Certificate holders

Subtype

Buderus Logatherm WPLS4/6.2

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W0140
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus Logatherm WPLS4/6.2
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,600 kg

Certification Date
18.07.2017
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 8

Models

Buderus Logatherm WPLS4.2 RE
Configure model
Model name
Buderus Logatherm WPLS4.2 RE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

6.80 kW

El input

1.96 kW

2.99 kW

COP

1.77

2.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

149 %

Prated

6.17 kW

4.95 kW

SCOP

5.46

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.17 kW

4.94 kW

COP Tj = +2°C

3.53

2.07

Cdh Tj = +2 °C

0.990

0.993

Pdh Tj = +7°C

3.96 kW

3.16 kW

COP Tj = +7°C

5.11

3.36

Cdh Tj = +7 °C

0.978

0.982

Pdh Tj = 12°C

3.99 kW

3.73 kW

COP Tj = 12°C

6.59

4.99

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

6.17 kW

4.94 kW

COP Tj = Tbiv

3.53

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.17 kW

4.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.993

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1510 kWh

1737 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

106 %

Prated

6.74 kW

5.44 kW

SCOP

3.69

2.72

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.08 kW

3.27 kW

COP Tj = -7°C

3.44

2.28

Cdh Tj = -7 °C

0.986

0.988

Pdh Tj = +2°C

3.08 kW

2.81 kW

COP Tj = +2°C

4.79

3.40

Cdh Tj = +2 °C

0.974

0.979

Pdh Tj = +7°C

3.51 kW

3.29 kW

COP Tj = +7°C

5.72

4.35

Cdh Tj = +7 °C

0.972

0.978

Pdh Tj = 12°C

4.01 kW

3.83 kW

COP Tj = 12°C

6.62

5.61

Cdh Tj = +12 °C

0.972

0.975

Pdh Tj = Tbiv

5.50 kW

4.44 kW

COP Tj = Tbiv

2.81

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.50 kW

4.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

1.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.992

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.74 kW

5.44 kW

Annual energy consumption Qhe

4500 kWh

4933 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.50

4.43

COP Tj = -15°C (if TOL<-20°C)

2.81

1.99

Cdh Tj = -15 °C

0.991

0.992

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

122 %

Prated

5.84 kW

4.78 kW

SCOP

4.46

3.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.19 kW

4.20 kW

COP Tj = -7°C

3.04

1.91

Cdh Tj = -7 °C

0.990

0.992

Pdh Tj = +2°C

3.01 kW

2.52 kW

COP Tj = +2°C

4.53

3.09

Cdh Tj = +2 °C

0.974

0.979

Pdh Tj = +7°C

3.49 kW

3.16 kW

COP Tj = +7°C

5.57

4.08

Cdh Tj = +7 °C

0.973

0.978

Pdh Tj = 12°C

3.49 kW

3.81 kW

COP Tj = 12°C

5.57

5.35

Cdh Tj = +12 °C

0.973

0.976

Pdh Tj = Tbiv

5.84 kW

4.77 kW

COP Tj = Tbiv

2.68

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

4.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2708 kWh

3163 kWh

Buderus Logatherm WPLS4.2 RB
Configure model
Model name
Buderus Logatherm WPLS4.2 RB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

