Certificate holders

Subtype

Áurea+ HP60 10/12 / AHP60 10/12

Certificate Holder
Group Atlantic España - Soluciones Confort Térmico S.A.
Calle Antonio Machado, 65 - Edificio Sócrates
08840 Viladecans, Barcelona
Spain
Registration number
ICIM-PDC-000123-00
Certification Body
ICIM S.p.A.
Subtype title
Áurea+ HP60 10/12 / AHP60 10/12
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,500 kg

Certification Date
18.10.2021
Testing basis
HP KEYMARK certification scheme rules rev. no. 7
Generate PDF Export model CSV Download certificate
  • Number of models 6

Models

HP60-12 / AHP60-12
Configure model
Model name
HP60-12 / AHP60-12
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Cooling

EN 14511-2

+7°C/+12°C

El input

2.79 kW

Cooling capacity

8.51

EER

3.05

EN 14825

+7°C/+12°C

Pdesignc

8.51 kW

SEER

4.25

Pdc Tj = 35°C

8.51 kW

EER Tj = 35°C

3.05

Pdc Tj = 30°C

6.28 kW

EER Tj = 30°C

4.03

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

3.98 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

4.23 kW

EER Tj = 20°C

6.32

Cdc Tj = 20 °C

1.0

Poff

19 W

PTO

0 W

PSB

19 W

PCK

30 W

Annual energy consumption Qce

1202 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.80 kW

11.37 kW

El input

2.73 kW

4.10 kW

COP

4.32

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

131 %

Prated

10.00 kW

10.00 kW

SCOP

4.47

3.36

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.90 kW

8.50 kW

COP Tj = -7°C

2.88

2.08

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.40 kW

5.20 kW

COP Tj = +2°C

4.31

3.35

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

5.82

4.24

Cdh Tj = +7 °C

0.974

0.980

Pdh Tj = 12°C

4.90 kW

4.80 kW

COP Tj = 12°C

7.81

5.31

Cdh Tj = +12 °C

0.969

0.980

Pdh Tj = Tbiv

8.90 kW

8.50 kW

COP Tj = Tbiv

2.88

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.80 kW

8.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.96

WTOL

60 °C

60 °C

Poff

19 W

19 W

PTO

22 W

22 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4630 kWh

5941 kWh

HP60-10 / AHP60-10
Configure model
Model name
HP60-10 / AHP60-10
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Cooling

EN 14511-2

+7°C/+12°C

El input

2.39 kW

Cooling capacity

7.53

EER

3.15

EN 14825

+7°C/+12°C

Pdesignc

7.53 kW

SEER

4.15

Pdc Tj = 35°C

7.53 kW

EER Tj = 35°C

3.15

Pdc Tj = 30°C

5.49 kW

EER Tj = 30°C

3.92

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

3.56 kW

EER Tj = 25°C

4.46

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

4.35 kW

EER Tj = 20°C

6.36

Cdc Tj = 20 °C

1.0

Poff

19 W

PTO

0 W

PSB

19 W

PCK

30 W

Annual energy consumption Qce

1089 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.10 kW

9.73 kW

El input

2.28 kW

3.50 kW

COP

4.43

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

135 %

Prated

9.00 kW

9.00 kW

SCOP

4.53

3.45

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.30 kW

8.10 kW

COP Tj = -7°C

2.93

2.13

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.30 kW

5.20 kW

COP Tj = +2°C

4.32

3.41

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.20 kW

4.10 kW

COP Tj = +7°C

6.01

4.30

Cdh Tj = +7 °C

0.973

0.980

Pdh Tj = 12°C

4.90 kW

4.80 kW

COP Tj = 12°C

8.08

6.36

Cdh Tj = +12 °C

0.969

0.975

Pdh Tj = Tbiv

8.30 kW

8.10 kW

COP Tj = Tbiv

2.93

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.30 kW

8.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.96

WTOL

60 °C

60 °C

Poff

19 W

19 W

PTO

22 W

22 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4293 kWh

5462 kWh

HP60-10TR / AHP60-10TR
Configure model
Model name
HP60-10TR / AHP60-10TR
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Cooling

EN 14511-2

+7°C/+12°C

El input

2.39 kW

Cooling capacity

7.53

EER

3.15

EN 14825

+7°C/+12°C

Pdesignc

7.53 kW

SEER

4.15

Pdc Tj = 35°C

7.53 kW

EER Tj = 35°C

3.15

Pdc Tj = 30°C

5.49 kW

EER Tj = 30°C

3.92

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

3.56 kW

EER Tj = 25°C

4.46

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

4.35 kW

EER Tj = 20°C

6.36

Cdc Tj = 20 °C

1.0

Poff

19 W

PTO

0 W

PSB

19 W

PCK

30 W

Annual energy consumption Qce

1089 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.10 kW

9.73 kW

El input

2.28 kW

3.50 kW

COP

4.43

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

135 %

Prated

9.00 kW

9.00 kW

SCOP

4.53

3.45

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.30 kW

8.10 kW

COP Tj = -7°C

2.93

2.13

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.30 kW

5.20 kW

COP Tj = +2°C

4.32

3.41

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.20 kW

4.10 kW

COP Tj = +7°C

6.01

4.30

Cdh Tj = +7 °C

0.973

0.980

Pdh Tj = 12°C

4.90 kW

4.80 kW

COP Tj = 12°C

8.08

6.36

Cdh Tj = +12 °C

0.969

0.975

Pdh Tj = Tbiv

8.30 kW

8.10 kW

COP Tj = Tbiv

2.93

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.30 kW

8.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.96

WTOL

60 °C

60 °C

Poff

19 W

19 W

PTO

22 W

22 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4293 kWh

5462 kWh

HP60-12TR / AHP60-12TR
Configure model
Model name
HP60-12TR / AHP60-12TR
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Cooling

