Certificate holders

Subtype

Hi-Therma Monobloc 4kW

Certificate Holder
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd.
Qianwangang Road
266555 Qingdao, Shandong
China
Registration number
041-K021-03
Certification Body
BRE Global Limited
Subtype title
Hi-Therma Monobloc 4kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,170 kg

Certification Date
01.03.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AHZ-044HCDS1
Configure model
Model name
AHZ-044HCDS1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.40 kW

4.40 kW

El input

0.86 kW

1.47 kW

COP

5.10

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

136 %

Prated

4.61 kW

4.09 kW

SCOP

5.17

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.05 kW

3.60 kW

COP Tj = -7°C

3.26

2.08

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.48 kW

2.26 kW

COP Tj = +2°C

5.02

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.67 kW

1.49 kW

COP Tj = +7°C

6.70

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.14 kW

1.02 kW

COP Tj = 12°C

8.74

6.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.05 kW

3.60 kW

COP Tj = Tbiv

3.26

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.56 kW

3.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

7 W

7 W

PTO

8 W

8 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.48 kW

Annual energy consumption Qhe

1830 kWh

2425 kWh