Certificate holders

Subtype

DAIKIN ALTHERMA M HW 260L

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0522
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA M HW 260L
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R134a
Mass of Refrigerant

1,000 kg

Certification Date
14.03.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9 (as of 2021-03)
Generate PDF Export model CSV
  • Number of models 2

Models

EKHHE260CV37
Configure model
Model name
EKHHE260CV37
Units
Indoor
Climate zone (for heating)
Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

160 %

COP

3.90

Heating up time

7:54 h:min

Standby power input

24.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

340 l

Average Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

138 %

COP

3.37

Heating up time

9:29 h:min

Standby power input

28.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

340 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

EKHHE260PCV37
Configure model
Model name
EKHHE260PCV37
Units
Indoor
Climate zone (for heating)
Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

160 %

COP

3.90

Heating up time

7:54 h:min

Standby power input

24.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

333 l

Average Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

138 %

COP

3.37

Heating up time

9:29 h:min

Standby power input

28.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

333 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed