Certificate holders

Subtype

Hi-Therma Monobloc 8kW

Certificate Holder
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd.
Qianwangang Road
266555 Qingdao, Shandong
China
Registration number
041-K021-04
Certification Body
BRE Global Limited
Subtype title
Hi-Therma Monobloc 8kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,210 kg

Certification Date
01.03.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AHZ-080HCDS1
Configure model
Model name
AHZ-080HCDS1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.63 kW

2.86 kW

COP

4.90

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

137 %

Prated

6.52 kW

6.07 kW

SCOP

5.00

3.50

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.74 kW

5.34 kW

COP Tj = -7°C

3.09

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.47 kW

3.11 kW

COP Tj = +2°C

4.76

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.44 kW

2.09 kW

COP Tj = +7°C

6.65

4.36

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.48 kW

1.23 kW

COP Tj = 12°C

9.58

6.52

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.74 kW

5.34 kW

COP Tj = Tbiv

3.09

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.14 kW

5.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

0.25 kW

Annual energy consumption Qhe

2680 kWh

3574 kWh