6.80 kW

El input

1.96 kW

2.99 kW

COP

1.77

2.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

149 %

Prated

6.17 kW

4.95 kW

SCOP

5.46

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.17 kW

4.94 kW

COP Tj = +2°C

3.53

2.07

Cdh Tj = +2 °C

0.990

0.993

Pdh Tj = +7°C

3.96 kW

3.16 kW

COP Tj = +7°C

5.11

3.36

Cdh Tj = +7 °C

0.978

0.982

Pdh Tj = 12°C

3.99 kW

3.73 kW

COP Tj = 12°C

6.59

4.99

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

6.17 kW

4.94 kW

COP Tj = Tbiv

3.53

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.17 kW

4.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.993

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1510 kWh

1737 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

106 %

Prated

6.74 kW

5.44 kW

SCOP

3.69

2.72

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.08 kW

3.27 kW

COP Tj = -7°C

3.44

2.28

Cdh Tj = -7 °C

0.986

0.988

Pdh Tj = +2°C

3.08 kW

2.81 kW

COP Tj = +2°C

4.79

3.40

Cdh Tj = +2 °C

0.974

0.979

Pdh Tj = +7°C

3.51 kW

3.29 kW

COP Tj = +7°C

5.72

4.35

Cdh Tj = +7 °C

0.972

0.978

Pdh Tj = 12°C

4.01 kW

3.83 kW

COP Tj = 12°C

6.62

5.61

Cdh Tj = +12 °C

0.972

0.975

Pdh Tj = Tbiv

5.50 kW

4.44 kW

COP Tj = Tbiv

2.81

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.50 kW

4.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

1.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.992

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4500 kWh

4933 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.50

4.43

COP Tj = -15°C (if TOL<-20°C)

2.81

1.99

Cdh Tj = -15 °C

0.991

0.992

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

122 %

Prated

5.84 kW

4.78 kW

SCOP

4.46

3.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.19 kW

4.20 kW

COP Tj = -7°C

3.04

1.91

Cdh Tj = -7 °C

0.990

0.992

Pdh Tj = +2°C

3.01 kW

2.52 kW

COP Tj = +2°C

4.53

3.09

Cdh Tj = +2 °C

0.974

0.979

Pdh Tj = +7°C

3.49 kW

3.16 kW

COP Tj = +7°C

5.57

4.08

Cdh Tj = +7 °C

0.973

0.978

Pdh Tj = 12°C

3.49 kW

3.81 kW

COP Tj = 12°C

5.57

5.35

Cdh Tj = +12 °C

0.973

0.976

Pdh Tj = Tbiv

5.84 kW

4.77 kW

COP Tj = Tbiv

2.68

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

4.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2708 kWh

3163 kWh

Buderus Logatherm WPLS4.2 RT
Configure model
Model name
Buderus Logatherm WPLS4.2 RT
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

6.80 kW

El input

1.96 kW

2.99 kW

COP

1.77

2.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

149 %

Prated

6.17 kW

4.95 kW

SCOP

5.46

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.17 kW

4.94 kW

COP Tj = +2°C

3.53

2.07

Cdh Tj = +2 °C

0.990

0.993

Pdh Tj = +7°C

3.96 kW

3.16 kW

COP Tj = +7°C

5.11

3.36

Cdh Tj = +7 °C

0.978

0.982

Pdh Tj = 12°C

3.99 kW

3.73 kW

COP Tj = 12°C

6.59

4.99

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

6.17 kW

4.94 kW

COP Tj = Tbiv

3.53

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.17 kW

4.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.993

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1510 kWh

1737 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

106 %

Prated

6.74 kW

5.44 kW

SCOP

3.69

2.72

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.08 kW

3.27 kW

COP Tj = -7°C

3.44

2.28

Cdh Tj = -7 °C

0.986

0.988

Pdh Tj = +2°C

3.08 kW

2.81 kW

COP Tj = +2°C

4.79

3.40

Cdh Tj = +2 °C

0.974

0.979

Pdh Tj = +7°C

3.51 kW

3.29 kW

COP Tj = +7°C

5.72

4.35

Cdh Tj = +7 °C

0.972

0.978

Pdh Tj = 12°C

4.01 kW

3.83 kW

COP Tj = 12°C

6.62

5.61

Cdh Tj = +12 °C

0.972

0.975

Pdh Tj = Tbiv

5.50 kW

4.44 kW

COP Tj = Tbiv

2.81

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.50 kW

4.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

1.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.992

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.74 kW

5.44 kW

Annual energy consumption Qhe

4500 kWh

4933 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.50

1.99

COP Tj = -15°C (if TOL<-20°C)

