Certificate holders

Subtype

i-32V5H MIDI 0128 -0132

Certificate Holder
Advantix S.p.A.
Via San Giuseppe Lavoratore, 24
37040 Arcole Verona
Italy
Registration number
ICIM-PDC-000105
Certification Body
ICIM S.p.A.
Subtype title
i-32V5H MIDI 0128 -0132
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

5,100 kg

Certification Date
07.06.2021
Testing basis
V9
Generate PDF Export model CSV
  • Number of models 2

Models

i-32V5H MIDI 0128
Configure model
Model name
i-32V5H MIDI 0128
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

28.00 kW

27.30 kW

El input

6.35 kW

9.99 kW

COP

4.41

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

7.99 kW

Cooling capacity

24.20

EER

3.03

EN 14825

+7°C/+12°C

Pdesignc

24.20 kW

SEER

4.76

Pdc Tj = 35°C

24.20 kW

EER Tj = 35°C

3.03

Pdc Tj = 30°C

17.74 kW

EER Tj = 30°C

4.12

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

11.32 kW

EER Tj = 25°C

5.38

Cdc Tj = 25 °C

0.900

Pdc Tj = 20°C

12.26 kW

EER Tj = 20°C

6.47

Cdc Tj = 20 °C

0.900

Poff

22 W

PTO

0 W

PSB

28 W

PCK

0 W

Annual energy consumption Qce

3037 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

126 %

Prated

25.00 kW

24.00 kW

SCOP

4.29

3.23

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

21.70 kW

20.80 kW

COP Tj = -7°C

2.68

1.93

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

13.20 kW

12.80 kW

COP Tj = +2°C

4.26

3.20

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

11.90 kW

11.50 kW

COP Tj = +7°C

5.39

4.10

Cdh Tj = +7 °C

0.993

0.995

Pdh Tj = 12°C

13.70 kW

13.50 kW

COP Tj = 12°C

7.06

5.77

Cdh Tj = +12 °C

0.992

0.993

Pdh Tj = Tbiv

21.70 kW

20.80 kW

COP Tj = Tbiv

2.68

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.30 kW

18.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

5.70 kW

5.20 kW

Annual energy consumption Qhe

11823 kWh

15056 kWh

i-32V5H MIDI 0132
Configure model
Model name
i-32V5H MIDI 0132
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

32.10 kW

31.80 kW

El input

7.84 kW

12.10 kW

COP

4.09

2.64

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

8.65 kW

Cooling capacity

26.00

EER

3.01

EN 14825

+7°C/+12°C

Pdesignc

26.00 kW

SEER

4.81

Pdc Tj = 35°C

26.00 kW

EER Tj = 35°C

3.01

Pdc Tj = 30°C

19.10 kW

EER Tj = 30°C

4.15

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

12.27 kW

EER Tj = 25°C

5.35

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

12.56 kW

EER Tj = 20°C

6.63

Cdc Tj = 20 °C

0.900

Poff

22 W

PTO

0 W

PSB

28 W

PCK

0 W

Annual energy consumption Qce

3241 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

122 %

Prated

24.00 kW

25.00 kW

SCOP

4.02

3.14

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

21.30 kW

21.70 kW

COP Tj = -7°C

2.57

1.90

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

13.00 kW

13.30 kW

COP Tj = +2°C

3.94

3.09

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

11.60 kW

11.90 kW

COP Tj = +7°C

5.03

3.96

Cdh Tj = +7 °C

0.993

0.995

Pdh Tj = 12°C

13.50 kW

14.00 kW

COP Tj = 12°C

6.96

5.51

Cdh Tj = +12 °C

0.992

0.994

Pdh Tj = Tbiv

21.30 kW

21.70 kW

COP Tj = Tbiv

2.57

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.80 kW

19.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.29

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

5.20 kW

5.50 kW

Annual energy consumption Qhe

12369 kWh

16150 kWh