Certificate holders

Subtype

Riello NXHM 18 22 26 30 kW

Certificate Holder
Riello S.p.A.
Via Ing. Pilade Riello 7
37045 Legnago (VR)
Italy
Registration number
041-K019-04
Certification Body
BRE Global Limited
Subtype title
Riello NXHM 18 22 26 30 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

5,000 kg

Certification Date
18.11.2021
Testing basis
Heat Pump Keymark Scheme Rules Rev 08
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

NXHM 018T
Configure model
Model name
NXHM 018T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.32 kW

18.10 kW

El input

3.96 kW

6.63 kW

COP

4.63

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

157 %

Prated

17.67 kW

18.07 kW

SCOP

5.74

4.00

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

17.67 kW

18.07 kW

COP Tj = +2°C

3.53

2.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

11.36 kW

11.62 kW

COP Tj = +7°C

5.16

3.49

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.45 kW

5.35 kW

COP Tj = 12°C

7.01

5.09

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.36 kW

11.62 kW

COP Tj = Tbiv

5.16

3.49

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.67 kW

18.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4116 kWh

6041 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

97 %

Prated

17.76 kW

18.38 kW

SCOP

3.73

2.50

Tbiv

-15 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

11.21 kW

11.13 kW

COP Tj = -7°C

3.09

1.98

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

6.64 kW

6.65 kW

COP Tj = +2°C

4.50

3.44

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.77 kW

4.66 kW

COP Tj = +7°C

5.85

4.35

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.95 kW

3.74 kW

COP Tj = 12°C

7.18

5.68

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

14.49 kW

11.13 kW

COP Tj = Tbiv

2.42

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.14 kW

13.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.67

1.21

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.62 kW

18.38 kW

Annual energy consumption Qhe

11740 kWh

18156 kWh

Pdh Tj = -15°C (if TOL<-20°C)

14.49

13.56

COP Tj = -15°C (if TOL<-20°C)

2.42

1.21

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

125 %

Prated

17.99 kW

17.67 kW

SCOP

4.60

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

15.90 kW

15.61 kW

COP Tj = -7°C

2.85

1.72

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.66 kW

9.59 kW

COP Tj = +2°C

4.59

3.32

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.56 kW

6.37 kW

COP Tj = +7°C

5.99

4.48

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.76 kW

3.57 kW

COP Tj = 12°C

7.08

5.27

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

15.90 kW

15.61 kW

COP Tj = Tbiv

2.85

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.99 kW

15.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.49

1.17

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

2.64 kW

Annual energy consumption Qhe

8086 kWh

11375 kWh

NXHM 022T
Configure model
Model name
NXHM 022T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

22.30 kW

22.10 kW

El input

5.13 kW

8.33 kW

COP

4.35

2.65

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

161 %

Prated

21.90 kW

22.01 kW

SCOP

5.85

4.09

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

21.81 kW

22.01 kW

COP Tj = +2°C

3.31

2.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

14.08 kW

14.15 kW

COP Tj = +7°C

5.20

3.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.44 kW

6.38 kW

COP Tj = 12°C

7.50

5.34

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.08 kW

14.15 kW

COP Tj = Tbiv

5.20

3.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

21.81 kW

22.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.31

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.00 kW

Annual energy consumption Qhe

4945 kWh

7180 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

102 %

Prated

21.40 kW

22.36 kW

SCOP

3.72

2.62

Tbiv

-15 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

13.30 kW

13.53 kW

COP Tj = -7°C

3.12

2.07

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.25 kW

8.61 kW

COP Tj = +2°C

4.42

3.70

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.45 kW

5.21 kW

COP Tj = +7°C

5.87

4.49

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.98 kW

3.74 kW

COP Tj = 12°C

7.19

5.76

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

17.46 kW

13.53 kW

COP Tj = Tbiv

2.36

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.27 kW

13.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.69

1.24

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.13 kW

22.36 kW

Annual energy consumption Qhe

14179 kWh

21067 kWh

Pdh Tj = -15°C (if TOL<-20°C)

17.46

13.78

COP Tj = -15°C (if TOL<-20°C)

2.36

1.24

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

126 %

Prated

22.31 kW

22.43 kW

SCOP

4.53

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

19.72 kW

19.82 kW

COP Tj = -7°C

2.74

1.74

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

12.03 kW

11.89 kW

COP Tj = +2°C

4.41

3.32

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

8.00 kW

7.97 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.79 kW

3.60 kW

COP Tj = 12°C

7.14

5.32

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.72 kW

19.82 kW

COP Tj = Tbiv

2.74

1.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.33 kW

13.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.08

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

8.60 kW

Annual energy consumption Qhe

10180 kWh

14390 kWh

NXHM 026T
Configure model
Model name
NXHM 026T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

