1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
5.80 kW
El input
1.67 kW
1.97 kW
COP
4.80
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.26 kW
1.49 kW
Cooling capacity
7
7.00
EER
3.10
4.70
EN 14825
+7°C/+12°C
Pdesignc
7 kW
SEER
4.64
Pdc Tj = 35°C
7 kW
EER Tj = 35°C
3.1
Pdc Tj = 30°C
5.17 kW
EER Tj = 30°C
4.13
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
3.32 kW
EER Tj = 25°C
4.89
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
3.19 kW
EER Tj = 20°C
6.85
Cdc Tj = 20 °C
0.97
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
1381 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
4.93 kW
4.48 kW
ηs
242 %
151 %
Prated
4.93 kW
4.48 kW
SCOP
6.14
3.84
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
4.93 kW
4.48 kW
COP Tj = +2°C
4.05
2.53
Cdh Tj = +2 °C
0.989
0.992
Pdh Tj = +7°C
3.10 kW
2.81 kW
COP Tj = +7°C
5.70
3.08
Cdh Tj = +7 °C
0.975
0.985
Pdh Tj = 12°C
3.28 kW
3.16 kW
COP Tj = 12°C
7.86
5.45
Cdh Tj = +12 °C
0.967
0.977
Pdh Tj = Tbiv
4.93 kW
4.48 kW
COP Tj = Tbiv
4.05
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
1073 kWh
1557 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
11.78 kW
11.53 kW
ηs
154 %
120 %
Prated
11.78 kW
11.53 kW
SCOP
3.93
3.08
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.13 kW
6.98 kW
COP Tj = -7°C
3.47
2.73
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.51 kW
4.20 kW
COP Tj = +2°C
5.32
4.07
Cdh Tj = +2 °C
0.984
0.987
Pdh Tj = +7°C
3.06 kW
2.84 kW
COP Tj = +7°C
7.24
5.15
Cdh Tj = +7 °C
0.968
0.975
Pdh Tj = 12°C
3.18 kW
3.24 kW
COP Tj = 12°C
8.02
6.47
Cdh Tj = +12 °C
0.966
0.973
Pdh Tj = Tbiv
7.13 kW
6.98 kW
COP Tj = Tbiv
3.47
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11.16 kW
10.93 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
7398 kWh
9226 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
8.37 kW
7.62 kW
ηs
195 %
140 %
Prated
8.37 kW
7.62 kW
SCOP
4.95
3.57
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.40 kW
6.74 kW
COP Tj = -7°C
3.10
2.29
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
4.54 kW
4.22 kW
COP Tj = +2°C
4.80
3.51
Cdh Tj = +2 °C
0.986
0.989
Pdh Tj = +7°C
2.94 kW
2.74 kW
COP Tj = +7°C
6.61
4.36
Cdh Tj = +7 °C
0.969
0.978
Pdh Tj = 12°C
3.16 kW
3.28 kW
COP Tj = 12°C
8.15
6.50
Cdh Tj = +12 °C
0.965
0.973
Pdh Tj = Tbiv
7.40 kW
6.74 kW
COP Tj = Tbiv
3.10
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.86 kW
2.72 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
3490 kWh
4405 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
5.80 kW
El input
1.67 kW
1.97 kW
COP
4.80
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.26 kW
1.49 kW
Cooling capacity
7
7.00
EER
3.10
4.70
EN 14825
+7°C/+12°C
Pdesignc
7 kW
SEER
4.64
Pdc Tj = 35°C
7 kW
EER Tj = 35°C
3.1
Pdc Tj = 30°C
5.17 kW
EER Tj = 30°C
4.13
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
3.32 kW
EER Tj = 25°C
4.89
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
3.19 kW
EER Tj = 20°C
6.85
Cdc Tj = 20 °C
0.97
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
1381 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
4.93 kW
4.48 kW
ηs
242 %
151 %
Prated
4.93 kW
4.48 kW
SCOP
6.14
3.84
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
4.93 kW
4.48 kW
COP Tj = +2°C
4.05
2.53
Cdh Tj = +2 °C
0.989
0.992
Pdh Tj = +7°C
3.10 kW
2.81 kW
COP Tj = +7°C
5.70
3.08
Cdh Tj = +7 °C
0.975
0.985
Pdh Tj = 12°C
3.28 kW
3.16 kW
COP Tj = 12°C
7.86
5.45
Cdh Tj = +12 °C
0.967
0.977
Pdh Tj = Tbiv
4.93 kW
4.48 kW
COP Tj = Tbiv
4.05
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
1073 kWh
1557 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
11.78 kW
11.53 kW
ηs
154 %
120 %
Prated
11.78 kW
11.53 kW
SCOP
3.93
3.08
