3,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.19 kW
4.20 kW
El input
0.84 kW
1.34 kW
COP
5.01
3.13
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
214 %
168 %
Prated
12.03 kW
11.99 kW
SCOP
5.55
4.39
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.03 kW
11.99 kW
COP Tj = +2°C
4.53
3.29
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
7.71 kW
7.69 kW
COP Tj = +7°C
5.51
4.12
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
3.41 kW
3.41 kW
COP Tj = 12°C
6.14
5.10
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
12.03 kW
11.99 kW
COP Tj = Tbiv
4.53
3.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.03 kW
11.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.53
3.29
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2896 kWh
3650 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
174 %
Prated
12.03 kW
11.99 kW
SCOP
5.80
4.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.26 kW
7.24 kW
COP Tj = -7°C
5.69
4.31
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.41 kW
4.40 kW
COP Tj = +2°C
6.16
4.91
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.82 kW
2.82 kW
COP Tj = +7°C
6.19
5.16
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.29 kW
2.23 kW
COP Tj = 12°C
6.12
5.40
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
12.03 kW
11.99 kW
COP Tj = Tbiv
4.53
3.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.03 kW
11.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.53
3.29
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5108 kWh
6485 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
216 %
169 %
Prated
12.03 kW
11.99 kW
SCOP
5.59
4.42
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.61 kW
10.59 kW
COP Tj = -7°C
4.81
3.55
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
6.45 kW
6.44 kW
COP Tj = +2°C
5.72
4.49
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
4.14 kW
4.13 kW
COP Tj = +7°C
6.12
4.99
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.30 kW
2.21 kW
COP Tj = 12°C
6.29
5.25
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
12.03 kW
11.99 kW
COP Tj = Tbiv
4.53
3.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.03 kW
11.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.53
3.29
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4445 kWh
5607 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.18 kW
4.72 kW
El input
1.07 kW
1.48 kW
COP
4.86
3.18
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
167 %
Prated
14.46 kW
13.77 kW
SCOP
5.41
4.37
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14.46 kW
13.77 kW
COP Tj = +2°C
4.30
3.26
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
9.27 kW
8.83 kW
COP Tj = +7°C
5.13
3.99
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.11 kW
3.92 kW
COP Tj = 12°C
6.17
5.16
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.46 kW
13.77 kW
COP Tj = Tbiv
4.30
3.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.46 kW
13.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.30
3.26
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3573 kWh
4211 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
174 %
Prated
14.46 kW
13.77 kW
SCOP
5.66
4.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.73 kW
8.32 kW
COP Tj = -7°C
5.32
4.24
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
5.30 kW
5.05 kW
COP Tj = +2°C
6.15
4.94
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.40 kW
3.24 kW
COP Tj = +7°C
6.27
5.24
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.29 kW
2.23 kW
COP Tj = 12°C
6.12
5.44
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.46 kW
13.77 kW
COP Tj = Tbiv
4.30
3.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.46 kW
13.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.30
3.26
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6298 kWh
7451 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210 %
168 %
Prated
14.46 kW
13.77 kW
SCOP
5.44
4.39
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.77 kW
12.16 kW
COP Tj = -7°C
4.46
3.40
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
7.76 kW
7.40 kW
COP Tj = +2°C
5.51
4.44
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
4.98 kW
4.75 kW
COP Tj = +7°C
6.13
5.03
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.29 kW
2.22 kW
COP Tj = 12°C
6.18
5.31
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.46 kW
13.77 kW
COP Tj = Tbiv
4.30
3.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.46 kW
13.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.30
3.26
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5489 kWh
6476 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.19 kW
4.20 kW
El input
0.84 kW
1.34 kW
COP
5.01
3.13
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
214 %
168 %
Prated
12.03 kW
11.99 kW
SCOP
5.55
4.39
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.03 kW
11.99 kW
COP Tj = +2°C
4.53
3.29
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
7.71 kW
7.69 kW
COP Tj = +7°C
5.51
4.12
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
3.41 kW
3.41 kW
COP Tj = 12°C
6.14
5.10
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
12.03 kW
11.99 kW
COP Tj = Tbiv
4.53
3.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.03 kW
11.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.53
3.29
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2896 kWh
3650 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
174 %
Prated
12.03 kW
11.99 kW
SCOP
5.80
4.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.26 kW
7.24 kW
COP Tj = -7°C
5.69
4.31
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.41 kW
4.40 kW
COP Tj = +2°C
6.16
4.91
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.82 kW
2.82 kW
COP Tj = +7°C
6.19
5.16
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.29 kW
2.23 kW
COP Tj = 12°C
6.12
5.40
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
12.03 kW
11.99 kW
COP Tj = Tbiv
4.53
3.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.03 kW
11.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.53
3.29
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5108 kWh
6485 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
216 %
169 %
Prated
12.03 kW
11.99 kW
SCOP
5.59
4.42
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.61 kW
10.59 kW
COP Tj = -7°C
4.81
3.55
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
6.45 kW
6.44 kW
COP Tj = +2°C
5.72
4.49
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
4.14 kW
4.13 kW
COP Tj = +7°C
6.12
4.99
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.30 kW
2.21 kW
COP Tj = 12°C
6.29
5.25
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
12.03 kW
11.99 kW
COP Tj = Tbiv
4.53
3.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.03 kW
11.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.53
3.29
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4445 kWh
5607 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.18 kW
4.72 kW
El input
1.07 kW
1.48 kW
COP
4.86
3.18
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
167 %
Prated
14.46 kW
13.77 kW
SCOP
5.41
4.37
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14.46 kW
13.77 kW
COP Tj = +2°C
4.30
3.26
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
9.27 kW
8.83 kW
COP Tj = +7°C
5.13
3.99
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.11 kW
3.92 kW
COP Tj = 12°C
6.17
5.16
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.46 kW
13.77 kW
COP Tj = Tbiv
4.30
3.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.46 kW
13.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.30
3.26
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3573 kWh
4211 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
174 %
Prated
14.46 kW
13.77 kW
SCOP
5.66
4.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.73 kW
8.32 kW
COP Tj = -7°C
5.32
4.24
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
5.30 kW
5.05 kW
COP Tj = +2°C
6.15
4.94
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.40 kW
3.24 kW
COP Tj = +7°C
6.27
5.24
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.29 kW
2.23 kW
COP Tj = 12°C
6.12
5.44
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.46 kW
13.77 kW
COP Tj = Tbiv
4.30
3.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.46 kW
13.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.30
3.26
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6298 kWh
7451 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210 %
168 %
Prated
14.46 kW
13.77 kW
SCOP
5.44
4.39
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.77 kW
12.16 kW
COP Tj = -7°C
4.46
3.40
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
7.76 kW
7.40 kW
COP Tj = +2°C
5.51
4.44
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
4.98 kW
4.75 kW
COP Tj = +7°C
6.13
5.03
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.29 kW
2.22 kW
COP Tj = 12°C
6.18
5.31
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
14.46 kW
13.77 kW
COP Tj = Tbiv
4.30
3.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.46 kW
13.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.30
3.26
WTOL
75 °C
75 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5489 kWh
6476 kWh