2.81

1.99

Cdh Tj = -15 °C

0.991

0.992

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

122 %

Prated

5.84 kW

4.78 kW

SCOP

4.46

3.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.19 kW

4.20 kW

COP Tj = -7°C

3.04

1.91

Cdh Tj = -7 °C

0.990

0.992

Pdh Tj = +2°C

3.01 kW

2.52 kW

COP Tj = +2°C

4.53

3.09

Cdh Tj = +2 °C

0.974

0.979

Pdh Tj = +7°C

3.49 kW

3.16 kW

COP Tj = +7°C

5.57

4.08

Cdh Tj = +7 °C

0.973

0.978

Pdh Tj = 12°C

3.49 kW

3.81 kW

COP Tj = 12°C

5.57

5.35

Cdh Tj = +12 °C

0.973

0.976

Pdh Tj = Tbiv

5.84 kW

4.77 kW

COP Tj = Tbiv

2.68

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

4.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2708 kWh

3163 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.65

Heating up time

01:44 h:min

Standby power input

51.0 W

Reference hot water temperature

51.9 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

72 %

COP

1.64

Heating up time

02:43 h:min

Standby power input

109.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

94 %

COP

2.22

Heating up time

02:11 h:min

Standby power input

58.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

254 l

Buderus Logatherm WPLS4.2 RTS
Configure model
Model name
Buderus Logatherm WPLS4.2 RTS
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

6.80 kW

El input

1.96 kW

2.99 kW

COP

1.77

2.27

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

149 %

Prated

6.17 kW

4.95 kW

SCOP

5.46

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.17 kW

4.94 kW

COP Tj = +2°C

3.53

2.07

Cdh Tj = +2 °C

0.990

0.993

Pdh Tj = +7°C

3.96 kW

3.16 kW

COP Tj = +7°C

5.11

3.36

Cdh Tj = +7 °C

0.978

0.982

Pdh Tj = 12°C

3.99 kW

3.73 kW

COP Tj = 12°C

6.59

4.99

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

6.17 kW

4.94 kW

COP Tj = Tbiv

3.53

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.17 kW

4.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.993

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1510 kWh

1737 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

106 %

Prated

6.74 kW

5.44 kW

SCOP

3.69

2.72

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.08 kW

3.27 kW

COP Tj = -7°C

3.44

2.28

Cdh Tj = -7 °C

0.986

0.988

Pdh Tj = +2°C

3.08 kW

2.81 kW

COP Tj = +2°C

4.79

3.40

Cdh Tj = +2 °C

0.974

0.979

Pdh Tj = +7°C

3.51 kW

3.29 kW

COP Tj = +7°C

5.72

4.35

Cdh Tj = +7 °C

0.972

0.978

Pdh Tj = 12°C

4.01 kW

3.83 kW

COP Tj = 12°C

6.62

5.61

Cdh Tj = +12 °C

0.972

0.975

Pdh Tj = Tbiv

5.50 kW

4.44 kW

COP Tj = Tbiv

2.81

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.50 kW

4.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

1.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.992

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.74 kW

5.44 kW

Annual energy consumption Qhe

4500 kWh

4933 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.50

4.43

COP Tj = -15°C (if TOL<-20°C)

2.81

1.99

Cdh Tj = -15 °C

0.991

0.992

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

122 %

Prated

5.84 kW

4.78 kW

SCOP

4.46

3.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.19 kW

4.20 kW

COP Tj = -7°C

3.04

1.91

Cdh Tj = -7 °C

0.990

0.992

Pdh Tj = +2°C

3.01 kW

2.52 kW

COP Tj = +2°C

4.53

3.09

Cdh Tj = +2 °C

0.974

0.979

Pdh Tj = +7°C

3.49 kW

3.16 kW

COP Tj = +7°C

5.57

4.08

Cdh Tj = +7 °C

0.973

0.978

Pdh Tj = 12°C

3.49 kW

3.81 kW

COP Tj = 12°C

5.57

5.35

Cdh Tj = +12 °C

0.973

0.976

Pdh Tj = Tbiv

5.84 kW

4.77 kW

COP Tj = Tbiv

2.68

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

4.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2708 kWh

3163 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.34

Heating up time

01:42 h:min

Standby power input

63.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

247 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

70 %

COP

1.61

Heating up time

01:56 h:min

Standby power input

111.2 W

Reference hot water temperature

50.5 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

87 %

COP

2.04

Heating up time

02:08 h:min

Standby power input

62.2 W

Reference hot water temperature

51.1 °C

Mixed water at 40°C

238 l

Buderus Logatherm WPLS6.2 RE
Configure model
Model name
Buderus Logatherm WPLS6.2 RE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