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.13 kW
6.98 kW
COP Tj = -7°C
3.47
2.73
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.51 kW
4.20 kW
COP Tj = +2°C
5.32
4.07
Cdh Tj = +2 °C
0.984
0.987
Pdh Tj = +7°C
3.06 kW
2.84 kW
COP Tj = +7°C
7.24
5.15
Cdh Tj = +7 °C
0.968
0.975
Pdh Tj = 12°C
3.18 kW
3.24 kW
COP Tj = 12°C
8.02
6.47
Cdh Tj = +12 °C
0.966
0.973
Pdh Tj = Tbiv
7.13 kW
6.98 kW
COP Tj = Tbiv
3.47
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11.16 kW
10.93 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
7398 kWh
9226 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
8.37 kW
7.62 kW
ηs
195 %
140 %
Prated
8.37 kW
7.62 kW
SCOP
4.95
3.57
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.40 kW
6.74 kW
COP Tj = -7°C
3.10
2.29
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
4.54 kW
4.22 kW
COP Tj = +2°C
4.80
3.51
Cdh Tj = +2 °C
0.986
0.989
Pdh Tj = +7°C
2.94 kW
2.74 kW
COP Tj = +7°C
6.61
4.36
Cdh Tj = +7 °C
0.969
0.978
Pdh Tj = 12°C
3.16 kW
3.28 kW
COP Tj = 12°C
8.15
6.50
Cdh Tj = +12 °C
0.965
0.973
Pdh Tj = Tbiv
7.40 kW
6.74 kW
COP Tj = Tbiv
3.10
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.86 kW
2.72 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
3490 kWh
4405 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
5.80 kW
El input
1.67 kW
1.97 kW
COP
4.80
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.26 kW
1.49 kW
Cooling capacity
7
7.00
EER
3.10
4.70
EN 14825
+7°C/+12°C
Pdesignc
7 kW
SEER
4.64
Pdc Tj = 35°C
7 kW
EER Tj = 35°C
3.1
Pdc Tj = 30°C
5.17 kW
EER Tj = 30°C
4.13
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
3.32 kW
EER Tj = 25°C
4.89
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
3.19 kW
EER Tj = 20°C
6.85
Cdc Tj = 20 °C
0.97
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
1381 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
4.93 kW
4.48 kW
ηs
242 %
151 %
Prated
4.93 kW
4.48 kW
SCOP
6.14
3.84
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
4.93 kW
4.48 kW
COP Tj = +2°C
4.05
2.53
Cdh Tj = +2 °C
0.989
0.992
Pdh Tj = +7°C
3.10 kW
2.81 kW
COP Tj = +7°C
5.70
3.08
Cdh Tj = +7 °C
0.975
0.985
Pdh Tj = 12°C
3.28 kW
3.16 kW
COP Tj = 12°C
7.86
5.45
Cdh Tj = +12 °C
0.967
0.977
Pdh Tj = Tbiv
4.93 kW
4.48 kW
COP Tj = Tbiv
4.05
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
1073 kWh
1557 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
11.78 kW
11.53 kW
ηs
154 %
120 %
Prated
11.78 kW
11.53 kW
SCOP
3.93
3.08
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.13 kW
6.98 kW
COP Tj = -7°C
3.47
2.73
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.51 kW
4.20 kW
COP Tj = +2°C
5.32
4.07
Cdh Tj = +2 °C
0.984
0.987
Pdh Tj = +7°C
3.06 kW
2.84 kW
COP Tj = +7°C
7.24
5.15
Cdh Tj = +7 °C
0.968
0.975
Pdh Tj = 12°C
3.18 kW
3.24 kW
COP Tj = 12°C
8.02
6.47
Cdh Tj = +12 °C
0.966
0.973
Pdh Tj = Tbiv
7.13 kW
6.98 kW
COP Tj = Tbiv
3.47
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11.16 kW
10.93 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
7398 kWh
9226 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
8.37 kW
7.62 kW
ηs
195 %
140 %
Prated
8.37 kW
7.62 kW
SCOP
4.95
3.57
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.40 kW
6.74 kW
COP Tj = -7°C
3.10
2.29
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
4.54 kW
4.22 kW
COP Tj = +2°C
4.80
3.51
Cdh Tj = +2 °C
0.986
0.989
Pdh Tj = +7°C
2.94 kW
2.74 kW
COP Tj = +7°C
6.61
4.36
Cdh Tj = +7 °C
0.969
0.978
Pdh Tj = 12°C
3.16 kW
3.28 kW
COP Tj = 12°C
8.15
6.50
Cdh Tj = +12 °C
0.965
0.973
Pdh Tj = Tbiv
7.40 kW
6.74 kW
COP Tj = Tbiv
3.10
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.86 kW
2.72 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
