4,400 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
20.77 kW
19.87 kW
El input
4.56 kW
6.48 kW
COP
4.55
3.07
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
165 %
Prated
28.00 kW
28.00 kW
SCOP
5.47
4.32
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
17.00 kW
17.00 kW
COP Tj = -7°C
5.10
3.90
Pdh Tj = +2°C
10.30 kW
10.30 kW
COP Tj = +2°C
5.50
4.50
Pdh Tj = +7°C
6.60 kW
6.60 kW
COP Tj = +7°C
6.30
5.40
Pdh Tj = 12°C
3.80 kW
3.70 kW
COP Tj = 12°C
5.90
5.40
Pdh Tj = Tbiv
28.00 kW
28.00 kW
COP Tj = Tbiv
4.10
2.80
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
28.00 kW
28.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.10
2.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.97
0.98
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
50 W
35 W
PSB
19 W
19 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
12907 kWh
16450 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
155 %
Prated
28.00 kW
28.00 kW
SCOP
5.07
4.07
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
24.80 kW
25.00 kW
COP Tj = -7°C
4.40
3.10
Pdh Tj = +2°C
15.60 kW
15.30 kW
COP Tj = +2°C
4.90
3.90
Pdh Tj = +7°C
9.70 kW
9.70 kW
COP Tj = +7°C
5.60
4.60
Pdh Tj = 12°C
4.30 kW
4.30 kW
COP Tj = 12°C
6.10
5.30
Pdh Tj = Tbiv
28.00 kW
28.00 kW
COP Tj = Tbiv
4.10
2.80
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
28.00 kW
28.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.10
2.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
50 W
35 W
PSB
19 W
19 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
11528 kWh
14621 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
26.68 kW
25.23 kW
El input
4.76 kW
6.37 kW
COP
5.60
3.96
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
197 %
Prated
35.00 kW
35.00 kW
SCOP
6.37
4.99
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
21.20 kW
21.20 kW
COP Tj = -7°C
6.20
4.60
Pdh Tj = +2°C
12.90 kW
12.90 kW
COP Tj = +2°C
6.50
5.30
Pdh Tj = +7°C
8.30 kW
8.30 kW
COP Tj = +7°C
7.50
6.40
Pdh Tj = 12°C
6.90 kW
6.80 kW
COP Tj = 12°C
7.40
6.60
Pdh Tj = Tbiv
35.00 kW
35.00 kW
COP Tj = Tbiv
4.90
3.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.00 kW
35.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.90
3.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.97
0.98
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
65 W
45 W
PSB
19 W
19 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
13541 kWh
17279 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
243 %
188 %
Prated
35.00 kW
35.00 kW
SCOP
6.15
4.79
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
31.00 kW
31.00 kW
COP Tj = -7°C
5.40
3.80
Pdh Tj = +2°C
21.60 kW
18.80 kW
COP Tj = +2°C
6.10
4.70
Pdh Tj = +7°C
12.10 kW
12.10 kW
COP Tj = +7°C
6.60
5.50
Pdh Tj = 12°C
7.00 kW
6.80 kW
COP Tj = 12°C
7.70
6.60
Pdh Tj = Tbiv
35.00 kW
35.00 kW
COP Tj = Tbiv
4.90
3.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.00 kW
35.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.90
3.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.97
0.99
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
65 W
45 W
PSB
19 W
19 W
PCK
25 W
25 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
11765 kWh
15111 kWh