7.62 kW

El input

1.96 kW

3.46 kW

COP

1.77

2.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

148 %

Prated

6.39 kW

5.81 kW

SCOP

5.45

3.77

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.39 kW

5.81 kW

COP Tj = +2°C

3.10

2.02

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

4.22 kW

3.72 kW

COP Tj = +7°C

5.21

3.36

Cdh Tj = +7 °C

0.979

0.985

Pdh Tj = 12°C

4.01 kW

3.72 kW

COP Tj = 12°C

6.57

4.84

Cdh Tj = +12 °C

0.972

0.978

Pdh Tj = Tbiv

6.39 kW

5.81 kW

COP Tj = Tbiv

3.10

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.39 kW

5.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1566 kWh

2058 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

141 %

109 %

Prated

7.30 kW

6.80 kW

SCOP

3.59

2.80

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.40 kW

4.12 kW

COP Tj = -7°C

3.29

2.37

Cdh Tj = -7 °C

0.987

0.990

Pdh Tj = +2°C

3.00 kW

2.73 kW

COP Tj = +2°C

4.74

3.55

Cdh Tj = +2 °C

0.973

0.978

Pdh Tj = +7°C

3.47 kW

3.26 kW

COP Tj = +7°C

5.56

4.38

Cdh Tj = +7 °C

0.973

0.977

Pdh Tj = 12°C

4.03 kW

3.87 kW

COP Tj = 12°C

6.74

5.47

Cdh Tj = +12 °C

0.972

0.976

Pdh Tj = Tbiv

6.00 kW

5.55 kW

COP Tj = Tbiv

2.43

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.55 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.30 kW

6.80 kW

Annual energy consumption Qhe

5007 kWh

5992 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.00

5.55

COP Tj = -15°C (if TOL<-20°C)

2.43

1.86

Cdh Tj = -15 °C

0.993

0.994

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

121 %

Prated

6.80 kW

5.31 kW

SCOP

4.24

3.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

4.78 kW

COP Tj = -7°C

2.64

1.90

Cdh Tj = -7 °C

0.992

0.993

Pdh Tj = +2°C

3.58 kW

2.80 kW

COP Tj = +2°C

4.22

3.11

Cdh Tj = +2 °C

0.980

0.981

Pdh Tj = +7°C

3.49 kW

3.16 kW

COP Tj = +7°C

5.51

3.96

Cdh Tj = +7 °C

0.973

0.979

Pdh Tj = 12°C

3.91 kW

3.81 kW

COP Tj = 12°C

6.40

5.22

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

6.80 kW

5.31 kW

COP Tj = Tbiv

2.54

1.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.80 kW

5.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3311 kWh

3535 kWh

Buderus Logatherm WPLS6.2 RB
Configure model
Model name
Buderus Logatherm WPLS6.2 RB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

