1,210 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
8.00 kW
El input
1.63 kW
2.86 kW
COP
4.90
2.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
137 %
Prated
6.52 kW
6.07 kW
SCOP
5.00
3.50
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.74 kW
5.34 kW
COP Tj = -7°C
3.09
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.47 kW
3.11 kW
COP Tj = +2°C
4.76
3.41
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.44 kW
2.09 kW
COP Tj = +7°C
6.65
4.36
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.48 kW
1.23 kW
COP Tj = 12°C
9.58
6.52
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.74 kW
5.34 kW
COP Tj = Tbiv
3.09
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.14 kW
5.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
11 W
11 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.37 kW
0.25 kW
Annual energy consumption Qhe
2680 kWh
3574 kWh