Certificate holders

Subtype

Buderus Logatherm WLW196i-6 AR and IR, Buderus Logatherm WLW196i.2-4 AR

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W0128
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus Logatherm WLW196i-6 AR and IR, Buderus Logatherm WLW196i.2-4 AR
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,750 kg

Certification Date
18.07.2017
Testing basis
HP KEYMARK certification scheme rules rev. 8
Generate PDF Export model CSV
  • Number of models 16

Models

Buderus Logatherm WLW196i-6 ARE
Configure model
Model name
Buderus Logatherm WLW196i-6 ARE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.40 kW

El input

0.43 kW

0.88 kW

COP

5.27

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

261 %

175 %

Prated

6.27 kW

5.60 kW

SCOP

6.59

4.45

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.27 kW

5.60 kW

COP Tj = +2°C

3.05

2.19

Pdh Tj = +7°C

4.09 kW

3.77 kW

COP Tj = +7°C

5.70

3.86

Pdh Tj = 12°C

1.79 kW

2.54 kW

COP Tj = 12°C

8.77

5.94

Pdh Tj = Tbiv

6.27 kW

5.60 kW

COP Tj = Tbiv

3.05

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.27 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.05

2.19

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1270 kWh

1683 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

130 %

Prated

5.11 kW

4.82 kW

SCOP

4.53

3.32

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-19 °C

Pdh Tj = -7°C

3.20 kW

3.01 kW

COP Tj = -7°C

3.61

2.72

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.73

4.24

Pdh Tj = +7°C

1.19 kW

2.15 kW

COP Tj = +7°C

7.41

5.03

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

8.16

6.52

Pdh Tj = Tbiv

4.45 kW

4.20 kW

COP Tj = Tbiv

2.43

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.07 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.65

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.11 kW

4.82 kW

Annual energy consumption Qhe

2781 kWh

3575 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

1.97

COP Tj = -15°C (if TOL<-20°C)

2.68

1.97

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

143 %

Prated

5.43 kW

4.56 kW

SCOP

5.13

3.65

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.91 kW

4.26 kW

COP Tj = -7°C

3.08

2.24

Pdh Tj = +2°C

2.92 kW

2.57 kW

COP Tj = +2°C

5.00

3.66

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.99

4.68

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

8.38

6.14

Pdh Tj = Tbiv

5.43 kW

4.56 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.43 kW

4.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2190 kWh

2580 kWh

Buderus Logatherm WLW196i-6 ARB
Configure model
Model name
Buderus Logatherm WLW196i-6 ARB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.40 kW

El input

0.43 kW

0.88 kW

COP

5.27

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

261 %

175 %

Prated

6.27 kW

5.60 kW

SCOP

6.59

4.45

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.27 kW

5.60 kW

COP Tj = +2°C

3.05

2.19

Pdh Tj = +7°C

4.09 kW

3.77 kW

COP Tj = +7°C

5.70

3.86

Pdh Tj = 12°C

1.79 kW

2.54 kW

COP Tj = 12°C

8.77

5.94

Pdh Tj = Tbiv

6.27 kW

5.60 kW

COP Tj = Tbiv

3.05

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.27 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.05

2.19

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1270 kWh

1683 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

130 %

Prated

5.11 kW

4.82 kW

SCOP

4.53

3.32

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-19 °C

Pdh Tj = -7°C

3.20 kW

3.01 kW

COP Tj = -7°C

3.61

2.72

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.73

4.24

Pdh Tj = +7°C

1.19 kW

2.15 kW

COP Tj = +7°C

7.41

5.03

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

8.16

6.52

Pdh Tj = Tbiv

4.45 kW

4.20 kW

COP Tj = Tbiv

2.43

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.07 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.65

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2781 kWh

3575 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

1.97

COP Tj = -15°C (if TOL<-20°C)

2.68

1.97

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

143 %

Prated

5.43 kW

4.56 kW

SCOP

5.13

3.65

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.91 kW

4.26 kW

COP Tj = -7°C

3.08

2.24

Pdh Tj = +2°C

2.92 kW

2.57 kW

COP Tj = +2°C

5.00

3.66

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.99

4.68

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

8.38

6.14

Pdh Tj = Tbiv

5.43 kW

4.56 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.43 kW

4.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2190 kWh

2580 kWh

Buderus Logatherm WLW196i-6 ART190
Configure model
Model name
Buderus Logatherm WLW196i-6 ART190
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.40 kW

El input

0.43 kW

0.88 kW

COP

5.27

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

261 %

175 %

Prated

6.27 kW

5.60 kW

SCOP

6.59

4.45

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.27 kW

5.60 kW

COP Tj = +2°C

3.05

2.19

Pdh Tj = +7°C

4.09 kW

3.77 kW

COP Tj = +7°C

5.70

3.86

Pdh Tj = 12°C

1.79 kW

2.54 kW

COP Tj = 12°C

8.77

5.94

Pdh Tj = Tbiv

6.27 kW

5.60 kW

COP Tj = Tbiv

3.05

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.27 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.05

2.19

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1270 kWh

1683 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

130 %

Prated

5.11 kW

4.82 kW

SCOP

4.53

3.32

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-19 °C

Pdh Tj = -7°C

3.20 kW

3.01 kW

COP Tj = -7°C

3.61

2.72

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.73

4.24

Pdh Tj = +7°C

1.19 kW

2.15 kW

COP Tj = +7°C

7.41

5.03

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

8.16

6.52

Pdh Tj = Tbiv

4.45 kW

4.20 kW

COP Tj = Tbiv

2.43

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.07 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.65

