DAIKIN ALTHERMA 3 H MT F+W 08KW (180L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0506
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 H MT F+W 08KW (180L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,250 kg

Certification Date
24.11.2021
Testing basis
HP KEYMARK certification scheme rules rev. 9
Generate PDF Export model CSV
  • Number of models 18

Models

EPRA08EV3 / ETBH12E(6V/9W)
Configure model
Model name
EPRA08EV3 / ETBH12E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

134 %

Prated

8.30 kW

8.50 kW

SCOP

4.69

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.60 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.40 kW

4.60 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.30 kW

3.00 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.60 kW

3.70 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.50 kW

7.60 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

1.50 kW

Annual energy consumption Qhe

3659 kWh

5142 kWh

EPRA08EV3 / ETBX12E(6V/9W)
Configure model
Model name
EPRA08EV3 / ETBX12E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.50 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.940

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.910

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

136 %

Prated

8.30 kW

8.50 kW

SCOP

4.79

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.60 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.40 kW

4.60 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.30 kW

3.00 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.60 kW

3.70 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.50 kW

7.60 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

1.50 kW

Annual energy consumption Qhe

3582 kWh

5065 kWh

EPRA08EV3 / ETVH12S18E(6V/9W)
Configure model
Model name
EPRA08EV3 / ETVH12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

134 %

Prated

8.3 kW

8.5 kW

SCOP

4.69

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3659 kWh

5142 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EV3 / ETVH12SU18E6V
Configure model
Model name
EPRA08EV3 / ETVH12SU18E6V
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

134 %

Prated

8.3 kW

8.5 kW

SCOP

4.69

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3659 kWh

5142 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EV3 / ETVX12S18E(6V/9W)
Configure model
Model name
EPRA08EV3 / ETVX12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

136 %

Prated

8.3 kW

8.5 kW

SCOP

4.79

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3582 kWh

5065 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EV3 / ETVZ12S18E(6V/9W)
Configure model
Model name
EPRA08EV3 / ETVZ12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

134 %

Prated

8.3 kW

8.5 kW

SCOP

4.69

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3659 kWh

5142 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EW1 / ETBH12E(6V/9W)
Configure model
Model name
EPRA08EW1 / ETBH12E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.97

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

138 %

Prated

8.3 kW

8.5 kW

SCOP

4.81

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3561 kWh

4993 kWh

EPRA08EW1 / ETBX12E(6V/9W)
Configure model
Model name
EPRA08EW1 / ETBX12E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.97

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.95

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3462 kWh

4894 kWh

EPRA08EW1 / ETVH12S18E(6V/9W)
Configure model
Model name
EPRA08EW1 / ETVH12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.97

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

138 %

Prated

8.3 kW

8.5 kW

SCOP

4.81

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3561 kWh

4993 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EW1 / ETVH12SU18E6V
Configure model
Model name
EPRA08EW1 / ETVH12SU18E6V
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.97

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

138 %

Prated

8.3 kW

8.5 kW

SCOP

4.81

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3561 kWh

4993 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EW1 / ETVX12S18E(6V/9W)
Configure model
Model name
EPRA08EW1 / ETVX12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.50 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.970

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.940

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.910

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.95

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3462 kWh

4894 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EW1 / ETVZ12S18E(6V/9W)
Configure model
Model name
EPRA08EW1 / ETVZ12S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.97

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

138 %

Prated

8.3 kW

8.5 kW

SCOP

4.81

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3561 kWh

4993 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EV3 / ETBH12E(6V/9W) + cooling kit
Configure model
Model name
EPRA08EV3 / ETBH12E(6V/9W) + cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.50 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.980

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.940

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.910

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

136 %

Prated

8.30 kW

8.50 kW

SCOP

4.79

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.60 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.40 kW

4.60 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.30 kW

3.00 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.60 kW

3.70 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.50 kW

7.60 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

1.50 kW

Annual energy consumption Qhe

3582 kWh

5065 kWh

EPRA08EV3 / ETVH12S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA08EV3 / ETVH12S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

136 %

Prated

8.3 kW

8.5 kW

SCOP

4.79

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3582 kWh

5065 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EW1 / ETBH12E(6V/9W) + cooling kit
Configure model
Model name
EPRA08EW1 / ETBH12E(6V/9W) + cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.97

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.91

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.95

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3462 kWh

4894 kWh

EPRA08EW1 / ETVH12S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA08EW1 / ETVH12S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.50 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.970

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.940

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.910

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.95

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3462 kWh

4894 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EV3 / ETVZ12S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA08EV3 / ETVZ12S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.25 kW

2.63 kW

COP

4.92

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.15 kW

Cooling capacity

6.81

EER

3.17

EN 14825

+7°C/+12°C

Pdesignc

6.5 kW

SEER

5.38

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.17

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.37

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.58

Cdc Tj = 25 °C

0.94

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

8.00

Cdc Tj = 20 °C

0.91

Poff

25 W

PTO

3 W

PSB

25 W

PCK

0 W

Annual energy consumption Qce

725 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

136 %

Prated

8.3 kW

8.5 kW

SCOP

4.79

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.10

2.21

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.76

3.37

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.14

4.48

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

7.84

5.98

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.10

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

24 W

24 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3582 kWh

5065 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.72

Heating up time

1:57 h:min

Standby power input

51.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA08EW1 / ETVZ12S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA08EW1 / ETVZ12S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.17 kW

7.72 kW

El input

1.21 kW

2.53 kW

COP

5.10

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.08 kW

Cooling capacity

6.81

EER

3.28

EN 14825

+7°C/+12°C

Pdesignc

6.50 kW

SEER

5.41

Pdc Tj = 35°C

6.81 kW

EER Tj = 35°C

3.28

Pdc Tj = 30°C

5.00 kW

EER Tj = 30°C

4.52

Cdc Tj = 30 °C

0.970

Pdc Tj = 25°C

3.01 kW

EER Tj = 25°C

6.66

Cdc Tj = 25 °C

0.940

Pdc Tj = 20°C

2.57 kW

EER Tj = 20°C

7.98

Cdc Tj = 20 °C

0.910

Poff

31 W

PTO

0 W

PSB

31 W

PCK

0 W

Annual energy consumption Qce

719 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

53.0 dB(A)

53.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

8.3 kW

8.5 kW

SCOP

4.95

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.5 kW

7.6 kW

COP Tj = -7°C

3.20

2.30

Cdh Tj = -7 °C

1.0

1.0

Pdh Tj = +2°C

4.4 kW

4.6 kW

COP Tj = +2°C

4.93

3.50

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.3 kW

3.0 kW

COP Tj = +7°C

6.37

4.61

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

6.6 kW

3.7 kW

COP Tj = 12°C

8.13

6.16

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

7.5 kW

7.6 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.0 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.01

WTOL

35 °C

55 °C

Poff

27 W

27 W

PTO

24 W

24 W

PSB

27 W

27 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

1.5 kW

Annual energy consumption Qhe

3462 kWh

4894 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.80

Heating up time

1:57 h:min

Standby power input

50.7 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l