2,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
12.00 kW
El input
2.53 kW
4.10 kW
COP
4.74
2.93
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
134 %
Prated
10.00 kW
8.00 kW
SCOP
4.82
3.42
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.90 kW
7.20 kW
COP Tj = -7°C
3.18
2.27
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.20 kW
4.30 kW
COP Tj = +2°C
4.67
3.25
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.20 kW
4.90 kW
COP Tj = +7°C
6.15
4.36
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.10 kW
5.80 kW
COP Tj = 12°C
7.88
6.12
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
10.00 kW
8.00 kW
COP Tj = Tbiv
2.68
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.00 kW
8.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
39 W
39 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4286 kWh
4840 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
14.50 kW
El input
3.74 kW
5.33 kW
COP
4.28
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
128 %
Prated
12.00 kW
13.00 kW
SCOP
4.82
3.25
Tbiv
-10 °C
-3 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.10 kW
9.00 kW
COP Tj = -7°C
2.90
2.07
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.40 kW
7.10 kW
COP Tj = +2°C
4.83
3.29
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.11
4.85
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
6.20 kW
5.80 kW
COP Tj = 12°C
7.59
4.85
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.80 kW
9.50 kW
COP Tj = Tbiv
2.77
2.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
8.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
55 °C
55 °C
Poff
3 W
3 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
39 W
39 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
4.30 kW
Annual energy consumption Qhe
5146 kWh
8076 kWh