3,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.12 kW
9.15 kW
El input
2.98 kW
3.62 kW
COP
4.07
2.53
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
223 %
149 %
Prated
11 kW
11 kW
SCOP
5.65
3.81
Tbiv
2 °C
3 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.8 kW
9.82 kW
COP Tj = +2°C
2.87
2.07
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
7.48 kW
7.12 kW
COP Tj = +7°C
5.09
3.26
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
6.12 kW
5.73 kW
COP Tj = 12°C
7.02
4.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
10.8 kW
10.45 kW
COP Tj = Tbiv
2.87
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.8 kW
9.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0 kW
1.18 kW
Annual energy consumption Qhe
2599 kWh
3857 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
132 %
102 %
Prated
10 kW
10 kW
SCOP
3.37
2.64
Tbiv
-15 °C
-13 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
6.34 kW
6.3 kW
COP Tj = -7°C
3.25
2.28
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.45 kW
4.17 kW
COP Tj = +2°C
4.21
3.36
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
5.22 kW
4.98 kW
COP Tj = +7°C
5.15
4.14
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.12 kW
5.95 kW
COP Tj = 12°C
7.02
5.52
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
8.04 kW
7.21 kW
COP Tj = Tbiv
2.06
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.04 kW
6.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.06
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
10 kW
10 kW
Annual energy consumption Qhe
7311 kWh
9349 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.04
6.63
COP Tj = -15°C (if TOL<-20°C)
2.06
1.52
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
119 %
Prated
11 kW
10.3 kW
SCOP
4.23
3.06
Tbiv
-8 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.10 kW
8.29 kW
COP Tj = -7°C
2.48
1.73
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.07 kW
6.10 kW
COP Tj = +2°C
4.36
3.15
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.25 kW
4.84 kW
COP Tj = +7°C
5.22
3.90
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.15 kW
5.89 kW
COP Tj = 12°C
6.59
5.22
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
9.85 kW
8.29 kW
COP Tj = Tbiv
2.42
1.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.32 kW
6.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.68 kW
4.05 kW
Annual energy consumption Qhe
5371 kWh
6961 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.12 kW
9.15 kW
El input
2.98 kW
3.62 kW
COP
4.07
2.53
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
223 %
149 %
Prated
11 kW
11 kW
SCOP
5.65
3.81
Tbiv
2 °C
3 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.8 kW
9.82 kW
COP Tj = +2°C
2.87
2.07
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
7.48 kW
7.12 kW
COP Tj = +7°C
5.09
3.26
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
6.12 kW
5.73 kW
COP Tj = 12°C
7.02
4.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
10.8 kW
10.45 kW
COP Tj = Tbiv
2.87
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.8 kW
9.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
1.18 kW
Annual energy consumption Qhe
2599 kWh
3857 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
132 %
102 %
Prated
10 kW
10 kW
SCOP
3.37
2.64
Tbiv
-15 °C
-13 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
6.34 kW
6.3 kW
COP Tj = -7°C
3.25
2.28
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.45 kW
4.17 kW
COP Tj = +2°C
4.21
3.36
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
5.22 kW
4.98 kW
COP Tj = +7°C
5.15
4.14
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.12 kW
5.95 kW
COP Tj = 12°C
7.02
5.52
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
8.04 kW
7.21 kW
COP Tj = Tbiv
2.06
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.04 kW
6.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.06
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
10 kW
10 kW
Annual energy consumption Qhe
7311 kWh
9349 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.04
6.63
COP Tj = -15°C (if TOL<-20°C)
2.06
1.52
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
119 %
Prated
11 kW
10.3 kW
SCOP
4.23
3.06
Tbiv
-8 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.10 kW
8.29 kW
COP Tj = -7°C
2.48
1.73
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.07 kW
6.10 kW
COP Tj = +2°C
4.36
3.15
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.25 kW
4.84 kW
COP Tj = +7°C
5.22
3.90
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.15 kW
5.89 kW
COP Tj = 12°C
6.59
5.22
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
9.85 kW
8.29 kW
COP Tj = Tbiv
2.42
1.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.32 kW
6.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.68 kW
4.05 kW
Annual energy consumption Qhe
5371 kWh
6961 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.12 kW
9.15 kW
El input
2.98 kW
3.62 kW
COP
4.07
2.53
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
223 %
149 %
Prated
11 kW
11 kW
SCOP
5.65
3.81
Tbiv
2 °C
3 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.8 kW
9.82 kW
COP Tj = +2°C
2.87
2.07
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
7.48 kW
7.12 kW
COP Tj = +7°C
5.09
3.26
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
