1,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.95 kW
El input
0.69 kW
1.09 kW
COP
5.10
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.03 kW
Cooling capacity
3.5
EN 14825
+7°C/+12°C
Pdesignc
3.5 kW
SEER
4.87
Pdc Tj = 35°C
3.5 kW
EER Tj = 35°C
3
Pdc Tj = 30°C
2.58 kW
EER Tj = 30°C
4.33
Cdc Tj = 30 °C
0.98
Pdc Tj = 25°C
1.72 kW
EER Tj = 25°C
5.86
Cdc Tj = 25 °C
0.95
Pdc Tj = 20°C
1.79 kW
EER Tj = 20°C
7.24
Cdc Tj = 20 °C
0.94
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
628 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.63 kW
ηs
192 %
134 %
Prated
5.20 kW
4.63 kW
SCOP
4.89
3.43
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.60 kW
4.10 kW
COP Tj = -7°C
3.21
2.28
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
2.88 kW
2.63 kW
COP Tj = +2°C
4.66
3.35
Cdh Tj = +2 °C
0.979
0.983
Pdh Tj = +7°C
1.85 kW
1.76 kW
COP Tj = +7°C
6.56
4.22
Cdh Tj = +7 °C
0.954
0.969
Pdh Tj = 12°C
1.92 kW
1.88 kW
COP Tj = 12°C
8.49
6.30
Cdh Tj = +12 °C
0.942
0.956
Pdh Tj = Tbiv
4.60 kW
4.10 kW
COP Tj = Tbiv
3.21
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.993
WTOL
60 °C
60 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
13 W
13 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.17 kW
2.17 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
2198 kWh
2790 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.30
Heating up time
01:52 h:min
Standby power input
32.0 W
Reference hot water temperature
53 °C
Mixed water at 40°C
244 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
3.80 kW
El input
1.00 kW
1.36 kW
COP
5.00
2.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.75 kW
Cooling capacity
5
EER
2.85
4.56
EN 14825
+7°C/+12°C
Pdesignc
5 kW
SEER
4.85
Pdc Tj = 35°C
5 kW
EER Tj = 35°C
2.85
Pdc Tj = 30°C
3.77 kW
EER Tj = 30°C
4.25
Cdc Tj = 30 °C
0.98
Pdc Tj = 25°C
2.32 kW
EER Tj = 25°C
5.38
Cdc Tj = 25 °C
0.97
Pdc Tj = 20°C
1.87 kW
EER Tj = 20°C
7.85
Cdc Tj = 20 °C
0.94
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
925 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.65 kW
5.65 kW
ηs
183 %
136 %
Prated
5.65 kW
5.65 kW
SCOP
4.66
3.48
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
3.10
2.28
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
3.11 kW
3.11 kW
COP Tj = +2°C
4.32
3.30
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
1.96 kW
2.19 kW
COP Tj = +7°C
6.48
4.58
Cdh Tj = +7 °C
0.955
0.972
Pdh Tj = 12°C
1.86 kW
1.84 kW
COP Tj = 12°C
8.41
6.33
Cdh Tj = +12 °C
0.939
0.953
Pdh Tj = Tbiv
5.00 kW
5.00 kW
COP Tj = Tbiv
3.10
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.69 kW
3.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.30
1.54
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
60 °C
60 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
13 W
13 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.96 kW
2.47 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
2505 kWh
3360 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.30
Heating up time
01:30 h:min
Standby power input
32.0 W
Reference hot water temperature
53 °C
Mixed water at 40°C
244 l