DAIKIN ALTHERMA 3 R F+W 16KW (180L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0500
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 R F+W 16KW (180L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,800 kg

Certification Date
10.11.2021
Testing basis
HP KEYMARK certification scheme rules rev. 8
Generate PDF Export model CSV
  • Number of models 16

Models

ERLA16DV3 / EBBH16D(6V/9W)
Configure model
Model name
ERLA16DV3 / EBBH16D(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

12.0 kW

12.1 kW

SCOP

5.99

4.26

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2675 kWh

3792 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

130 %

Prated

12.0 kW

12.0 kW

SCOP

4.61

3.32

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5377 kWh

7477 kWh

ERLA16DV3 / EBBH16D(6V/9W) + cooling kit
Configure model
Model name
ERLA16DV3 / EBBH16D(6V/9W) + cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

ERLA16DV3 / EBBX16D(6V/9W)
Configure model
Model name
ERLA16DV3 / EBBX16D(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

ERLA16DV3 / EBVH16S18D(6V/9W)
Configure model
Model name
ERLA16DV3 / EBVH16S18D(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

12.0 kW

12.1 kW

SCOP

5.99

4.26

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2675 kWh

3792 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

130 %

Prated

12.0 kW

12.0 kW

SCOP

4.61

3.32

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5377 kWh

7477 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DV3 / EBVH16S18D(6V/9W) + cooling kit
Configure model
Model name
ERLA16DV3 / EBVH16S18D(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DV3 / EBVX16S18D(6V/9W)
Configure model
Model name
ERLA16DV3 / EBVX16S18D(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DV3 / EBVZ16S18D(6V/9W)
Configure model
Model name
ERLA16DV3 / EBVZ16S18D(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

12.0 kW

12.1 kW

SCOP

5.99

4.26

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2675 kWh

3792 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

130 %

Prated

12.0 kW

12.0 kW

SCOP

4.61

3.32

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5377 kWh

7477 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DV3 / EBVZ16S18D(6V/9W) + cooling kit
Configure model
Model name
ERLA16DV3 / EBVZ16S18D(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DW1 / EBBH16D(6V/9W)
Configure model
Model name
ERLA16DW1 / EBBH16D(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

12.0 kW

12.1 kW

SCOP

5.99

4.26

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2675 kWh

3792 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

130 %

Prated

12.0 kW

12.0 kW

SCOP

4.61

3.32

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5377 kWh

7477 kWh

ERLA16DW1 / EBBH16D(6V/9W) + cooling kit
Configure model
Model name
ERLA16DW1 / EBBH16D(6V/9W) + cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

ERLA16DW1 / EBBX16D(6V/9W)
Configure model
Model name
ERLA16DW1 / EBBX16D(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

ERLA16DW1 / EBVH16S18D(6V/9W)
Configure model
Model name
ERLA16DW1 / EBVH16S18D(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

12.0 kW

12.1 kW

SCOP

5.99

4.26

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2675 kWh

3792 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

130 %

Prated

12.0 kW

12.0 kW

SCOP

4.61

3.32

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5377 kWh

7477 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DW1 / EBVH16S18D(6V/9W) + cooling kit
Configure model
Model name
ERLA16DW1 / EBVH16S18D(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DW1 / EBVX16S18D(6V/9W)
Configure model
Model name
ERLA16DW1 / EBVX16S18D(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DW1 / EBVZ16S18D(6V/9W)
Configure model
Model name
ERLA16DW1 / EBVZ16S18D(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

168 %

Prated

12.0 kW

12.1 kW

SCOP

5.99

4.26

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2675 kWh

3792 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

130 %

Prated

12.0 kW

12.0 kW

SCOP

4.61

3.32

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5377 kWh

7477 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

ERLA16DW1 / EBVZ16S18D(6V/9W) + cooling kit
Configure model
Model name
ERLA16DW1 / EBVZ16S18D(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.63 kW

El input

3.53 kW

5.68 kW

COP

4.53

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

4.68 kW

Cooling capacity

13.63

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

13.60 kW

SEER

5.76

Pdc Tj = 35°C

13.60 kW

EER Tj = 35°C

2.88

Pdc Tj = 30°C

9.70 kW

EER Tj = 30°C

4.58

Cdc Tj = 30 °C

0.990

Pdc Tj = 25°C

6.20 kW

EER Tj = 25°C

6.99

Cdc Tj = 25 °C

0.980

Pdc Tj = 20°C

6.20 kW

EER Tj = 20°C

6.99

Cdc Tj = 20 °C

0.980

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

1417 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

12.0 kW

12.1 kW

SCOP

6.23

4.38

Tbiv

2 °C

3 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.9 kW

9.8 kW

COP Tj = +2°C

3.30

2.17

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

8.1 kW

7.6 kW

COP Tj = +7°C

5.64

3.83

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.2 kW

5.0 kW

COP Tj = 12°C

7.73

5.69

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.9 kW

11.0 kW

COP Tj = Tbiv

3.30

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.92 kW

9.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.30

2.17

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

2.27 kW

Annual energy consumption Qhe

2573 kWh

3690 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44.0 dB(A)

44.0 dB(A)

Sound power level outdoor

62.0 dB(A)

62.0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

12.0 kW

12.0 kW

SCOP

4.68

3.35

Tbiv

-8 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.2 kW

9.40 kW

COP Tj = -7°C

2.87

1.95

Cdh Tj = -7 °C

n/a

1.0

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.33

3.27

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.83

4.93

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.82

6.60

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

11.4 kW

10.1 kW

COP Tj = Tbiv

2.72

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.6 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.50

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

6.10 kW

Annual energy consumption Qhe

5293 kWh

7392 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.26

Heating up time

1:16 h:min

Standby power input

38.4 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.73

Heating up time

1:21 h:min

Standby power input

42.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

244.0 l