6.12 kW
5.73 kW
COP Tj = 12°C
7.02
4.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
10.8 kW
10.45 kW
COP Tj = Tbiv
2.87
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.8 kW
9.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
1.18 kW
Annual energy consumption Qhe
2599 kWh
3857 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
132 %
102 %
Prated
10 kW
10 kW
SCOP
3.37
2.64
Tbiv
-15 °C
-13 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
6.34 kW
6.3 kW
COP Tj = -7°C
3.25
2.28
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.45 kW
4.17 kW
COP Tj = +2°C
4.21
3.36
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
5.22 kW
4.98 kW
COP Tj = +7°C
5.15
4.14
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.12 kW
5.95 kW
COP Tj = 12°C
7.02
5.52
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
8.04 kW
7.21 kW
COP Tj = Tbiv
2.06
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.04 kW
6.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.06
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
10 kW
10 kW
Annual energy consumption Qhe
7311 kWh
9349 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.04
6.63
COP Tj = -15°C (if TOL<-20°C)
2.06
1.52
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
119 %
Prated
11 kW
10.3 kW
SCOP
4.23
3.06
Tbiv
-8 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.10 kW
8.29 kW
COP Tj = -7°C
2.48
1.73
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.07 kW
6.10 kW
COP Tj = +2°C
4.36
3.15
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.25 kW
4.84 kW
COP Tj = +7°C
5.22
3.90
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.15 kW
5.89 kW
COP Tj = 12°C
6.59
5.22
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
9.85 kW
8.29 kW
COP Tj = Tbiv
2.42
1.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.32 kW
6.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.68 kW
4.05 kW
Annual energy consumption Qhe
5371 kWh
6961 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.09
Heating up time
01:33 h:min
Standby power input
41.7 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
264 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
79 %
COP
1.93
Heating up time
02:03 h:min
Standby power input
51.2 W
Reference hot water temperature
52.3 °C
Mixed water at 40°C
266 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
104 %
COP
2.52
Heating up time
01:46 h:min
Standby power input
48.3 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
265 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.81 kW
9.15 kW
El input
3.68 kW
3.62 kW
COP
3.75
2.53
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
217 %
147 %
Prated
13 kW
13 kW
SCOP
5.5
3.75
Tbiv
3 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.38 kW
9.82 kW
COP Tj = +2°C
2.77
2.07
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
8.1 kW
8.48 kW
COP Tj = +7°C
4.9
3.2
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
6.12 kW
5.73 kW
COP Tj = 12°C
7.02
4.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
11.74 kW
10.99 kW
COP Tj = Tbiv
2.93
2.41
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.38 kW
9.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.62 kW
3.18 kW
Annual energy consumption Qhe
3158 kWh
4627 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
131 %
103 %
Prated
11 kW
11 kW
SCOP
3.36
2.64
Tbiv
-15 °C
-12 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
6.25 kW
6.75 kW
COP Tj = -7°C
3.21
2.24
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.45 kW
4.22 kW
COP Tj = +2°C
4.26
3.43
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
5.19 kW
4.99 kW
COP Tj = +7°C
4.88
4.17
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.12 kW
5.96 kW
COP Tj = 12°C
7.02
5.55
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
9.35 kW
7.76 kW
COP Tj = Tbiv
2.02
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.35 kW
6.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.02
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
11 kW
11 kW
Annual energy consumption Qhe
8067 kWh
10280 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.35
6.92
COP Tj = -15°C (if TOL<-20°C)
2.02
1.53
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
117 %
Prated
11.6 kW
12 kW
SCOP
4.23
3
Tbiv
-9 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.10 kW
8.29 kW
COP Tj = -7°C
2.48
1.73
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.07 kW
6.40 kW
COP Tj = +2°C
4.36
3.08
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.25 kW
4.93 kW
COP Tj = +7°C
5.22
4.03
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.15 kW
5.91 kW
COP Tj = 12°C
6.59
5.40
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
10.51 kW
8.80 kW
COP Tj = Tbiv
2.25
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.24 kW
6.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.18
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.36 kW
5.75 kW
Annual energy consumption Qhe
5667 kWh
8259 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.81 kW
9.15 kW
El input
3.68 kW
3.62 kW
COP
3.75
2.53
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
217 %
147 %
Prated
13 kW
13 kW
SCOP
5.5
3.75
Tbiv
3 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.38 kW
9.82 kW
COP Tj = +2°C
2.77
2.07
