Certificate holders

Subtype

27. Yutaki S (R1) & S Combi (RW1) 220L 2HP R32

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-48
Certification Body
BRE Global Limited
Subtype title
27. Yutaki S (R1) & S Combi (RW1) 220L 2HP R32
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,200 kg

Certification Date
08.02.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 6

Models

03. RAS-2WHVRP1 RWD-2.0RW1E-220S - Heating Only
Configure model
Model name
03. RAS-2WHVRP1 RWD-2.0RW1E-220S - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

4.30 kW

El input

0.82 kW

1.43 kW

COP

5.25

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

130 %

Prated

4.00 kW

4.00 kW

SCOP

4.57

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.50 kW

COP Tj = -7°C

3.20

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.35 kW

2.16 kW

COP Tj = +2°C

4.43

3.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.00 kW

2.43 kW

COP Tj = +7°C

7.41

5.20

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.05 kW

2.80 kW

COP Tj = 12°C

9.24

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.50 kW

COP Tj = Tbiv

3.20

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

1811 kWh

2463 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.20

Heating up time

1:55 h:min

Standby power input

30.0 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

288 l

04. RAS-2WHVRP1 RWD-2.0RW1E-220S - with cooling kit
Configure model
Model name
04. RAS-2WHVRP1 RWD-2.0RW1E-220S - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

4.30 kW

El input

0.82 kW

1.43 kW

COP

5.25

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.00 kW

1.02 kW

Cooling capacity

4.00

5.50

EER

4.00

5.40

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

5.50 kW

SEER

5.57

8.04

Pdc Tj = 35°C

4.00 kW

5.50 kW

EER Tj = 35°C

4.00

5.40

Pdc Tj = 30°C

2.95 kW

4.05 kW

EER Tj = 30°C

5.00

7.20

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

2.05 kW

2.61 kW

EER Tj = 25°C

6.45

9.60

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

2.88 kW

2.51 kW

EER Tj = 20°C

8.00

10.30

Cdc Tj = 20 °C

 

 

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Annual energy consumption Qce

431 kWh

410 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

132 %

Prated

4.00 kW

4.00 kW

SCOP

4.68

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.50 kW

COP Tj = -7°C

3.20

2.00

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.35 kW

2.16 kW

COP Tj = +2°C

4.43

3.25

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.00 kW

2.43 kW

COP Tj = +7°C

7.41

5.20

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.05 kW

2.80 kW

COP Tj = 12°C

9.24

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.50 kW

COP Tj = Tbiv

3.20

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

1767 kWh

2420 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.20

Heating up time

1:55 h:min

Standby power input

30.0 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

288 l

05. RAS-2WHVRP1 RWD-2.0RW1E-220S-K - UK Version - Heating Only
Configure model
Model name
05. RAS-2WHVRP1 RWD-2.0RW1E-220S-K - UK Version - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

4.30 kW

El input

0.82 kW

1.43 kW

COP

5.25

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

130 %

Prated

4.00 kW

4.00 kW

SCOP

4.57

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.50 kW

COP Tj = -7°C

3.20

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.35 kW

2.16 kW

COP Tj = +2°C

4.43

3.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.00 kW

2.43 kW

COP Tj = +7°C

7.41

5.20

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.05 kW

2.80 kW

COP Tj = 12°C

9.24

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.50 kW

COP Tj = Tbiv

3.20

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

1811 kWh

2463 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.20

Heating up time

1:55 h:min

Standby power input

30.0 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

288 l

06. RAS-2WHVRP1 RWD-2.0RW1E-220S-K - UK Version - with cooling kit
Configure model
Model name
06. RAS-2WHVRP1 RWD-2.0RW1E-220S-K - UK Version - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

4.30 kW

El input

0.82 kW

1.43 kW

COP

5.25

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.00 kW

1.02 kW

Cooling capacity

4.00

5.50

EER

4.00

5.40

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

5.50 kW

SEER

5.57

8.04

Pdc Tj = 35°C

4.00 kW

5.50 kW

EER Tj = 35°C

4.00

5.40

Pdc Tj = 30°C

2.95 kW

4.05 kW

EER Tj = 30°C

5.00

7.20

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

2.05 kW

2.61 kW

EER Tj = 25°C

6.45

9.60

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

2.88 kW

2.51 kW

EER Tj = 20°C

8.00

10.30

Cdc Tj = 20 °C

 

 

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Annual energy consumption Qce

431 kWh

410 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

132 %

Prated

4.00 kW

4.00 kW

SCOP

4.68

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.50 kW

COP Tj = -7°C

3.20

2.00

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.35 kW

2.16 kW

COP Tj = +2°C

4.43

3.25

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.00 kW

2.43 kW

COP Tj = +7°C

7.41

5.20

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.05 kW

2.80 kW

COP Tj = 12°C

9.24

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.50 kW

COP Tj = Tbiv

3.20

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

1767 kWh

2420 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.20

Heating up time

1:55 h:min

Standby power input

30.0 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

288 l

01. RAS-2WHVRP1 RWM-2.0R1E - Heating Only
Configure model
Model name
01. RAS-2WHVRP1 RWM-2.0R1E - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

4.30 kW

El input

0.82 kW

1.43 kW

COP

5.25

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

130 %

Prated

4.00 kW

4.00 kW

SCOP

4.57

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.50 kW

COP Tj = -7°C

3.20

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.35 kW

2.16 kW

COP Tj = +2°C

4.43

3.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.00 kW

2.43 kW

COP Tj = +7°C

7.41

5.20

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.05 kW

2.80 kW

COP Tj = 12°C

9.24

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.50 kW

COP Tj = Tbiv

3.20

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

1811 kWh

2463 kWh

02. RAS-2WHVRP1 RWM-2.0R1E - with cooling kit
Configure model
Model name
02. RAS-2WHVRP1 RWM-2.0R1E - with cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

4.30 kW

El input

0.82 kW

1.43 kW

COP

5.25

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.00 kW

1.02 kW

Cooling capacity

4.00

5.50

EER

4.00

5.40

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

5.50 kW

SEER

5.57

8.04

Pdc Tj = 35°C

4.00 kW

5.50 kW

EER Tj = 35°C

4.00

5.40

Pdc Tj = 30°C

2.95 kW

4.05 kW

EER Tj = 30°C

5.00

7.20

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

2.05 kW

2.61 kW

EER Tj = 25°C

6.45

9.60

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

2.88 kW

2.51 kW

EER Tj = 20°C

8.00

10.30

Cdc Tj = 20 °C

 

 

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Annual energy consumption Qce

431 kWh

410 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

49 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

132 %

Prated

4.00 kW

4.00 kW

SCOP

4.68

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.50 kW

COP Tj = -7°C

3.20

2.00

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.35 kW

2.16 kW

COP Tj = +2°C

4.43

3.25

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.00 kW

2.43 kW

COP Tj = +7°C

7.41

5.20

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.05 kW

2.80 kW

COP Tj = 12°C

9.24

6.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.50 kW

COP Tj = Tbiv

3.20

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

0 W

0 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

1767 kWh

2420 kWh