3490 kWh
4405 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
5.80 kW
El input
1.67 kW
1.97 kW
COP
4.80
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.26 kW
1.49 kW
Cooling capacity
7
7.00
EER
3.10
4.70
EN 14825
+7°C/+12°C
Pdesignc
7 kW
SEER
4.64
Pdc Tj = 35°C
7 kW
EER Tj = 35°C
3.1
Pdc Tj = 30°C
5.17 kW
EER Tj = 30°C
4.13
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
3.32 kW
EER Tj = 25°C
4.89
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
3.19 kW
EER Tj = 20°C
6.85
Cdc Tj = 20 °C
0.97
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
1381 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
4.93 kW
4.48 kW
ηs
242 %
151 %
Prated
4.93 kW
4.48 kW
SCOP
6.14
3.84
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
4.93 kW
4.48 kW
COP Tj = +2°C
4.05
2.53
Cdh Tj = +2 °C
0.989
0.992
Pdh Tj = +7°C
3.10 kW
2.81 kW
COP Tj = +7°C
5.70
3.08
Cdh Tj = +7 °C
0.975
0.985
Pdh Tj = 12°C
3.28 kW
3.16 kW
COP Tj = 12°C
7.86
5.45
Cdh Tj = +12 °C
0.967
0.977
Pdh Tj = Tbiv
4.93 kW
4.48 kW
COP Tj = Tbiv
4.05
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
1073 kWh
1557 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
11.78 kW
11.53 kW
ηs
154 %
120 %
Prated
11.78 kW
11.53 kW
SCOP
3.93
3.08
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.13 kW
6.98 kW
COP Tj = -7°C
3.47
2.73
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.51 kW
4.20 kW
COP Tj = +2°C
5.32
4.07
Cdh Tj = +2 °C
0.984
0.987
Pdh Tj = +7°C
3.06 kW
2.84 kW
COP Tj = +7°C
7.24
5.15
Cdh Tj = +7 °C
0.968
0.975
Pdh Tj = 12°C
3.18 kW
3.24 kW
COP Tj = 12°C
8.02
6.47
Cdh Tj = +12 °C
0.966
0.973
Pdh Tj = Tbiv
7.13 kW
6.98 kW
COP Tj = Tbiv
3.47
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11.16 kW
10.93 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
7398 kWh
9226 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
8.37 kW
7.62 kW
ηs
195 %
140 %
Prated
8.37 kW
7.62 kW
SCOP
4.95
3.57
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.40 kW
6.74 kW
COP Tj = -7°C
3.10
2.29
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
4.54 kW
4.22 kW
COP Tj = +2°C
4.80
3.51
Cdh Tj = +2 °C
0.986
0.989
Pdh Tj = +7°C
2.94 kW
2.74 kW
COP Tj = +7°C
6.61
4.36
Cdh Tj = +7 °C
0.969
0.978
Pdh Tj = 12°C
3.16 kW
3.28 kW
COP Tj = 12°C
8.15
6.50
Cdh Tj = +12 °C
0.965
0.973
Pdh Tj = Tbiv
7.40 kW
6.74 kW
COP Tj = Tbiv
3.10
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.86 kW
2.72 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
3490 kWh
4405 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
5.80 kW
El input
1.67 kW
1.97 kW
COP
4.80
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.26 kW
1.49 kW
Cooling capacity
7
7.00
EER
3.10
4.70
EN 14825
+7°C/+12°C
Pdesignc
7 kW
SEER
4.64
Pdc Tj = 35°C
7 kW
EER Tj = 35°C
3.1
Pdc Tj = 30°C
5.17 kW
EER Tj = 30°C
4.13
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
3.32 kW
EER Tj = 25°C
4.89
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
3.19 kW
EER Tj = 20°C
6.85
Cdc Tj = 20 °C
0.97
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
1381 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
4.93 kW
4.48 kW
ηs
242 %
151 %
Prated
4.93 kW
4.48 kW
SCOP
6.14
3.84
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
4.93 kW
4.48 kW
COP Tj = +2°C
4.05
2.53
Cdh Tj = +2 °C
0.989
0.992
Pdh Tj = +7°C
3.10 kW
2.81 kW
COP Tj = +7°C
5.70
3.08
Cdh Tj = +7 °C
0.975
0.985
Pdh Tj = 12°C
3.28 kW
3.16 kW
COP Tj = 12°C
7.86
5.45
Cdh Tj = +12 °C
0.967
0.977
Pdh Tj = Tbiv
4.93 kW
4.48 kW
COP Tj = Tbiv
4.05
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
1073 kWh
1557 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
11.78 kW
11.53 kW
ηs
154 %
120 %
Prated
11.78 kW
11.53 kW
