.00 kW

6.20 kW

SCOP

5.18

3.77

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.57 kW

5.46 kW

COP Tj = -7°C

4.84

3.13

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

3.35 kW

3.25 kW

COP Tj = +2°C

5.36

3.81

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

2.05 kW

2.24 kW

COP Tj = +7°C

5.42

4.33

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.05 kW

0.96 kW

COP Tj = 12°C

4.57

3.65

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2393 kWh

3393 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAX06UD9W _3P
Configure model
Model name
EGSAX06UD9W _3P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.35 kW

3.26 kW

El input

0.74 kW

1.33 kW

COP

4.51

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

143 %

Prated

6.00 kW

6.20 kW

SCOP

5.18

3.77

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.57 kW

5.46 kW

COP Tj = -7°C

4.84

3.13

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

3.35 kW

3.25 kW

COP Tj = +2°C

5.36

3.81

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

2.05 kW

2.24 kW

COP Tj = +7°C

5.42

4.33

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.05 kW

0.96 kW

COP Tj = 12°C

4.57

3.65

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2393 kWh

3393 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

199 %

152 %

Prated

6.00 kW

6.20 kW

SCOP

5.19

4.03

Tbiv

-22 °C

-22 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.57 kW

3.75 kW

COP Tj = -7°C

5.34

3.84

Cdh Tj = -7 °C

0.980

1.000

Pdh Tj = +2°C

2.17 kW

2.28 kW

COP Tj = +2°C

5.18

3.84

Cdh Tj = +2 °C

0.960

1.000

Pdh Tj = +7°C

1.50 kW

1.63 kW

COP Tj = +7°C

5.46

4.60

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.15 kW

1.01 kW

COP Tj = 12°C

4.73

3.99

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

5.95 kW

6.44 kW

COP Tj = Tbiv

4.67

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.95 kW

6.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.67

2.90

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.00 kW

Annual energy consumption Qhe

2851 kWh

3787 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l