Certificate holders

Subtype

36. Yutaki S (N1) 8.0HP R410A (3ph)

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-57
Certification Body
BRE Global Limited
Subtype title
36. Yutaki S (N1) 8.0HP R410A (3ph)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

5,000 kg

Certification Date
08.02.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

01. RAS-8WHNPE RWM-8.0N1E - Heating Only
Configure model
Model name
01. RAS-8WHNPE RWM-8.0N1E - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.00 kW

20.00 kW

El input

4.65 kW

7.35 kW

COP

4.30

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

120 %

Prated

18.00 kW

16.00 kW

SCOP

3.83

3.08

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

15.60 kW

13.80 kW

COP Tj = -7°C

2.50

1.65

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.50 kW

8.40 kW

COP Tj = +2°C

3.85

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.10 kW

6.00 kW

COP Tj = +7°C

5.40

4.76

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.00 kW

6.80 kW

COP Tj = 12°C

4.65

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

15.60 kW

13.80 kW

COP Tj = Tbiv

2.50

1.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

36 W

36 W

PTO

0 W

0 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

3.90 kW

Annual energy consumption Qhe

9513 kWh

10452 kWh

02. RAS-8WHNPE RWM-8.0N1E - with cooling kit
Configure model
Model name
02. RAS-8WHNPE RWM-8.0N1E - with cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.00 kW

20.00 kW

El input

4.65 kW

7.35 kW

COP

4.30

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.48 kW

4.46 kW

Cooling capacity

14.00

17.00

EER

3.12

3.81

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

14.00 kW

17.00 kW

SEER

4.29

5.40

Pdc Tj = 35°C

14.00 kW

17.00 kW

EER Tj = 35°C

3.12

3.81

Pdc Tj = 30°C

10.32 kW

12.53 kW

EER Tj = 30°C

3.92

5.60

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.50 kW

8.20 kW

EER Tj = 25°C

5.30

6.50

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

8.00 kW

8.50 kW

EER Tj = 20°C

5.80

6.60

Cdc Tj = 20 °C

0.900

0.900

Poff

36 W

36 W

PTO

0 W

0 W

PSB

36 W

36 W

PCK

0 W

0 W

Annual energy consumption Qce

1142 kWh

1102 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

122 %

Prated

18.00 kW

16.00 kW

SCOP

3.83

3.08

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

15.60 kW

13.80 kW

COP Tj = -7°C

2.50

1.65

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.50 kW

8.40 kW

COP Tj = +2°C

3.85

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.10 kW

6.00 kW

COP Tj = +7°C

5.40

4.76

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.00 kW

6.80 kW

COP Tj = 12°C

4.65

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

15.60 kW

13.80 kW

COP Tj = Tbiv

2.50

1.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

36 W

36 W

PTO

0 W

0 W

PSB

36 W

36 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

3.90 kW

Annual energy consumption Qhe

9382 kWh

10320 kWh