Certificate holders

Subtype

Bosch Compress 3000 AWS-8

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
011-1W0135
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Bosch Compress 3000 AWS-8
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,600 kg

Certification Date
18.07.2017
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 4

Models

Bosch Compress 3000 AWS-8 E
Configure model
Model name
Bosch Compress 3000 AWS-8 E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.23 kW

7.96 kW

El input

0.72 kW

3.60 kW

COP

4.50

2.21

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

7.43 kW

5.20 kW

SCOP

4.74

3.35

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-9 °C

Pdh Tj = -7°C

6.63 kW

4.55 kW

COP Tj = -7°C

3.08

2.00

Cdh Tj = -7 °C

0.994

0.994

Pdh Tj = +2°C

4.00 kW

3.94 kW

COP Tj = +2°C

4.75

3.41

Cdh Tj = +2 °C

0.985

0.989

Pdh Tj = +7°C

3.66 kW

3.46 kW

COP Tj = +7°C

5.96

4.41

Cdh Tj = +7 °C

0.979

0.984

Pdh Tj = 12°C

3.99 kW

4.14 kW

COP Tj = 12°C

6.82

5.84

Cdh Tj = +12 °C

0.978

0.982

Pdh Tj = Tbiv

7.44 kW

5.02 kW

COP Tj = Tbiv

2.51

1.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.44 kW

5.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

57 °C

57 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

17 W

17 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

5.20 kW

Annual energy consumption Qhe

3236 kWh

3206 kWh

Bosch Compress 3000 AWS-8 B
Configure model
Model name
Bosch Compress 3000 AWS-8 B
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.23 kW

7.96 kW

El input

0.72 kW

3.60 kW

COP

4.50

2.21

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

7.43 kW

5.20 kW

SCOP

4.74

3.35

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-9 °C

Pdh Tj = -7°C

6.63 kW

4.55 kW

COP Tj = -7°C

3.08

2.00

Cdh Tj = -7 °C

0.994

0.994

Pdh Tj = +2°C

4.00 kW

3.94 kW

COP Tj = +2°C

4.75

3.41

Cdh Tj = +2 °C

0.985

0.989

Pdh Tj = +7°C

3.66 kW

3.46 kW

COP Tj = +7°C

5.96

4.41

Cdh Tj = +7 °C

0.979

0.984

Pdh Tj = 12°C

3.99 kW

4.14 kW

COP Tj = 12°C

6.82

5.84

Cdh Tj = +12 °C

0.978

0.982

Pdh Tj = Tbiv

7.44 kW

5.02 kW

COP Tj = Tbiv

2.51

1.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.44 kW

5.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

57 °C

57 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

17 W

17 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3236 kWh

3206 kWh

Bosch Compress 3000 AWS-8 M
Configure model
Model name
Bosch Compress 3000 AWS-8 M
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.23 kW

7.96 kW

El input

0.72 kW

3.60 kW

COP

4.50

2.21

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

7.43 kW

5.20 kW

SCOP

4.74

3.35

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-9 °C

Pdh Tj = -7°C

6.63 kW

4.55 kW

COP Tj = -7°C

3.08

2.00

Cdh Tj = -7 °C

0.994

0.994

Pdh Tj = +2°C

4.00 kW

3.94 kW

COP Tj = +2°C

4.75

3.41

Cdh Tj = +2 °C

0.985

0.989

Pdh Tj = +7°C

3.66 kW

3.46 kW

COP Tj = +7°C

5.96

4.41

Cdh Tj = +7 °C

0.979

0.984

Pdh Tj = 12°C

3.99 kW

4.14 kW

COP Tj = 12°C

6.82

5.84

Cdh Tj = +12 °C

0.978

0.982

Pdh Tj = Tbiv

7.44 kW

5.02 kW

COP Tj = Tbiv

2.51

1.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.44 kW

5.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

57 °C

57 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

17 W

17 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

5.20 kW

Annual energy consumption Qhe

3236 kWh

3206 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.30

Heating up time

02:07 h:min

Standby power input

65.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

257 l

Bosch Compress 3000 AWS-8 MS
Configure model
Model name
Bosch Compress 3000 AWS-8 MS
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.23 kW

7.96 kW

El input

0.72 kW

3.60 kW

COP

4.50

2.21

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

131 %

Prated

7.43 kW

5.20 kW

SCOP

4.74

3.35

Tbiv

-10 °C

-9 °C

TOL

-10 °C

-9 °C

Pdh Tj = -7°C

6.63 kW

4.55 kW

COP Tj = -7°C

3.08

2.00

Cdh Tj = -7 °C

0.994

0.994

Pdh Tj = +2°C

4.00 kW

3.94 kW

COP Tj = +2°C

4.75

3.41

Cdh Tj = +2 °C

0.985

0.989

Pdh Tj = +7°C

3.66 kW

3.46 kW

COP Tj = +7°C

5.96

4.41

Cdh Tj = +7 °C

0.979

0.984

Pdh Tj = 12°C

3.99 kW

4.14 kW

COP Tj = 12°C

6.82

5.84

Cdh Tj = +12 °C

0.978

0.982

Pdh Tj = Tbiv

7.44 kW

5.02 kW

COP Tj = Tbiv

2.51

1.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.44 kW

5.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

57 °C

57 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

17 W

17 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

5.20 kW

Annual energy consumption Qhe

3236 kWh

3206 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.11

Heating up time

02:04 h:min

Standby power input

69.7 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

236 l