1,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
7.62 kW
El input
1.96 kW
3.46 kW
COP
1.77
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
121 %
Prated
6.80 kW
5.31 kW
SCOP
4.24
3.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
4.78 kW
COP Tj = -7°C
2.64
1.90
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.58 kW
2.80 kW
COP Tj = +2°C
4.22
3.11
Cdh Tj = +2 °C
0.980
0.981
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.51
3.96
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
3.91 kW
3.81 kW
COP Tj = 12°C
6.40
5.22
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.80 kW
5.31 kW
COP Tj = Tbiv
2.54
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
5.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3311 kWh
3535 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
7.62 kW
El input
1.96 kW
3.46 kW
COP
1.77
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
121 %
Prated
6.80 kW
5.31 kW
SCOP
4.24
3.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
4.78 kW
COP Tj = -7°C
2.64
1.90
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.58 kW
2.80 kW
COP Tj = +2°C
4.22
3.11
Cdh Tj = +2 °C
0.980
0.981
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.51
3.96
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
3.91 kW
3.81 kW
COP Tj = 12°C
6.40
5.22
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.80 kW
5.31 kW
COP Tj = Tbiv
2.54
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
5.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3311 kWh
3535 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
7.62 kW
El input
1.96 kW
3.46 kW
COP
1.77
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
121 %
Prated
6.80 kW
5.31 kW
SCOP
4.24
3.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
4.78 kW
COP Tj = -7°C
2.64
1.90
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.58 kW
2.80 kW
COP Tj = +2°C
4.22
3.11
Cdh Tj = +2 °C
0.980
0.981
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.51
3.96
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
3.91 kW
3.81 kW
COP Tj = 12°C
6.40
5.22
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.80 kW
5.31 kW
COP Tj = Tbiv
2.54
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
5.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3311 kWh
3535 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
94 %
COP
2.22
Heating up time
02:11 h:min
Standby power input
58.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
254 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
7.62 kW
El input
1.96 kW
3.46 kW
COP
1.77
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
121 %
Prated
6.80 kW
5.31 kW
SCOP
4.24
3.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
4.78 kW
COP Tj = -7°C
2.64
1.90
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.58 kW
2.80 kW
COP Tj = +2°C
4.22
3.11
Cdh Tj = +2 °C
0.980
0.981
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.51
3.96
Cdh Tj = +7 °C
0.973
0.979
Pdh Tj = 12°C
3.91 kW
3.81 kW
COP Tj = 12°C
6.40
5.22
Cdh Tj = +12 °C
0.972
0.977
Pdh Tj = Tbiv
6.80 kW
5.31 kW
COP Tj = Tbiv
2.54
1.54
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.80 kW
5.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3311 kWh
3535 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
87 %
COP
2.04
Heating up time
02:08 h:min
Standby power input
62.2 W
Reference hot water temperature
51.1 °C
Mixed water at 40°C
238 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
6.80 kW
El input
1.96 kW
2.99 kW
COP
1.77
2.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
122 %
Prated
5.84 kW
4.78 kW
SCOP
4.46
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.20 kW
COP Tj = -7°C
3.04
1.91
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
3.01 kW
2.52 kW
COP Tj = +2°C
4.53
3.09
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.57
4.08
Cdh Tj = +7 °C
0.973
0.978
Pdh Tj = 12°C
3.49 kW
3.81 kW
COP Tj = 12°C
5.57
5.35
Cdh Tj = +12 °C
0.973
0.976
Pdh Tj = Tbiv
5.84 kW
4.77 kW
COP Tj = Tbiv
2.68
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
4.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2708 kWh
3163 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
6.80 kW
El input
1.96 kW
2.99 kW
COP
1.77
2.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
122 %
Prated
5.84 kW
4.78 kW
SCOP
4.46
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.20 kW
COP Tj = -7°C
3.04
1.91
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
3.01 kW
2.52 kW
COP Tj = +2°C
4.53
3.09
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.57
4.08
Cdh Tj = +7 °C
0.973
0.978
Pdh Tj = 12°C
3.49 kW
3.81 kW
COP Tj = 12°C
5.57
5.35
Cdh Tj = +12 °C
0.973
0.976
Pdh Tj = Tbiv
5.84 kW
4.77 kW
COP Tj = Tbiv
2.68
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
4.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2708 kWh
3163 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
6.80 kW
El input
1.96 kW
2.99 kW
COP
1.77
2.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
122 %
Prated
5.84 kW
4.78 kW
SCOP
4.46
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.20 kW
COP Tj = -7°C
3.04
1.91
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
3.01 kW
2.52 kW
COP Tj = +2°C
4.53
3.09
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.57
4.08
Cdh Tj = +7 °C
0.973
0.978
Pdh Tj = 12°C
3.49 kW
3.81 kW
COP Tj = 12°C
5.57
5.35
Cdh Tj = +12 °C
0.973
0.976
Pdh Tj = Tbiv
5.84 kW
4.77 kW
COP Tj = Tbiv
2.68
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
4.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2708 kWh
3163 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
94 %
COP
2.22
Heating up time
02:11 h:min
Standby power input
58.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
254 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.47 kW
6.80 kW
El input
1.96 kW
2.99 kW
COP
1.77
2.27
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
122 %
Prated
5.84 kW
4.78 kW
SCOP
4.46
3.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
4.20 kW
COP Tj = -7°C
3.04
1.91
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
3.01 kW
2.52 kW
COP Tj = +2°C
4.53
3.09
Cdh Tj = +2 °C
0.974
0.979
Pdh Tj = +7°C
3.49 kW
3.16 kW
COP Tj = +7°C
5.57
4.08
Cdh Tj = +7 °C
0.973
0.978
Pdh Tj = 12°C
3.49 kW
3.81 kW
COP Tj = 12°C
5.57
5.35
Cdh Tj = +12 °C
0.973
0.976
Pdh Tj = Tbiv
5.84 kW
4.77 kW
COP Tj = Tbiv
2.68
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
4.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
57 °C
57 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
16 W
16 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2708 kWh
3163 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
87 %
COP
2.04
Heating up time
02:08 h:min
Standby power input
62.2 W
Reference hot water temperature
51.1 °C
Mixed water at 40°C
238 l