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
8.1 kW
8.48 kW
COP Tj = +7°C
4.9
3.2
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
6.12 kW
5.73 kW
COP Tj = 12°C
7.02
4.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
11.74 kW
10.99 kW
COP Tj = Tbiv
2.93
2.41
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.38 kW
9.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.62 kW
3.18 kW
Annual energy consumption Qhe
3158 kWh
4627 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
131 %
103 %
Prated
11 kW
11 kW
SCOP
3.36
2.64
Tbiv
-15 °C
-12 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
6.25 kW
6.75 kW
COP Tj = -7°C
3.21
2.24
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.45 kW
4.22 kW
COP Tj = +2°C
4.26
3.43
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
5.19 kW
4.99 kW
COP Tj = +7°C
4.88
4.17
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.12 kW
5.96 kW
COP Tj = 12°C
7.02
5.55
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
9.35 kW
7.76 kW
COP Tj = Tbiv
2.02
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.35 kW
6.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.02
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11 kW
11 kW
Annual energy consumption Qhe
8067 kWh
10280 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.35
6.92
COP Tj = -15°C (if TOL<-20°C)
2.02
1.53
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
117 %
Prated
11.6 kW
12 kW
SCOP
4.23
3
Tbiv
-9 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.10 kW
8.29 kW
COP Tj = -7°C
2.48
1.73
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.07 kW
6.40 kW
COP Tj = +2°C
4.36
3.08
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.25 kW
4.93 kW
COP Tj = +7°C
5.22
4.03
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.15 kW
5.91 kW
COP Tj = 12°C
6.59
5.40
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
10.51 kW
8.80 kW
COP Tj = Tbiv
2.25
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.24 kW
6.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.18
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.36 kW
5.75 kW
Annual energy consumption Qhe
5667 kWh
8259 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.81 kW
9.15 kW
El input
3.68 kW
3.62 kW
COP
3.75
2.53
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
217 %
147 %
Prated
13 kW
13 kW
SCOP
5.5
3.75
Tbiv
3 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.38 kW
9.82 kW
COP Tj = +2°C
2.77
2.07
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
8.1 kW
8.48 kW
COP Tj = +7°C
4.9
3.2
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
6.12 kW
5.73 kW
COP Tj = 12°C
7.02
4.91
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
11.74 kW
10.99 kW
COP Tj = Tbiv
2.93
2.41
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.38 kW
9.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.62 kW
3.18 kW
Annual energy consumption Qhe
3158 kWh
4627 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
131 %
103 %
Prated
11 kW
11 kW
SCOP
3.36
2.64
Tbiv
-15 °C
-12 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
6.25 kW
6.75 kW
COP Tj = -7°C
3.21
2.24
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.45 kW
4.22 kW
COP Tj = +2°C
4.26
3.43
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
5.19 kW
4.99 kW
COP Tj = +7°C
4.88
4.17
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.12 kW
5.96 kW
COP Tj = 12°C
7.02
5.55
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
9.35 kW
7.76 kW
COP Tj = Tbiv
2.02
1.7
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.35 kW
6.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.02
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11 kW
11 kW
Annual energy consumption Qhe
8067 kWh
10280 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.35
6.92
COP Tj = -15°C (if TOL<-20°C)
2.02
1.53
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
117 %
Prated
11.6 kW
12 kW
SCOP
4.23
3
Tbiv
-9 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.10 kW
8.29 kW
COP Tj = -7°C
2.48
1.73
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.07 kW
6.40 kW
COP Tj = +2°C
4.36
3.08
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.25 kW
4.93 kW
COP Tj = +7°C
5.22
4.03
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
6.15 kW
5.91 kW
COP Tj = 12°C
6.59
5.40
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
10.51 kW
8.80 kW
COP Tj = Tbiv
2.25
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.24 kW
6.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.18
1.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
1
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
0 W
0 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.36 kW
5.75 kW
Annual energy consumption Qhe
5667 kWh
8259 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
128 %
COP
3.09
Heating up time
01:33 h:min
Standby power input
41.7 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
264 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
79 %
COP
1.93
Heating up time
02:03 h:min
Standby power input
51.2 W
Reference hot water temperature
52.3 °C
Mixed water at 40°C
266 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
104 %
COP
2.52
Heating up time
01:46 h:min
Standby power input
48.3 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
265 l