Certificate holders

Subtype

VERSI 0209

Certificate Holder
KRONOTERM d.o.o.
Trnava 5e
3303 Gomilsko
Slovenia
Registration number
011-1W0519
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
VERSI 0209
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R452B
Mass of Refrigerant

1,500 kg

Certification Date
18.01.2022
Testing basis
HP KEYMARK certification scheme rules rev. 9
Generate PDF Export model CSV
  • Number of models 6

Models

VERSI-I 0209-K1 HT / HK UF E
Configure model
Model name
VERSI-I 0209-K1 HT / HK UF E
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.13 kW

6.09 kW

El input

1.28 kW

1.95 kW

COP

4.80

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

42 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

141 %

Prated

6.50 kW

6.10 kW

SCOP

4.84

3.66

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.76 kW

5.46 kW

COP Tj = -7°C

3.05

2.32

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.57 kW

3.30 kW

COP Tj = +2°C

5.01

3.71

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.45 kW

2.20 kW

COP Tj = +7°C

5.79

4.30

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

2.72 kW

2.53 kW

COP Tj = 12°C

6.62

5.82

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.20 kW

6.07 kW

COP Tj = Tbiv

2.78

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.20 kW

6.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

67 °C

67 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.03 kW

Annual energy consumption Qhe

2773 kWh

3441 kWh

VERSI-X 0209-K1 HT / HK 1F
Configure model
Model name
VERSI-X 0209-K1 HT / HK 1F
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.13 kW

6.09 kW

El input

1.28 kW

1.95 kW

COP

4.80

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

42 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

141 %

Prated

6.50 kW

6.10 kW

SCOP

4.84

3.66

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.76 kW

5.46 kW

COP Tj = -7°C

3.05

2.32

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.57 kW

3.30 kW

COP Tj = +2°C

5.01

3.71

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.45 kW

2.20 kW

COP Tj = +7°C

5.79

4.30

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.72 kW

2.53 kW

COP Tj = 12°C

6.62

5.82

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.20 kW

6.07 kW

COP Tj = Tbiv

2.78

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.20 kW

6.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

67 °C

67 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.03 kW

Annual energy consumption Qhe

2773 kWh

3441 kWh

VERSI-O 0209-K1 HT / HK 1F
Configure model
Model name
VERSI-O 0209-K1 HT / HK 1F
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.20 kW

6.04 kW

El input

1.24 kW

1.93 kW

COP

5.01

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

43 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

138 %

Prated

6.40 kW

6.00 kW

SCOP

4.97

3.60

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.71 kW

5.38 kW

COP Tj = -7°C

3.26

2.21

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.74 kW

3.51 kW

COP Tj = +2°C

5.25

3.56

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.27 kW

2.20 kW

COP Tj = +7°C

5.55

4.54

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.36 kW

2.40 kW

COP Tj = 12°C

6.65

5.85

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.11 kW

5.88 kW

COP Tj = Tbiv

2.76

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.11 kW

5.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

67 °C

67 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.29 kW

0.12 kW

Annual energy consumption Qhe

2659 kWh

3446 kWh

VERSI-O 0209-K1 HT / HK 1F + HYDRO C2
Configure model
Model name
VERSI-O 0209-K1 HT / HK 1F + HYDRO C2
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

6.04 kW

El input

1.93 kW

COP

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

0 dB(A)

Sound power level outdoor

44 dB(A)

EN 14825

Medium temperature

ηs

138 %

Prated

6.00 kW

SCOP

3.60

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

5.38 kW

COP Tj = -7°C

2.21

Cdh Tj = -7 °C

1.000

Pdh Tj = +2°C

3.51 kW

COP Tj = +2°C

3.56

Cdh Tj = +2 °C

0.990

Pdh Tj = +7°C

2.20 kW

COP Tj = +7°C

4.54

Cdh Tj = +7 °C

0.980

Pdh Tj = 12°C

2.40 kW

COP Tj = 12°C

5.85

Cdh Tj = +12 °C

0.980

Pdh Tj = Tbiv

5.88 kW

COP Tj = Tbiv

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

WTOL

67 °C

Poff

8 W

PTO

8 W

PSB

8 W

PCK

8 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.12 kW

Annual energy consumption Qhe

3446 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

97 %

COP

2.30

Heating up time

2:35 h:min

Standby power input

47.4 W

Reference hot water temperature

54.5 °C

Mixed water at 40°C

264 l

VERSI-X 0209-K1 HT / HK 1F + HYDRO C2
Configure model
Model name
VERSI-X 0209-K1 HT / HK 1F + HYDRO C2
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

6.09 kW

El input

1.95 kW

COP

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

42 dB(A)

Sound power level outdoor

45 dB(A)

EN 14825

Medium temperature

ηs

141 %

Prated

6.10 kW

SCOP

3.66

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

5.46 kW

COP Tj = -7°C

2.32

Cdh Tj = -7 °C

1.000

Pdh Tj = +2°C

3.30 kW

COP Tj = +2°C

3.71

Cdh Tj = +2 °C

0.990

Pdh Tj = +7°C

2.20 kW

COP Tj = +7°C

4.30

Cdh Tj = +7 °C

0.980

Pdh Tj = 12°C

2.53 kW

COP Tj = 12°C

5.82

Cdh Tj = +12 °C

0.980

Pdh Tj = Tbiv

6.07 kW

COP Tj = Tbiv

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

WTOL

67 °C

Poff

8 W

PTO

8 W

PSB

8 W

PCK

8 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.03 kW

Annual energy consumption Qhe

3441 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

96 %

COP

2.30

Heating up time

2:18 h:min

Standby power input

41.0 W

Reference hot water temperature

54.4 °C

Mixed water at 40°C

255 l

VERSI-I 0209-K1 HT / HK UF E + HR200
Configure model
Model name
VERSI-I 0209-K1 HT / HK UF E + HR200
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

6.09 kW

El input

1.95 kW

COP

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

42 dB(A)

Sound power level outdoor

45 dB(A)

EN 14825

Medium temperature

ηs

141 %

Prated

6.10 kW

SCOP

3.66

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

5.46 kW

COP Tj = -7°C

2.32

Cdh Tj = -7 °C

1.000

Pdh Tj = +2°C

3.30 kW

COP Tj = +2°C

3.71

Cdh Tj = +2 °C

0.990

Pdh Tj = +7°C

2.20 kW

COP Tj = +7°C

4.30

Cdh Tj = +7 °C

0.980

Pdh Tj = 12°C

2.53 kW

COP Tj = 12°C

5.82

Cdh Tj = +12 °C

0.980

Pdh Tj = Tbiv

6.07 kW

COP Tj = Tbiv

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

WTOL

67 °C

Poff

8 W

PTO

8 W

PSB

8 W

PCK

8 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.03 kW

Annual energy consumption Qhe

3441 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.38

Heating up time

2:27 h:min

Standby power input

44.9 W

Reference hot water temperature

54.9 °C

Mixed water at 40°C

282 l