Certificate holders

Subtype

TTL 4.5 ACS

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0117
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTL 4.5 ACS
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,100 kg

Certification Date
19.01.2017
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 3

Models

TTL 4.5 ACS + HSBC 200, HSBC 200 S
Configure model
Model name
TTL 4.5 ACS + HSBC 200, HSBC 200 S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.27 kW

1.92 kW

El input

0.50 kW

0.74 kW

COP

4.54

2.59

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

116 %

Prated

4.59 kW

3.83 kW

SCOP

4.20

2.96

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

4.03 kW

2.79 kW

COP Tj = -7°C

2.67

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.53 kW

2.01 kW

COP Tj = +2°C

4.00

2.94

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.63 kW

1.25 kW

COP Tj = +7°C

6.06

4.13

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.67 kW

1.54 kW

COP Tj = 12°C

6.43

5.13

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.03 kW

3.09 kW

COP Tj = Tbiv

2.67

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.80 kW

2.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.79 kW

3.83 kW

Annual energy consumption Qhe

2258 kWh

2672 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

1:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

TTL 4.5 ACS + HSBB 200 classic, HSBB 200 S classic
Configure model
Model name
TTL 4.5 ACS + HSBB 200 classic, HSBB 200 S classic
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.27 kW

1.92 kW

El input

0.50 kW

0.74 kW

COP

4.54

2.59

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

116 %

Prated

4.59 kW

3.83 kW

SCOP

4.20

2.96

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

4.03 kW

2.79 kW

COP Tj = -7°C

2.67

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.53 kW

2.01 kW

COP Tj = +2°C

4.00

2.94

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.63 kW

1.25 kW

COP Tj = +7°C

6.06

4.13

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.67 kW

1.54 kW

COP Tj = 12°C

6.43

5.13

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.03 kW

30.90 kW

COP Tj = Tbiv

2.67

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.80 kW

2.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.79 kW

3.83 kW

Annual energy consumption Qhe

2258 kWh

2672 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

1:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

TTL 4.5 ACS, low temperature, all climates
Configure model
Model name
TTL 4.5 ACS, low temperature, all climates
Application
Heating (low temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

2.27 kW

El input

0.50 kW

COP

4.54

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Sound power level indoor

52 dB(A)

Sound power level outdoor

52 dB(A)

EN 14825

ηs

165 %

Prated

4.59 kW

SCOP

4.20

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

4.03 kW

COP Tj = -7°C

2.67

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

2.53 kW

COP Tj = +2°C

4.00

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

1.63 kW

COP Tj = +7°C

6.06

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

1.67 kW

COP Tj = 12°C

6.43

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

4.03 kW

COP Tj = Tbiv

2.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.79 kW

Annual energy consumption Qhe

2258 kWh

Warmer Climate

EN 12102-1

Sound power level outdoor

52 dB(A)

EN 14825

ηs

203 %

Prated

3.48 kW

SCOP

5.14

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

3.48 kW

COP Tj = +2°C

3.23

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

2.51 kW

COP Tj = +7°C

5.18

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

1.64 kW

COP Tj = 12°C

6.23

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

3.48 kW

COP Tj = Tbiv

3.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.48 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

904 kWh

Colder Climate

EN 12102-1

Sound power level outdoor

52 dB(A)

EN 14825

ηs

147 %

Prated

4.29 kW

SCOP

3.76

Tbiv

-15 °C

TOL

-20 °C

Pdh Tj = -7°C

2.94 kW

COP Tj = -7°C

3.12

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

1.75 kW

COP Tj = +2°C

4.61

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

1.42 kW

COP Tj = +7°C

6.34

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

1.65 kW

COP Tj = 12°C

6.27

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

3.48 kW

COP Tj = Tbiv

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

4.29 kW

Annual energy consumption Qhe

2812 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.48

COP Tj = -15°C (if TOL<-20°C)

2.52

Cdh Tj = -15 °C

0.900