7.62 kW

El input

1.96 kW

3.46 kW

COP

1.77

2.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

148 %

Prated

6.39 kW

5.81 kW

SCOP

5.45

3.77

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.39 kW

5.81 kW

COP Tj = +2°C

3.10

2.02

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

4.22 kW

3.72 kW

COP Tj = +7°C

5.21

3.36

Cdh Tj = +7 °C

0.979

0.985

Pdh Tj = 12°C

4.01 kW

3.72 kW

COP Tj = 12°C

6.57

4.84

Cdh Tj = +12 °C

0.972

0.978

Pdh Tj = Tbiv

6.39 kW

5.81 kW

COP Tj = Tbiv

3.10

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.39 kW

5.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1566 kWh

2058 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

141 %

109 %

Prated

7.30 kW

6.80 kW

SCOP

3.59

2.80

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.40 kW

4.12 kW

COP Tj = -7°C

3.29

2.37

Cdh Tj = -7 °C

0.987

0.990

Pdh Tj = +2°C

3.00 kW

2.73 kW

COP Tj = +2°C

4.74

3.55

Cdh Tj = +2 °C

0.973

0.978

Pdh Tj = +7°C

3.47 kW

3.26 kW

COP Tj = +7°C

5.56

4.38

Cdh Tj = +7 °C

0.973

0.977

Pdh Tj = 12°C

4.03 kW

3.87 kW

COP Tj = 12°C

6.74

5.47

Cdh Tj = +12 °C

0.972

0.976

Pdh Tj = Tbiv

6.00 kW

5.55 kW

COP Tj = Tbiv

2.43

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.55 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5007 kWh

5992 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.00

5.55

COP Tj = -15°C (if TOL<-20°C)

2.43

1.86

Cdh Tj = -15 °C

0.993

0.994

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

121 %

Prated

6.80 kW

5.31 kW

SCOP

4.24

3.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

4.78 kW

COP Tj = -7°C

2.64

1.90

Cdh Tj = -7 °C

0.992

0.993

Pdh Tj = +2°C

3.58 kW

2.80 kW

COP Tj = +2°C

4.22

3.11

Cdh Tj = +2 °C

0.980

0.981

Pdh Tj = +7°C

3.49 kW

3.16 kW

COP Tj = +7°C

5.51

3.96

Cdh Tj = +7 °C

0.973

0.979

Pdh Tj = 12°C

3.91 kW

3.81 kW

COP Tj = 12°C

6.40

5.22

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

6.80 kW

5.31 kW

COP Tj = Tbiv

2.54

1.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.80 kW

5.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3311 kWh

3535 kWh

Buderus Logatherm WPLS6.2 RT
Configure model
Model name
Buderus Logatherm WPLS6.2 RT
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

7.62 kW

El input

1.96 kW

3.46 kW

COP

1.77

2.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

148 %

Prated

6.39 kW

5.81 kW

SCOP

5.45

3.77

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.39 kW

5.81 kW

COP Tj = +2°C

3.10

2.02

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

4.22 kW

3.72 kW

COP Tj = +7°C

5.21

3.36

Cdh Tj = +7 °C

0.979

0.985

Pdh Tj = 12°C

4.01 kW

3.72 kW

COP Tj = 12°C

6.57

4.84

Cdh Tj = +12 °C

0.972

0.978

Pdh Tj = Tbiv

6.39 kW

5.81 kW

COP Tj = Tbiv

3.10

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.39 kW

5.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1566 kWh

2058 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

141 %

109 %

Prated

7.30 kW

6.80 kW

SCOP

3.59

2.80

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.40 kW

4.12 kW

COP Tj = -7°C

3.29

2.37

Cdh Tj = -7 °C

0.987

0.990

Pdh Tj = +2°C

3.00 kW

2.73 kW

COP Tj = +2°C

4.74

3.55

Cdh Tj = +2 °C

0.973

0.978

Pdh Tj = +7°C

3.47 kW

3.26 kW

COP Tj = +7°C

5.56

4.38

Cdh Tj = +7 °C

0.973

0.977

Pdh Tj = 12°C

4.03 kW

3.87 kW

COP Tj = 12°C

6.74

5.47

Cdh Tj = +12 °C

0.972

0.976

Pdh Tj = Tbiv

6.00 kW

5.55 kW

COP Tj = Tbiv

2.43

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.55 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.30 kW

6.80 kW

Annual energy consumption Qhe

5007 kWh

5992 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.00

1.86

COP Tj = -15°C (if TOL<-20°C)

