Certificate holders

Subtype

NIMBUS/ARIANEXT/AEROTOP/ENERGION 35/50 S - COMPACT

Certificate Holder
Ariston Thermo Group
Viale Aristide Merloni 45
I-60044 Fabriano (AN)
Italy
Registration number
ICIM-PDC-000112 / 02
Certification Body
ICIM S.p.A.
Subtype title
NIMBUS/ARIANEXT/AEROTOP/ENERGION 35/50 S - COMPACT
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,400 kg

Certification Date
05.07.2022
Testing basis
Heat Pump KEYMARK rev9
Generate PDF Export model CSV Download certificate
  • Number of models 18

Models

NIMBUS COMPACT 35 S NET R32
Configure model
Model name
NIMBUS COMPACT 35 S NET R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:55 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

NIMBUS COMPACT 50 S NET R32
Configure model
Model name
NIMBUS COMPACT 50 S NET R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:31 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

NIMBUS COMPACT 35 S 2Z NET R32
Configure model
Model name
NIMBUS COMPACT 35 S 2Z NET R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:55 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

NIMBUS COMPACT 50 S 2Z NET R32
Configure model
Model name
NIMBUS COMPACT 50 S 2Z NET R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:31 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

ARIANEXT COMPACT 35 S 2Z LINK R32
Configure model
Model name
ARIANEXT COMPACT 35 S 2Z LINK R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:55 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

ARIANEXT COMPACT 35 S LINK R32
Configure model
Model name
ARIANEXT COMPACT 35 S LINK R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:55 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

ARIANEXT COMPACT 50 S 2Z LINK R32
Configure model
Model name
ARIANEXT COMPACT 50 S 2Z LINK R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:31 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

ARIANEXT COMPACT 50 S LINK R32
Configure model
Model name
ARIANEXT COMPACT 50 S LINK R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:31 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

AEROTOP SPLIT 04.2 M-CRX 2Z
Configure model
Model name
AEROTOP SPLIT 04.2 M-CRX 2Z
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:55 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

AEROTOP SPLIT 04.2 M-CRX 1Z
Configure model
Model name
AEROTOP SPLIT 04.2 M-CRX 1Z
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:55 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

AEROTOP SPLIT 05.2 M-CRX 2Z
Configure model
Model name
AEROTOP SPLIT 05.2 M-CRX 2Z
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:31 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

AEROTOP SPLIT 05.2 M-CRX 1Z
Configure model
Model name
AEROTOP SPLIT 05.2 M-CRX 1Z
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:31 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

NIMBUS FLEX 35 S NET R32
Configure model
Model name
NIMBUS FLEX 35 S NET R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

141 %

COP

3.30

Heating up time

01:52 h:min

Standby power input

32.0 W

Reference hot water temperature

53 °C

Mixed water at 40°C

244 l

NIMBUS FLEX 50 S NET R32
Configure model
Model name
NIMBUS FLEX 50 S NET R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

141 %

COP

3.30

Heating up time

01:30 h:min

Standby power input

32.0 W

Reference hot water temperature

53 °C

Mixed water at 40°C

244 l

ARIANEXT FLEX 35 S LINK R32
Configure model
Model name
ARIANEXT FLEX 35 S LINK R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

141 %

COP

3.30

Heating up time

01:52 h:min

Standby power input

32.0 W

Reference hot water temperature

53 °C

Mixed water at 40°C

244 l

ARIANEXT FLEX 50 S LINK R32
Configure model
Model name
ARIANEXT FLEX 50 S LINK R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

141 %

COP

3.30

Heating up time

01:30 h:min

Standby power input

32.0 W

Reference hot water temperature

53 °C

Mixed water at 40°C

244 l

AEROTOP SPLIT 04.2 M-C2RX
Configure model
Model name
AEROTOP SPLIT 04.2 M-C2RX
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.5

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

192 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.89

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.979

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.954

0.969

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.942

0.956

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.17 kW

2.17 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2198 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:55 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l

AEROTOP SPLIT 05.2 M-C2RX
Configure model
Model name
AEROTOP SPLIT 05.2 M-C2RX
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

3.80 kW

El input

1.00 kW

1.36 kW

COP

5.00

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.75 kW

Cooling capacity

5

EER

2.85

4.56

EN 14825

+7°C/+12°C

Pdesignc

5 kW

SEER

4.85

Pdc Tj = 35°C

5 kW

EER Tj = 35°C

2.85

Pdc Tj = 30°C

3.77 kW

EER Tj = 30°C

4.25

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

2.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

1.87 kW

EER Tj = 20°C

7.85

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

925 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.65 kW

5.65 kW

ηs

183 %

136 %

Prated

5.65 kW

5.65 kW

SCOP

4.66

3.48

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

3.10

2.28

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

3.11 kW

3.11 kW

COP Tj = +2°C

4.32

3.30

Cdh Tj = +2 °C

0.981

0.986

Pdh Tj = +7°C

1.96 kW

2.19 kW

COP Tj = +7°C

6.48

4.58

Cdh Tj = +7 °C

0.955

0.972

Pdh Tj = 12°C

1.86 kW

1.84 kW

COP Tj = 12°C

8.41

6.33

Cdh Tj = +12 °C

0.939

0.953

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.10

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.69 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.47 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2505 kWh

3360 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:31 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

233 l