Certificate holders

Subtype

M thermal P series 5 7 9 kW

Certificate Holder
GD Midea Heating & Ventilating Equipment Co., Ltd.
Penglai Industry Road
528311 Beijiao, Shunde, Foshan
China
Registration number
041-K007-14
Certification Body
BRE Global Limited
Subtype title
M thermal P series 5 7 9 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,250 kg

Certification Date
14.12.2021
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 3

Models

MHC-V5W/D2N8-C
Configure model
Model name
MHC-V5W/D2N8-C
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.5 kW

6.3 kW

El input

1.23 kW

1.97 kW

COP

5.3

3.2

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

268.2 %

170.9 %

Prated

6.24 kW

6.17 kW

SCOP

6.78

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.69 kW

6.17 kW

COP Tj = +2°C

4.31

2.77

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

4.01 kW

3.97 kW

COP Tj = +7°C

6.39

3.9

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

2.07 kW

2.06 kW

COP Tj = 12°C

8.71

5.28

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

4.01 kW

3.97 kW

COP Tj = Tbiv

6.39

3.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.69 kW

6.17 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.31

2.77

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.55 kW

0 kW

Annual energy consumption Qhe

1229 kWh

1895 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173.4 %

113.12 %

Prated

6.13 kW

5.22 kW

SCOP

4.41

2.9

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.11 kW

3.21 kW

COP Tj = -7°C

3.76

2.6

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

2.38 kW

2.03 kW

COP Tj = +2°C

5.33

3.18

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.66 kW

1.56 kW

COP Tj = +7°C

5.78

4.5

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.87 kW

1.44 kW

COP Tj = 12°C

9.12

5.83

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

5 kW

4.25 kW

COP Tj = Tbiv

3.02

2

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.21 kW

3.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.32

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.92 kW

1.98 kW

Annual energy consumption Qhe

3425 kWh

4428 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5

4.25

COP Tj = -15°C (if TOL<-20°C)

3.02

2

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201.8 %

140.72 %

Prated

6.52 kW

6.36 kW

SCOP

5.12

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.77 kW

5.62 kW

COP Tj = -7°C

3.43

2.36

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.74 kW

3.52 kW

COP Tj = +2°C

5.04

3.7

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

2.32 kW

2.2 kW

COP Tj = +7°C

6.06

4.21

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.87 kW

1.31 kW

COP Tj = 12°C

9.12

4.96

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

5.77 kW

5.62 kW

COP Tj = Tbiv

3.43

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.52 kW

6.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3

2.02

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0.32 kW

Annual energy consumption Qhe

2631 kWh

3655 kWh

MHC-V7W/D2N8-C
Configure model
Model name
MHC-V7W/D2N8-C
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

8.20 kW

El input

1.66 kW

2.60 kW

COP

5.05

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

274.74 %

185.3 %

Prated

8.06 kW

8.10 kW

SCOP

6.94

4.71

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.23 kW

7.80 kW

COP Tj = +2°C

4.04

2.68

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.18 kW

5.22 kW

COP Tj = +7°C

6.35

4.07

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.46 kW

2.36 kW

COP Tj = 12°C

9.30

6.07

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.18 kW

5.22 kW

COP Tj = Tbiv

6.35

4.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.23 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.04

2.68

WTOL

65.00 °C

65.00 °C

Poff

13.00 W

13.00 W

PTO

20.00 W

20.00 W

PSB

13.00 W

13.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.84 kW

0.32 kW

Annual energy consumption Qhe

1551 kWh

2303 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174.6 %

117.73 %

Prated

7.51 kW

6.06 kW

SCOP

4.44

3.02

Tbiv

-15.00 °C

-15.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

4.42 kW

3.95 kW

COP Tj = -7°C

3.67

2.75

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

2.99 kW

2.25 kW

COP Tj = +2°C

5.50

3.30

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.03 kW

1.56 kW

COP Tj = +7°C

6.69

4.50

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.87 kW

1.44 kW

COP Tj = 12°C

9.12

5.83

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.12 kW

4.94 kW

COP Tj = Tbiv

2.70

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.78 kW

3.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.32

WTOL

65.00 °C

65.00 °C

Poff

13.00 W

13.00 W

PTO

20.00 W

20.00 W

PSB

13.00 W

13.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.72 kW

2.82 kW

Annual energy consumption Qhe

4166 kWh

4948 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.12

4.94

COP Tj = -15°C (if TOL<-20°C)

2.70

2.08

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203.99 %

143.64 %

Prated

7.90 kW

7.25 kW

SCOP

5.17

3.67

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.99 kW

6.42 kW

COP Tj = -7°C

3.29

2.31

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.51 kW

4.03 kW

COP Tj = +2°C

4.99

3.76

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.81 kW

2.56 kW

COP Tj = +7°C

6.72

4.48

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.87 kW

1.31 kW

COP Tj = 12°C

9.12

4.96

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.99 kW

6.42 kW

COP Tj = Tbiv

3.29

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.46 kW

6.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.98

WTOL

65.00 °C

65.00 °C

Poff

13.00 W

13.00 W

PTO

20.00 W

20.00 W

PSB

13.00 W

13.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.44 kW

0.40 kW

Annual energy consumption Qhe

3155 kWh

4088 kWh

MHC-V9WD2N8-C
Configure model
Model name
MHC-V9WD2N8-C
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10 kW

9.4 kW

El input

2.13 kW

3.03 kW

COP

4.7

3.1

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

279.05 %

193.4 %

Prated

9.04 kW

9.03 kW

SCOP

7.05

4.91

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.29 kW

8.42 kW

COP Tj = +2°C

3.85

2.68

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.81 kW

5.81 kW

COP Tj = +7°C

6.24

4.16

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

2.67 kW

2.74 kW

COP Tj = 12°C

9.63

6.64

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

5.81 kW

5.81 kW

COP Tj = Tbiv

6.24

4.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.29 kW

8.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.85

2.68

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.75 kW

0.61 kW

Annual energy consumption Qhe

1714 kWh

2458 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174.6 %

122.4 %

Prated

8.27 kW

7.21 kW

SCOP

4.44

3.14

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.42 kW

4.59 kW

COP Tj = -7°C

3.72

2.72

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

5.56

3.6

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

2.16 kW

1.76 kW

COP Tj = +7°C

6.55

4.84

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.87 kW

1.44 kW

COP Tj = 12°C

9.12

5.83

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

6.75 kW

5.88 kW

COP Tj = Tbiv

2.59

2.1

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.08 kW

3.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.01

1.32

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.19 kW

3.97 kW

Annual energy consumption Qhe

4591 kWh

5665 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.75

5.88

COP Tj = -15°C (if TOL<-20°C)

2.59

2.1

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201.91 %

145.47 %

Prated

9.06 kW

8.16 kW

SCOP

5.12

3.71

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.02 kW

7.21 kW

COP Tj = -7°C

3.09

2.24

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5.06 kW

4.56 kW

COP Tj = +2°C

4.92

3.86

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.22 kW

2.84 kW

COP Tj = +7°C

7.03

4.58

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.87 kW

1.31 kW

COP Tj = 12°C

9.12

4.96

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.02 kW

7.21 kW

COP Tj = Tbiv

3.09

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.88 kW

7.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.97

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.18 kW

1.14 kW

Annual energy consumption Qhe

3654 kWh

4539 kWh