26.30 kW

26.06 kW

El input

6.50 kW

10.72 kW

COP

4.05

2.43

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

168 %

Prated

26.08 kW

26.22 kW

SCOP

5.85

4.26

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

25.50 kW

26.22 kW

COP Tj = +2°C

3.00

1.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

16.77 kW

16.86 kW

COP Tj = +7°C

5.02

3.47

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.65 kW

7.58 kW

COP Tj = 12°C

7.78

5.94

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.77 kW

16.86 kW

COP Tj = Tbiv

5.02

3.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.50 kW

26.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

1.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.58 kW

0.00 kW

Annual energy consumption Qhe

5959 kWh

8218 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

101 %

Prated

25.75 kW

26.27 kW

SCOP

3.64

2.59

Tbiv

-12 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

15.91 kW

15.90 kW

COP Tj = -7°C

3.10

2.10

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

10.10 kW

10.17 kW

COP Tj = +2°C

4.45

3.58

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

6.30 kW

6.52 kW

COP Tj = +7°C

6.06

4.99

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.03 kW

3.63 kW

COP Tj = 12°C

7.13

5.68

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

18.97 kW

15.90 kW

COP Tj = Tbiv

2.36

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.07 kW

13.37 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.67

1.20

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

12.68 kW

26.27 kW

Annual energy consumption Qhe

17421 kWh

24967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

18.95

13.37

COP Tj = -15°C (if TOL<-20°C)

2.27

1.20

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

123 %

Prated

25.04 kW

26.15 kW

SCOP

4.50

3.14

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.12 kW

20.64 kW

COP Tj = -7°C

2.57

1.69

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

13.76 kW

14.26 kW

COP Tj = +2°C

4.44

3.12

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

9.36 kW

9.29 kW

COP Tj = +7°C

6.52

4.74

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.09 kW

3.89 kW

COP Tj = 12°C

7.35

5.48

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

22.12 kW

22.11 kW

COP Tj = Tbiv

2.57

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.33 kW

13.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.08

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.68 kW

12.28 kW

Annual energy consumption Qhe

11489 kWh

17204 kWh

NXHM 030T
Configure model
Model name
NXHM 030T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

29.93 kW

29.68 kW

El input

8.02 kW

12.97 kW

COP

3.73

2.29

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

77 dB(A)

77 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

213 %

163 %

Prated

30.44 kW

29.73 kW

SCOP

5.39

4.15

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

26.29 kW

26.41 kW

COP Tj = +2°C

2.94

1.99

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

19.57 kW

19.11 kW

COP Tj = +7°C

4.75

3.37

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

8.90 kW

8.92 kW

COP Tj = 12°C

7.53

6.09

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.57 kW

19.11 kW

COP Tj = Tbiv

4.75

3.37

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

26.29 kW

26.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.94

1.99

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.15 kW

3.32 kW

Annual energy consumption Qhe

7540 kWh

9580 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

77 dB(A)

77 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

138 %

100 %

Prated

29.13 kW

30.41 kW

SCOP

3.52

2.56

Tbiv

-10 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

18.49 kW

18.40 kW

COP Tj = -7°C

3.07

2.10

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

11.88 kW

11.22 kW

COP Tj = +2°C

4.42

3.51

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

7.53 kW

7.42 kW

COP Tj = +7°C

6.15

5.18

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.11 kW

3.64 kW

COP Tj = 12°C

6.87

5.73

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.93 kW

18.40 kW

COP Tj = Tbiv

2.44

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.17 kW

13.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.67

1.18

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

15.96 kW

30.41 kW

Annual energy consumption Qhe

20390 kWh

29238 kWh

Pdh Tj = -15°C (if TOL<-20°C)

18.61

13.06

COP Tj = -15°C (if TOL<-20°C)

2.24

1.18

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

77 dB(A)

77 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

123 %

Prated

29.18 kW

29.69 kW

SCOP

4.19

3.14

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

21.90 kW

20.11 kW

COP Tj = -7°C

2.54

1.63

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

16.16 kW

16.49 kW

COP Tj = +2°C

4.16

3.09

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

10.64 kW

10.50 kW

COP Tj = +7°C

6.38

4.75

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.54 kW

4.64 kW

COP Tj = 12°C

7.72

5.91

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

23.51 kW

23.97 kW

COP Tj = Tbiv

2.71

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.37 kW

13.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.07

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.75 kW

15.86 kW

Annual energy consumption Qhe

14165 kWh

19316.17 kWh