Certificate holders

Subtype

i-HPV5H 0140

Certificate Holder
Advantix S.p.A.
Via San Giuseppe Lavoratore, 24
37040 Arcole Verona
Italy
Registration number
ICIM-PDC-000133
Certification Body
ICIM S.p.A.
Subtype title
i-HPV5H 0140
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

6,500 kg

Certification Date
25.02.2022
Testing basis
Heat Pump KEYMARK V9
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

i-HPV5H 0140
Configure model
Model name
i-HPV5H 0140
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

40.00 kW

38.40 kW

El input

9.84 kW

14.20 kW

COP

4.07

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

9.54 kW

Cooling capacity

29.60

EER

3.10

EN 14825

+7°C/+12°C

Pdesignc

29.60 kW

SEER

4.80

Pdc Tj = 35°C

29.60 kW

EER Tj = 35°C

3.10

Pdc Tj = 30°C

21.70 kW

EER Tj = 30°C

4.14

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

15.00 kW

EER Tj = 25°C

5.00

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

16.19 kW

EER Tj = 20°C

6.57

Cdc Tj = 20 °C

1.000

Poff

22 W

PTO

0 W

PSB

28 W

PCK

0 W

Annual energy consumption Qce

3700 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

74 dB(A)

74 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

126 %

Prated

31.00 kW

29.00 kW

SCOP

4.25

3.23

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-9 °C

Pdh Tj = -7°C

27.10 kW

25.80 kW

COP Tj = -7°C

2.49

1.72

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

17.60 kW

17.10 kW

COP Tj = +2°C

4.23

3.10

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

18.00 kW

20.20 kW

COP Tj = +7°C

5.54

4.59

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

20.20 kW

22.90 kW

COP Tj = 12°C

7.11

7.25

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

27.10 kW

25.80 kW

COP Tj = Tbiv

2.49

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

26.90 kW

25.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

58 °C

58 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

38 W

38 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

4.10 kW

29.00 kW

Annual energy consumption Qhe

14894 kWh

18669 kWh