Certificate holders

Subtype

ADAPT 0312

Certificate Holder
KRONOTERM d.o.o.
Trnava 5e
3303 Gomilsko
Slovenia
Registration number
011-1W0516
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ADAPT 0312
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R452B
Mass of Refrigerant

2,900 kg

Certification Date
18.01.2022
Testing basis
HP KEYMARK certification scheme rules rev. 9
Generate PDF Export model CSV
  • Number of models 4

Models

ADAPT 0312-K3 HT / HK 1F
Configure model
Model name
ADAPT 0312-K3 HT / HK 1F
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.08 kW

5.87 kW

El input

1.13 kW

1.91 kW

COP

5.45

3.08

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

44 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

139 %

Prated

8.10 kW

7.40 kW

SCOP

5.08

3.65

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.22 kW

6.37 kW

COP Tj = -7°C

3.35

2.43

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.60 kW

4.36 kW

COP Tj = +2°C

5.22

3.71

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.88 kW

2.78 kW

COP Tj = +7°C

6.13

4.45

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.77 kW

2.88 kW

COP Tj = 12°C

6.90

5.67

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.00 kW

7.40 kW

COP Tj = Tbiv

3.04

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.00 kW

7.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

67 °C

67 °C

Poff

14 W

14 W

PTO

14 W

14 W

PSB

14 W

14 W

PCK

14 W

14 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

3295 kWh

4192 kWh

ADAPT 0312-K3 HT / HK 1F + HYDRO C
Configure model
Model name
ADAPT 0312-K3 HT / HK 1F + HYDRO C
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

5.87 kW

El input

1.91 kW

COP

3.08

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

0 dB(A)

Sound power level outdoor

42 dB(A)

EN 14825

Medium temperature

ηs

139 %

Prated

7.40 kW

SCOP

3.65

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

6.37 kW

COP Tj = -7°C

2.43

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

4.36 kW

COP Tj = +2°C

3.71

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

2.78 kW

COP Tj = +7°C

4.45

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

2.88 kW

COP Tj = 12°C

5.67

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

7.41 kW

COP Tj = Tbiv

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

67 °C

Poff

14 W

PTO

14 W

PSB

14 W

PCK

14 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

4192 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.74

Heating up time

1:46 h:min

Standby power input

68.2 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

260 l

ADAPT 0312-K3 HT / HK 3F
Configure model
Model name
ADAPT 0312-K3 HT / HK 3F
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

5.87 kW

El input

1.12 kW

1.92 kW

COP

5.41

3.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

137 %

Prated

8.40 kW

7.80 kW

SCOP

4.93

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.30 kW

6.46 kW

COP Tj = -7°C

3.45

2.44

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.83 kW

4.48 kW

COP Tj = +2°C

4.87

3.72

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.04 kW

2.75 kW

COP Tj = +7°C

6.19

4.25

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.01 kW

2.92 kW

COP Tj = 12°C

7.19

5.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.05 kW

7.48 kW

COP Tj = Tbiv

3.11

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.05 kW

7.48 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.11

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

67 °C

67 °C

Poff

14 W

14 W

PTO

14 W

14 W

PSB

14 W

14 W

PCK

14 W

14 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.35 kW

0.32 kW

Annual energy consumption Qhe

3520 kWh

4510 kWh

ADAPT 0312-K3 HT / HK 3F + HYDRO C
Configure model
Model name
ADAPT 0312-K3 HT / HK 3F + HYDRO C
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

5.87 kW

El input

1.92 kW

COP

3.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

0 dB(A)

Sound power level outdoor

42 dB(A)

EN 14825

Medium temperature

ηs

137 %

Prated

7.80 kW

SCOP

3.57

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

6.46 kW

COP Tj = -7°C

2.44

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

4.48 kW

COP Tj = +2°C

3.72

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

2.75 kW

COP Tj = +7°C

4.25

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

2.92 kW

COP Tj = 12°C

5.36

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

7.48 kW

COP Tj = Tbiv

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

67 °C

Poff

14 W

PTO

14 W

PSB

14 W

PCK

14 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.32 kW

Annual energy consumption Qhe

4510 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

115 %

COP

2.73

Heating up time

1:46 h:min

Standby power input

69.0 W

Reference hot water temperature

55.4 °C

Mixed water at 40°C

261 l