Certificate holders

Subtype

TTL 3.5 ACS

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0116
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTL 3.5 ACS
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,100 kg

Certification Date
19.01.2017
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 3

Models

TTL 3.5 ACS + HSBB 200 classic, HSBB 200 S classic
Configure model
Model name
TTL 3.5 ACS + HSBB 200 classic, HSBB 200 S classic
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.27 kW

1.92 kW

El input

0.50 kW

0.74 kW

COP

4.54

2.59

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

116 %

Prated

3.62 kW

3.83 kW

SCOP

4.22

2.96

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

3.20 kW

2.79 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

1.95 kW

2.01 kW

COP Tj = +2°C

4.11

2.94

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.59 kW

1.25 kW

COP Tj = +7°C

5.81

4.13

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.66 kW

1.54 kW

COP Tj = 12°C

6.34

5.13

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.20 kW

3.09 kW

COP Tj = Tbiv

2.88

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.04 kW

2.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

2.01

Rated airflow rate

0 m³/h

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.58 kW

3.83 kW

Annual energy consumption Qhe

1771 kWh

2672 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

1:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

TTL 3.5 ACS
Configure model
Model name
TTL 3.5 ACS
Application
Heating (low temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

2.27 kW

El input

0.50 kW

COP

4.54

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

0 dB(A)

Sound power level outdoor

52 dB(A)

EN 14825

ηs

200 %

Prated

3.00 kW

SCOP

5.07

Tbiv

2 °C

TOL

2 °C

Pdh Tj = -7°C

0.00 kW

COP Tj = -7°C

0.00

Pdh Tj = +2°C

3.04 kW

COP Tj = +2°C

3.39

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

1.95 kW

COP Tj = +7°C

5.18

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

1.63 kW

COP Tj = 12°C

6.14

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

3.04 kW

COP Tj = Tbiv

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.39

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

791 kWh

Colder Climate

EN 12102-1

Sound power level indoor

0 dB(A)

Sound power level outdoor

52 dB(A)

EN 14825

ηs

148 %

Prated

3.38 kW

SCOP

3.77

Tbiv

-15 °C

TOL

-20 °C

Pdh Tj = -7°C

2.05 kW

COP Tj = -7°C

3.20

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

1.25 kW

COP Tj = +2°C

4.55

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

1.39 kW

COP Tj = +7°C

6.03

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

1.64 kW

COP Tj = 12°C

6.22

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

2.76 kW

COP Tj = Tbiv

2.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.13

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

3.38 kW

Annual energy consumption Qhe

2208 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

COP Tj = -15°C (if TOL<-20°C)

 

Cdh Tj = -15 °C

 

Average Climate

EN 12102-1

Sound power level indoor

0 dB(A)

Sound power level outdoor

52 dB(A)

EN 14825

ηs

166 %

Prated

3.62 kW

SCOP

4.22

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

3.20 kW

COP Tj = -7°C

2.88

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

1.95 kW

COP Tj = +2°C

4.11

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

1.59 kW

COP Tj = +7°C

5.81

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

1.66 kW

COP Tj = 12°C

6.34

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

3.20 kW

COP Tj = Tbiv

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.07

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.58 kW

Annual energy consumption Qhe

1771 kWh

TTL 3.5 ACS + HSBC 200, HSBC 200 S
Configure model
Model name
TTL 3.5 ACS + HSBC 200, HSBC 200 S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.27 kW

1.92 kW

El input

0.50 kW

0.74 kW

COP

4.54

2.59

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

116 %

Prated

3.62 kW

3.83 kW

SCOP

4.22

2.96

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

3.20 kW

2.79 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

1.95 kW

2.01 kW

COP Tj = +2°C

4.11

2.94

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.59 kW

1.25 kW

COP Tj = +7°C

5.81

4.13

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.66 kW

1.54 kW

COP Tj = 12°C

6.34

5.13

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.20 kW

3.09 kW

COP Tj = Tbiv

2.88

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

3.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.20

Rated airflow rate

0 m³/h

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.58 kW

3.83 kW

Annual energy consumption Qhe

1771 kWh

2672 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

1:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l