EN 14511-2

+7°C/+12°C

El input

2.79 kW

Cooling capacity

8.51

EER

3.05

EN 14825

+7°C/+12°C

Pdesignc

8.51 kW

SEER

4.25

Pdc Tj = 35°C

8.51 kW

EER Tj = 35°C

3.05

Pdc Tj = 30°C

6.28 kW

EER Tj = 30°C

4.03

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

3.98 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

4.23 kW

EER Tj = 20°C

6.32

Cdc Tj = 20 °C

1.0

Poff

19 W

PTO

0 W

PSB

19 W

PCK

30 W

Annual energy consumption Qce

1202 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.80 kW

11.37 kW

El input

2.73 kW

4.10 kW

COP

4.32

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

131 %

Prated

10.00 kW

10.00 kW

SCOP

4.47

3.36

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.90 kW

8.50 kW

COP Tj = -7°C

2.88

2.08

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.40 kW

5.20 kW

COP Tj = +2°C

4.31

3.35

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

5.82

4.24

Cdh Tj = +7 °C

0.974

0.981

Pdh Tj = 12°C

4.90 kW

4.80 kW

COP Tj = 12°C

7.81

5.31

Cdh Tj = +12 °C

0.969

0.979

Pdh Tj = Tbiv

8.90 kW

8.50 kW

COP Tj = Tbiv

2.88

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.80 kW

8.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.96

WTOL

60 °C

60 °C

Poff

19 W

19 W

PTO

22 W

22 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4630 kWh

5941 kWh

HPS60-12 / AHPS60-12
Configure model
Model name
HPS60-12 / AHPS60-12
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Cooling

EN 14511-2

+7°C/+12°C

El input

2.79 kW

Cooling capacity

8.51

EER

3.05

EN 14825

+7°C/+12°C

Pdesignc

8.51 kW

SEER

4.25

Pdc Tj = 35°C

8.51 kW

EER Tj = 35°C

3.05

Pdc Tj = 30°C

6.28 kW

EER Tj = 30°C

4.03

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

3.98 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

4.23 kW

EER Tj = 20°C

6.32

Cdc Tj = 20 °C

1.0

Poff

19 W

PTO

0 W

PSB

19 W

PCK

30 W

Annual energy consumption Qce

1202 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.35 kW

7.08 kW

El input

1.52 kW

2.28 kW

COP

4.84

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

135 %

Prated

10.00 kW

10.00 kW

SCOP

4.58

3.45

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.70 kW

8.40 kW

COP Tj = -7°C

2.90

2.09

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.30 kW

5.20 kW

COP Tj = +2°C

4.42

3.44

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

6.14

4.47

Cdh Tj = +7 °C

0.973

0.980

Pdh Tj = 12°C

4.80 kW

4.80 kW

COP Tj = 12°C

8.00

5.44

Cdh Tj = +12 °C

0.969

0.978

Pdh Tj = Tbiv

8.70 kW

8.40 kW

COP Tj = Tbiv

2.90

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.40 kW

8.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

19 W

19 W

PTO

22 W

22 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4453 kWh

5709 kWh

HPS60-12TR / AHPS60-12TR
Configure model
Model name
HPS60-12TR / AHPS60-12TR
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Cooling

EN 14511-2

+7°C/+12°C

El input

2.79 kW

Cooling capacity

8.51

EER

3.05

EN 14825

+7°C/+12°C

Pdesignc

8.51 kW

SEER

4.25

Pdc Tj = 35°C

8.51 kW

EER Tj = 35°C

3.05

Pdc Tj = 30°C

6.28 kW

EER Tj = 30°C

4.03

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

3.98 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

4.23 kW

EER Tj = 20°C

6.32

Cdc Tj = 20 °C

1.0

Poff

19 W

PTO

0 W

PSB

19 W

PCK

30 W

Annual energy consumption Qce

1202 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.35 kW

7.08 kW

El input

1.52 kW

2.28 kW

COP

4.84

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

135 %

Prated

10.00 kW

10.00 kW

SCOP

4.58

3.45

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.70 kW

8.40 kW

COP Tj = -7°C

2.90

2.09

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.30 kW

5.20 kW

COP Tj = +2°C

4.42

3.44

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.30 kW

4.20 kW

COP Tj = +7°C

6.14

4.47

Cdh Tj = +7 °C

0.973

0.980

Pdh Tj = 12°C

4.80 kW

4.80 kW

COP Tj = 12°C

8.00

5.44

Cdh Tj = +12 °C

0.969

0.978

Pdh Tj = Tbiv

8.70 kW

8.40 kW

COP Tj = Tbiv

2.90

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.40 kW

8.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

19 W

19 W

PTO

22 W

22 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4453 kWh

5709 kWh