Certificate holders

Subtype

S12L-M-CC

Certificate Holder
Heliotherm GmbH
Sportplatzweg 18
A-6336 Langkampfen
Austria
Registration number
011-1W0478
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
S12L-M-CC
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

6,600 kg

Certification Date
14.12.2017
Testing basis
HP KEYMARK certification scheme rules rev. 8
Generate PDF Export model CSV
  • Number of models 1

Models

HELIOTHERM - Luft/Wasserwärmepumpe modulierend Baureihe Sensor Comfort Compact
Configure model
Model name
HELIOTHERM - Luft/Wasserwärmepumpe modulierend Baureihe Sensor Comfort Compact
Application
Heating (low temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

7.99 kW

El input

1.70 kW

COP

4.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level outdoor

50 dB(A)

EN 14825

ηs

215 %

Prated

12.00 kW

SCOP

5.45

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

11.91 kW

COP Tj = +2°C

4.30

Cdh Tj = +2 °C

0.990

Pdh Tj = +7°C

7.65 kW

COP Tj = +7°C

5.40

Cdh Tj = +7 °C

0.990

Pdh Tj = 12°C

5.42 kW

COP Tj = 12°C

5.73

Cdh Tj = +12 °C

0.990

Pdh Tj = Tbiv

11.91 kW

COP Tj = Tbiv

4.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

WTOL

62 °C

Poff

1 W

PTO

7 W

PSB

7 W

PCK

6 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.09 kW

Annual energy consumption Qhe

3083 kWh

Colder Climate

EN 12102-1

Sound power level outdoor

50 dB(A)

EN 14825

ηs

149 %

Prated

12.00 kW

SCOP

4.14

Tbiv

-19 °C

TOL

-22 °C

Pdh Tj = -7°C

7.17 kW

COP Tj = -7°C

3.45

Cdh Tj = -7 °C

0.990

Pdh Tj = +2°C

4.59 kW

COP Tj = +2°C

4.48

Cdh Tj = +2 °C

0.990

Pdh Tj = +7°C

4.61 kW

COP Tj = +7°C

4.85

Cdh Tj = +7 °C

0.990

Pdh Tj = 12°C

5.43 kW

COP Tj = 12°C

5.69

Cdh Tj = +12 °C

0.990

Pdh Tj = Tbiv

11.22 kW

COP Tj = Tbiv

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.61

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

WTOL

62 °C

Poff

1 W

PTO

7 W

PSB

7 W

PCK

6 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

2.60 kW

Annual energy consumption Qhe

6087 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.47

COP Tj = -15°C (if TOL<-20°C)

2.40

Cdh Tj = -15 °C

0.990

Average Climate

EN 12102-1

Sound power level outdoor

50 dB(A)

EN 14825

ηs

180 %

Prated

12.00 kW

SCOP

4.57

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

10.62 kW

COP Tj = -7°C

2.72

Cdh Tj = -7 °C

0.997

Pdh Tj = +2°C

6.57 kW

COP Tj = +2°C

4.69

Cdh Tj = +2 °C

0.993

Pdh Tj = +7°C

7.48 kW

COP Tj = +7°C

5.64

Cdh Tj = +7 °C

0.987

Pdh Tj = 12°C

8.35 kW

COP Tj = 12°C

6.91

Cdh Tj = +12 °C

0.982

Pdh Tj = Tbiv

11.99 kW

COP Tj = Tbiv

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.998

WTOL

62 °C

Poff

1 W

PTO

7 W

PSB

7 W

PCK

6 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.01 kW

Annual energy consumption Qhe

5450 kWh