Certificate holders

Subtype

DAIKIN ALTHERMA 3 WS 6KW

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0520
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 WS 6KW
Driving energy
Electricity
Heat Pump Type
Water/Water
Refrigerant
R32
Mass of Refrigerant

1,700 kg

Certification Date
14.02.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9 (as of 2021-03)
Generate PDF Export model CSV
  • Number of models 4

Models

EWSAH06DA9W
Configure model
Model name
EWSAH06DA9W
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.13 kW

5.61 kW

El input

1.15 kW

1.72 kW

COP

5.33

3.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.38 kW

Cooling capacity

5.81

EER

4.21

EN 14825

+7°C/+12°C

Pdesignc

5.81 kW

SEER

6.98

Pdc Tj = 35°C

5.81 kW

EER Tj = 35°C

4.21

Pdc Tj = 30°C

4.54 kW

EER Tj = 30°C

5.82

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

2.77 kW

EER Tj = 25°C

8.83

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

3.12 kW

EER Tj = 20°C

10.41

Cdc Tj = 20 °C

0.950

Poff

15 W

PTO

24 W

PSB

15 W

PCK

0 W

Annual energy consumption Qce

500 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

162 %

Prated

6.10 kW

5.60 kW

SCOP

6.06

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.13 kW

5.61 kW

COP Tj = +2°C

5.33

3.27

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.85 kW

3.53 kW

COP Tj = +7°C

6.14

3.93

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

1.67 kW

1.66 kW

COP Tj = 12°C

6.92

5.17

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1345 kWh

1766 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

166 %

Prated

6.05 kW

5.60 kW

SCOP

5.05

4.36

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.47 kW

3.68 kW

COP Tj = -7°C

6.68

4.26

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.04 kW

2.06 kW

COP Tj = +2°C

7.26

4.86

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.31 kW

1.28 kW

COP Tj = +7°C

6.97

4.03

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

0.99 kW

0.95 kW

COP Tj = 12°C

6.99

4.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3169 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

252 %

158 %

Prated

6.10 kW

5.60 kW

SCOP

6.49

4.15

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.20 kW

4.83 kW

COP Tj = -7°C

5.49

3.50

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.47 kW

3.13 kW

COP Tj = +2°C

6.68

4.46

Cdh Tj = +2 °C

0.900

1.000

Pdh Tj = +7°C

2.16 kW

1.92 kW

COP Tj = +7°C

7.66

5.10

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

0.99 kW

0.80 kW

COP Tj = 12°C

6.99

4.28

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1941 kWh

2785 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EWSAH06UDA9W
Configure model
Model name
EWSAH06UDA9W
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.13 kW

5.61 kW

El input

1.15 kW

1.72 kW

COP

5.33

3.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.38 kW

Cooling capacity

5.81

EER

4.21

EN 14825

+7°C/+12°C

Pdesignc

5.81 kW

SEER

6.98

Pdc Tj = 35°C

5.81 kW

EER Tj = 35°C

4.21

Pdc Tj = 30°C

4.54 kW

EER Tj = 30°C

5.82

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

2.77 kW

EER Tj = 25°C

8.83

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

3.12 kW

EER Tj = 20°C

10.41

Cdc Tj = 20 °C

0.950

Poff

15 W

PTO

24 W

PSB

15 W

PCK

0 W

Annual energy consumption Qce

500 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

162 %

Prated

6.10 kW

5.60 kW

SCOP

6.06

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.13 kW

5.61 kW

COP Tj = +2°C

5.33

3.27

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.85 kW

3.53 kW

COP Tj = +7°C

6.14

3.93

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

1.67 kW

1.66 kW

COP Tj = 12°C

6.92

5.17

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1345 kWh

1766 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

166 %

Prated

6.05 kW

5.60 kW

SCOP

5.05

4.36

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.47 kW

3.68 kW

COP Tj = -7°C

6.68

4.26

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.04 kW

2.06 kW

COP Tj = +2°C

7.26

4.86

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.31 kW

1.28 kW

COP Tj = +7°C

6.97

4.03

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

0.99 kW

0.95 kW

COP Tj = 12°C

6.99

4.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3169 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

252 %

158 %

Prated

6.10 kW

5.60 kW

SCOP

6.49

4.15

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.20 kW

4.83 kW

COP Tj = -7°C

5.49

3.50

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.47 kW

3.13 kW

COP Tj = +2°C

6.68

4.46

Cdh Tj = +2 °C

0.900

1.000

Pdh Tj = +7°C

2.16 kW

1.92 kW

COP Tj = +7°C

7.66

5.10

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

0.99 kW

0.80 kW

COP Tj = 12°C

6.99

4.28

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1941 kWh

2785 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EWSAX06DA9W
Configure model
Model name
EWSAX06DA9W
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.13 kW