2.43

1.86

Cdh Tj = -15 °C

0.993

0.994

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

121 %

Prated

6.80 kW

5.31 kW

SCOP

4.24

3.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

4.78 kW

COP Tj = -7°C

2.64

1.90

Cdh Tj = -7 °C

0.992

0.993

Pdh Tj = +2°C

3.58 kW

2.80 kW

COP Tj = +2°C

4.22

3.11

Cdh Tj = +2 °C

0.980

0.981

Pdh Tj = +7°C

3.49 kW

3.16 kW

COP Tj = +7°C

5.51

3.96

Cdh Tj = +7 °C

0.973

0.979

Pdh Tj = 12°C

3.91 kW

3.81 kW

COP Tj = 12°C

6.40

5.22

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

6.80 kW

5.31 kW

COP Tj = Tbiv

2.54

1.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.80 kW

5.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3311 kWh

3535 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.65

Heating up time

01:44 h:min

Standby power input

51.0 W

Reference hot water temperature

51.9 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

72 %

COP

1.64

Heating up time

02:43 h:min

Standby power input

109.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

94 %

COP

2.22

Heating up time

02:11 h:min

Standby power input

58.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

254 l

Buderus Logatherm WPLS6.2 RTS
Configure model
Model name
Buderus Logatherm WPLS6.2 RTS
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

7.62 kW

El input

1.96 kW

3.46 kW

COP

1.77

2.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

148 %

Prated

6.39 kW

5.81 kW

SCOP

5.45

3.77

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.39 kW

5.81 kW

COP Tj = +2°C

3.10

2.02

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

4.22 kW

3.72 kW

COP Tj = +7°C

5.21

3.36

Cdh Tj = +7 °C

0.979

0.985

Pdh Tj = 12°C

4.01 kW

3.72 kW

COP Tj = 12°C

6.57

4.84

Cdh Tj = +12 °C

0.972

0.978

Pdh Tj = Tbiv

6.39 kW

5.81 kW

COP Tj = Tbiv

3.10

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.39 kW

5.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1566 kWh

2058 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

141 %

109 %

Prated

7.30 kW

6.80 kW

SCOP

3.59

2.80

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.40 kW

4.12 kW

COP Tj = -7°C

3.29

2.37

Cdh Tj = -7 °C

0.987

0.990

Pdh Tj = +2°C

3.00 kW

2.73 kW

COP Tj = +2°C

4.74

3.55

Cdh Tj = +2 °C

0.973

0.978

Pdh Tj = +7°C

3.47 kW

3.26 kW

COP Tj = +7°C

5.56

4.38

Cdh Tj = +7 °C

0.973

0.977

Pdh Tj = 12°C

4.03 kW

3.87 kW

COP Tj = 12°C

6.74

5.47

Cdh Tj = +12 °C

0.972

0.976

Pdh Tj = Tbiv

6.00 kW

5.55 kW

COP Tj = Tbiv

2.43

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.55 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.994

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.30 kW

6.80 kW

Annual energy consumption Qhe

5007 kWh

5992 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.00

5.55

COP Tj = -15°C (if TOL<-20°C)

2.43

1.86

Cdh Tj = -15 °C

0.993

0.994

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

121 %

Prated

6.80 kW

5.31 kW

SCOP

4.24

3.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

4.78 kW

COP Tj = -7°C

2.64

1.90

Cdh Tj = -7 °C

0.992

0.993

Pdh Tj = +2°C

3.58 kW

2.80 kW

COP Tj = +2°C

4.22

3.11

Cdh Tj = +2 °C

0.980

0.981

Pdh Tj = +7°C

3.49 kW

3.16 kW

COP Tj = +7°C

5.51

3.96

Cdh Tj = +7 °C

0.973

0.979

Pdh Tj = 12°C

3.91 kW

3.81 kW

COP Tj = 12°C

6.40

5.22

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

6.80 kW

5.31 kW

COP Tj = Tbiv

2.54

1.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.80 kW

5.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

57 °C

57 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

16 W

16 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3311 kWh

3535 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.34

Heating up time

01:42 h:min

Standby power input

63.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

247 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

70 %

COP

1.61

Heating up time

01:56 h:min

Standby power input

111.2 W

Reference hot water temperature

50.5 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

87 %

COP

2.04

Heating up time

02:08 h:min

Standby power input

62.2 W

Reference hot water temperature

51.1 °C

Mixed water at 40°C

238 l