Certificate holders

Subtype

Aquarea Split 16 kW T-CAP (H Series)

Certificate Holder
Panasonic Marketing Europe GmbH
Hagenauer Strasse 43, Wiesbaden
65203 Wiesbaden
Germany
Registration number
011-1W0510
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquarea Split 16 kW T-CAP (H Series)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,900 kg

Certification Date
08.12.2021
Testing basis
HP KEYMARK certification scheme rules rev. 9
Generate PDF Export model CSV
  • Number of models 6

Models

WH-ADC0916H9E8 / WH-UX16HE8
Configure model
Model name
WH-ADC0916H9E8 / WH-UX16HE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.74 kW

5.91 kW

COP

4.28

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

125 %

Prated

16.00 kW

16.00 kW

SCOP

4.08

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.30 kW

COP Tj = -7°C

2.70

2.07

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.30 kW

8.20 kW

COP Tj = +2°C

3.65

2.93

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.80 kW

7.20 kW

COP Tj = +7°C

5.96

4.44

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.90 kW

8.50 kW

COP Tj = 12°C

6.88

5.86

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.90 kW

15.80 kW

COP Tj = Tbiv

2.63

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

15.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

3 W

3 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.20 kW

Annual energy consumption Qhe

8107 kWh

10330 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.27

Heating up time

0:44 h:min

Standby power input

41.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

253 l

WH-ADC0916H9E8AN / WH-UX16HE8
Configure model
Model name
WH-ADC0916H9E8AN / WH-UX16HE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.74 kW

5.91 kW

COP

4.28

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

125 %

Prated

16.00 kW

16.00 kW

SCOP

4.08

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.30 kW

COP Tj = -7°C

2.70

2.07

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.30 kW

8.20 kW

COP Tj = +2°C

3.65

2.93

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.80 kW

7.20 kW

COP Tj = +7°C

5.96

4.44

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.90 kW

8.50 kW

COP Tj = 12°C

6.88

5.86

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.90 kW

15.80 kW

COP Tj = Tbiv

2.63

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

15.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

3 W

3 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.20 kW

Annual energy consumption Qhe

8107 kWh

10330 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.27

Heating up time

0:44 h:min

Standby power input

41.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

253 l

WH-ADC0916H9E8 / WH-UQ16HE8
Configure model
Model name
WH-ADC0916H9E8 / WH-UQ16HE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.74 kW

5.91 kW

COP

4.28

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

125 %

Prated

16.00 kW

16.00 kW

SCOP

4.08

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.30 kW

COP Tj = -7°C

2.70

2.07

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.30 kW

8.20 kW

COP Tj = +2°C

3.65

2.93

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.80 kW

7.20 kW

COP Tj = +7°C

5.96

4.44

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.90 kW

8.50 kW

COP Tj = 12°C

6.88

5.86

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.90 kW

15.80 kW

COP Tj = Tbiv

2.63

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

15.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

3 W

3 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.20 kW

Annual energy consumption Qhe

8107 kWh

10330 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.27

Heating up time

0:44 h:min

Standby power input

41.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

253 l

WH-ADC0916H9E8AN / WH-UQ16HE8
Configure model
Model name
WH-ADC0916H9E8AN / WH-UQ16HE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.74 kW

5.91 kW

COP

4.28

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

125 %

Prated

16.00 kW

16.00 kW

SCOP

4.08

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.30 kW

COP Tj = -7°C

2.70

2.07

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.30 kW

8.20 kW

COP Tj = +2°C

3.65

2.93

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.80 kW

7.20 kW

COP Tj = +7°C

5.96

4.44

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.90 kW

8.50 kW

COP Tj = 12°C

6.88

5.86

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.90 kW

15.80 kW

COP Tj = Tbiv

2.63

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

15.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

3 W

3 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.20 kW

Annual energy consumption Qhe

8107 kWh

10330 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.27

Heating up time

0:44 h:min

Standby power input

41.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

253 l

WH-SXC16H9E8 / WH-UX16HE8
Configure model
Model name
WH-SXC16H9E8 / WH-UX16HE8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.74 kW

5.91 kW

COP

4.28

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

125 %

Prated

16.00 kW

16.00 kW

SCOP

4.08

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.30 kW

COP Tj = -7°C

2.70

2.07

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.30 kW

8.20 kW

COP Tj = +2°C

3.65

2.93

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.80 kW

7.20 kW

COP Tj = +7°C

5.96

4.44

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.90 kW

8.50 kW

COP Tj = 12°C

6.88

5.86

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.90 kW

15.80 kW

COP Tj = Tbiv

2.63

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

15.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

3 W

3 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.20 kW

Annual energy consumption Qhe

8107 kWh

10330 kWh

WH-SQC16H9E8 / WH-UQ16HE8
Configure model
Model name
WH-SQC16H9E8 / WH-UQ16HE8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.74 kW

5.91 kW

COP

4.28

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

125 %

Prated

16.00 kW

16.00 kW

SCOP

4.08

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.30 kW

COP Tj = -7°C

2.70

2.07

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.30 kW

8.20 kW

COP Tj = +2°C

3.65

2.93

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

7.80 kW

7.20 kW

COP Tj = +7°C

5.96

4.44

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.90 kW

8.50 kW

COP Tj = 12°C

6.88

5.86

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.90 kW

15.80 kW

COP Tj = Tbiv

2.63

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.90 kW

15.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

3 W

3 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.20 kW

Annual energy consumption Qhe

8107 kWh

10330 kWh