5.61 kW

El input

1.15 kW

1.72 kW

COP

5.33

3.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.38 kW

Cooling capacity

5.81

EER

4.21

EN 14825

+7°C/+12°C

Pdesignc

5.81 kW

SEER

6.98

Pdc Tj = 35°C

5.81 kW

EER Tj = 35°C

4.21

Pdc Tj = 30°C

4.54 kW

EER Tj = 30°C

5.82

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

2.77 kW

EER Tj = 25°C

8.83

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

3.12 kW

EER Tj = 20°C

10.41

Cdc Tj = 20 °C

0.950

Poff

15 W

PTO

24 W

PSB

15 W

PCK

0 W

Annual energy consumption Qce

500 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

168 %

Prated

6.10 kW

5.60 kW

SCOP

6.37

4.40

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.13 kW

5.61 kW

COP Tj = +2°C

5.33

3.27

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.85 kW

3.53 kW

COP Tj = +7°C

6.14

3.93

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

1.67 kW

1.66 kW

COP Tj = 12°C

6.92

5.17

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1279 kWh

1699 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

168 %

Prated

6.05 kW

5.60 kW

SCOP

5.11

4.40

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.47 kW

3.68 kW

COP Tj = -7°C

6.68

4.26

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.04 kW

2.06 kW

COP Tj = +2°C

7.26

4.86

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.31 kW

1.28 kW

COP Tj = +7°C

6.97

4.03

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

0.99 kW

0.95 kW

COP Tj = 12°C

6.99

4.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2919 kWh

3138 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

162 %

Prated

6.10 kW

5.60 kW

SCOP

6.68

4.24

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.20 kW

4.83 kW

COP Tj = -7°C

5.49

3.50

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.47 kW

3.13 kW

COP Tj = +2°C

6.68

4.46

Cdh Tj = +2 °C

0.900

1.000

Pdh Tj = +7°C

2.16 kW

1.92 kW

COP Tj = +7°C

7.66

5.10

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

0.99 kW

0.80 kW

COP Tj = 12°C

6.99

4.28

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1886 kWh

2730 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EWSAX06UDA9W
Configure model
Model name
EWSAX06UDA9W
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.13 kW

5.61 kW

El input

1.15 kW

1.72 kW

COP

5.33

3.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.38 kW

Cooling capacity

5.81

EER

4.21

EN 14825

+7°C/+12°C

Pdesignc

5.81 kW

SEER

6.98

Pdc Tj = 35°C

5.81 kW

EER Tj = 35°C

4.21

Pdc Tj = 30°C

4.54 kW

EER Tj = 30°C

5.82

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

2.77 kW

EER Tj = 25°C

8.83

Cdc Tj = 25 °C

0.950

Pdc Tj = 20°C

3.12 kW

EER Tj = 20°C

10.41

Cdc Tj = 20 °C

0.950

Poff

15 W

PTO

24 W

PSB

15 W

PCK

0 W

Annual energy consumption Qce

500 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

168 %

Prated

6.10 kW

5.60 kW

SCOP

6.37

4.40

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.13 kW

5.61 kW

COP Tj = +2°C

5.33

3.27

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.85 kW

3.53 kW

COP Tj = +7°C

6.14

3.93

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

1.67 kW

1.66 kW

COP Tj = 12°C

6.92

5.17

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1279 kWh

1699 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

168 %

Prated

6.05 kW

5.60 kW

SCOP

5.11

4.40

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.47 kW

3.68 kW

COP Tj = -7°C

6.68

4.26

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.04 kW

2.06 kW

COP Tj = +2°C

7.26

4.86

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.31 kW

1.28 kW

COP Tj = +7°C

6.97

4.03

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

0.99 kW

0.95 kW

COP Tj = 12°C

6.99

4.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2919 kWh

3138 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

162 %

Prated

6.10 kW

5.60 kW

SCOP

6.68

4.24

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.20 kW

4.83 kW

COP Tj = -7°C

5.49

3.50

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.47 kW

3.13 kW

COP Tj = +2°C

6.68

4.46

Cdh Tj = +2 °C

0.900

1.000

Pdh Tj = +7°C

2.16 kW

1.92 kW

COP Tj = +7°C

7.66

5.10

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

0.99 kW

0.80 kW

COP Tj = 12°C

6.99

4.28

Cdh Tj = +12 °C

0.900

1.000

Pdh Tj = Tbiv

6.13 kW

5.61 kW

COP Tj = Tbiv

5.33

3.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.13 kW

5.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.33

3.27

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1886 kWh

2730 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.77

Heating up time

1:48 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l