4,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.48 kW
7.78 kW
El input
1.54 kW
2.44 kW
COP
5.60
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
144 %
Prated
11.10 kW
10.40 kW
SCOP
5.12
3.75
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.02 kW
9.23 kW
COP Tj = -7°C
3.30
2.41
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.29 kW
6.03 kW
COP Tj = +2°C
5.16
3.83
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.11 kW
3.72 kW
COP Tj = +7°C
6.51
4.47
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.93 kW
3.94 kW
COP Tj = 12°C
7.43
5.62
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.12 kW
10.61 kW
COP Tj = Tbiv
2.99
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.12 kW
10.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
67 °C
67 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4475 kWh
5734 kWh
Heating
EN 14511-2
Medium temperature
Heat output
7.78 kW
El input
2.44 kW
COP
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
0 dB(A)
Sound power level outdoor
46 dB(A)
EN 14825
Medium temperature
ηs
144 %
Prated
10.40 kW
SCOP
3.75
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
9.23 kW
COP Tj = -7°C
2.41
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
6.03 kW
COP Tj = +2°C
3.83
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
3.72 kW
COP Tj = +7°C
4.47
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
3.94 kW
COP Tj = 12°C
5.62
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
10.61 kW
COP Tj = Tbiv
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
67 °C
Poff
15 W
PTO
14 W
PSB
15 W
PCK
14 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
5734 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
127 %
COP
3.02
Heating up time
1:24 h:min
Standby power input
54.4 W
Reference hot water temperature
52.3 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.50 kW
7.81 kW
El input
1.53 kW
2.40 kW
COP
5.55
3.26
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
142 %
Prated
11.00 kW
10.30 kW
SCOP
5.21
3.67
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.78 kW
9.07 kW
COP Tj = -7°C
3.39
2.46
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.22 kW
5.82 kW
COP Tj = +2°C
5.17
3.71
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.90 kW
3.57 kW
COP Tj = +7°C
6.65
4.50
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.91 kW
3.73 kW
COP Tj = 12°C
7.71
5.29
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.99 kW
10.29 kW
COP Tj = Tbiv
3.11
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.99 kW
10.29 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
67 °C
67 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
12 W
12 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.01 kW
0.01 kW
Annual energy consumption Qhe
4365 kWh
5801 kWh
Heating
EN 14511-2
Medium temperature
Heat output
7.81 kW
El input
2.40 kW
COP
3.26
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
0 dB(A)
Sound power level outdoor
46 dB(A)
EN 14825
Medium temperature
ηs
142 %
Prated
10.30 kW
SCOP
3.67
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
9.07 kW
COP Tj = -7°C
2.46
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
5.82 kW
COP Tj = +2°C
3.71
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
3.57 kW
COP Tj = +7°C
4.50
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
3.73 kW
COP Tj = 12°C
5.29
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
10.29 kW
COP Tj = Tbiv
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.29 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
67 °C
Poff
12 W
PTO
12 W
PSB
12 W
PCK
12 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.01 kW
Annual energy consumption Qhe
5801 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
131 %
COP
3.12
Heating up time
1:24 h:min
Standby power input
51.2 W
Reference hot water temperature
52.2 °C
Mixed water at 40°C
238 l