SCOP
3.93
3.08
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.13 kW
6.98 kW
COP Tj = -7°C
3.47
2.73
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.51 kW
4.20 kW
COP Tj = +2°C
5.32
4.07
Cdh Tj = +2 °C
0.984
0.987
Pdh Tj = +7°C
3.06 kW
2.84 kW
COP Tj = +7°C
7.24
5.15
Cdh Tj = +7 °C
0.968
0.975
Pdh Tj = 12°C
3.18 kW
3.24 kW
COP Tj = 12°C
8.02
6.47
Cdh Tj = +12 °C
0.966
0.973
Pdh Tj = Tbiv
7.13 kW
6.98 kW
COP Tj = Tbiv
3.47
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11.16 kW
10.93 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
7398 kWh
9226 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
8.37 kW
7.62 kW
ηs
195 %
140 %
Prated
8.37 kW
7.62 kW
SCOP
4.95
3.57
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.40 kW
6.74 kW
COP Tj = -7°C
3.10
2.29
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
4.54 kW
4.22 kW
COP Tj = +2°C
4.80
3.51
Cdh Tj = +2 °C
0.986
0.989
Pdh Tj = +7°C
2.94 kW
2.74 kW
COP Tj = +7°C
6.61
4.36
Cdh Tj = +7 °C
0.969
0.978
Pdh Tj = 12°C
3.16 kW
3.28 kW
COP Tj = 12°C
8.15
6.50
Cdh Tj = +12 °C
0.965
0.973
Pdh Tj = Tbiv
7.40 kW
6.74 kW
COP Tj = Tbiv
3.10
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.86 kW
2.72 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
3490 kWh
4405 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
5.80 kW
El input
1.67 kW
1.97 kW
COP
4.80
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.26 kW
1.49 kW
Cooling capacity
7
7.00
EER
3.10
4.70
EN 14825
+7°C/+12°C
Pdesignc
7 kW
SEER
4.64
Pdc Tj = 35°C
7 kW
EER Tj = 35°C
3.1
Pdc Tj = 30°C
5.17 kW
EER Tj = 30°C
4.13
Cdc Tj = 30 °C
0.99
Pdc Tj = 25°C
3.32 kW
EER Tj = 25°C
4.89
Cdc Tj = 25 °C
0.98
Pdc Tj = 20°C
3.19 kW
EER Tj = 20°C
6.85
Cdc Tj = 20 °C
0.97
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
1381 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
4.93 kW
4.48 kW
ηs
242 %
151 %
Prated
4.93 kW
4.48 kW
SCOP
6.14
3.84
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
4.93 kW
4.48 kW
COP Tj = +2°C
4.05
2.53
Cdh Tj = +2 °C
0.989
0.992
Pdh Tj = +7°C
3.10 kW
2.81 kW
COP Tj = +7°C
5.70
3.08
Cdh Tj = +7 °C
0.975
0.985
Pdh Tj = 12°C
3.28 kW
3.16 kW
COP Tj = 12°C
7.86
5.45
Cdh Tj = +12 °C
0.967
0.977
Pdh Tj = Tbiv
4.93 kW
4.48 kW
COP Tj = Tbiv
4.05
2.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
1073 kWh
1557 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
11.78 kW
11.53 kW
ηs
154 %
120 %
Prated
11.78 kW
11.53 kW
SCOP
3.93
3.08
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.13 kW
6.98 kW
COP Tj = -7°C
3.47
2.73
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.51 kW
4.20 kW
COP Tj = +2°C
5.32
4.07
Cdh Tj = +2 °C
0.984
0.987
Pdh Tj = +7°C
3.06 kW
2.84 kW
COP Tj = +7°C
7.24
5.15
Cdh Tj = +7 °C
0.968
0.975
Pdh Tj = 12°C
3.18 kW
3.24 kW
COP Tj = 12°C
8.02
6.47
Cdh Tj = +12 °C
0.966
0.973
Pdh Tj = Tbiv
7.13 kW
6.98 kW
COP Tj = Tbiv
3.47
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11.16 kW
10.93 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
7398 kWh
9226 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
8.37 kW
7.62 kW
ηs
195 %
140 %
Prated
8.37 kW
7.62 kW
SCOP
4.95
3.57
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.40 kW
6.74 kW
COP Tj = -7°C
3.10
2.29
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
4.54 kW
4.22 kW
COP Tj = +2°C
4.80
3.51
Cdh Tj = +2 °C
0.986
0.989
Pdh Tj = +7°C
2.94 kW
2.74 kW
COP Tj = +7°C
6.61
4.36
Cdh Tj = +7 °C
0.969
0.978
Pdh Tj = 12°C
3.16 kW
3.28 kW
COP Tj = 12°C
8.15
6.50
Cdh Tj = +12 °C
0.965
0.973
Pdh Tj = Tbiv
7.40 kW
6.74 kW
COP Tj = Tbiv
3.10
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.86 kW
2.72 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
3490 kWh
4405 kWh