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.11 kW

4.82 kW

Annual energy consumption Qhe

2781 kWh

3575 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

1.97

COP Tj = -15°C (if TOL<-20°C)

2.68

1.97

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

143 %

Prated

5.43 kW

4.56 kW

SCOP

5.13

3.65

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.91 kW

4.26 kW

COP Tj = -7°C

3.08

2.24

Pdh Tj = +2°C

2.92 kW

2.57 kW

COP Tj = +2°C

5.00

3.66

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.99

4.68

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

8.38

6.14

Pdh Tj = Tbiv

5.43 kW

4.56 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.43 kW

4.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2190 kWh

2580 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.79

Heating up time

02:31 h:min

Standby power input

45.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

271 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

97 %

COP

2.26

Heating up time

04:04 h:min

Standby power input

64.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

271 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.48

Heating up time

03:14 h:min

Standby power input

51.0 W

Reference hot water temperature

54.3 °C

Mixed water at 40°C

273 l

Buderus Logatherm WLW196i-6 ARTS185
Configure model
Model name
Buderus Logatherm WLW196i-6 ARTS185
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.40 kW

El input

0.43 kW

0.88 kW

COP

5.27

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

261 %

175 %

Prated

6.27 kW

5.60 kW

SCOP

6.59

4.45

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.27 kW

5.60 kW

COP Tj = +2°C

3.05

2.19

Pdh Tj = +7°C

4.09 kW

3.77 kW

COP Tj = +7°C

5.70

3.86

Pdh Tj = 12°C

1.79 kW

2.54 kW

COP Tj = 12°C

8.77

5.94

Pdh Tj = Tbiv

6.27 kW

5.60 kW

COP Tj = Tbiv

3.05

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.27 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.05

2.19

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1270 kWh

1683 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

130 %

Prated

5.11 kW

4.82 kW

SCOP

4.53

3.32

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-19 °C

Pdh Tj = -7°C

3.20 kW

3.01 kW

COP Tj = -7°C

3.61

2.72

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.73

4.24

Pdh Tj = +7°C

1.19 kW

2.15 kW

COP Tj = +7°C

7.41

5.03

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

8.16

6.52

Pdh Tj = Tbiv

4.45 kW

4.20 kW

COP Tj = Tbiv

2.43

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.07 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.65

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.11 kW

4.82 kW

Annual energy consumption Qhe

2781 kWh

3575 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

1.97

COP Tj = -15°C (if TOL<-20°C)

2.68

1.97

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

143 %

Prated

5.43 kW

4.56 kW

SCOP

5.13

3.65

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.91 kW

4.26 kW

COP Tj = -7°C

3.08

2.24

Pdh Tj = +2°C

2.92 kW

2.57 kW

COP Tj = +2°C

5.00

3.66

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.99

4.68

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

8.38

6.14

Pdh Tj = Tbiv

5.43 kW

4.56 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.43 kW

4.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2190 kWh

2580 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

109 %

COP

2.58

Heating up time

02:34 h:min

Standby power input

47.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

257 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

95 %

COP

2.21

Heating up time

04:09 h:min

Standby power input

73.0 W

Reference hot water temperature

51.2 °C

Mixed water at 40°C

259 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.43

Heating up time

03:18 h:min

Standby power input

53.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

263 l

Buderus Logatherm WLW196i-6 IRE
Configure model
Model name
Buderus Logatherm WLW196i-6 IRE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.34 kW

El input

0.46 kW

0.87 kW

COP

4.96

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255 %

163 %

Prated

5.77 kW

5.08 kW

SCOP

6.45

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.77 kW

5.08 kW

COP Tj = +2°C

2.91

2.09

Pdh Tj = +7°C

3.39 kW

3.55 kW

COP Tj = +7°C

5.70

3.62

Pdh Tj = 12°C

1.79 kW

2.42 kW

COP Tj = 12°C

8.45

5.56

Pdh Tj = Tbiv

5.77 kW

5.08 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.77 kW

5.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.91

2.09

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1195 kWh

1631 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

128 %

Prated

5.27 kW

4.82 kW

SCOP

4.27

3.28

Tbiv

-16 °C

-15 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

3.20 kW

2.91 kW

COP Tj = -7°C

3.17

2.72

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.73

4.24

Pdh Tj = +7°C

1.14 kW

2.15 kW

COP Tj = +7°C

7.41

5.03

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

8.16

6.52

Pdh Tj = Tbiv

4.45 kW

3.89 kW

COP Tj = Tbiv

2.43

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.50 kW

3.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.07

1.64

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.27 kW

4.82 kW

Annual energy consumption Qhe

3040 kWh

3621 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

1.97

COP Tj = -15°C (if TOL<-20°C)

2.44

1.97

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

140 %

Prated

5.18 kW

4.20 kW

SCOP

4.68

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.67 kW

3.86 kW

COP Tj = -7°C

2.95

2.24

Pdh Tj = +2°C

2.81 kW

2.38 kW

COP Tj = +2°C

4.26

3.66

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.99

4.43

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

8.06

5.56

Pdh Tj = Tbiv

5.18 kW

4.20 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.18 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2289 kWh

2431 kWh

Buderus Logatherm WLW196i-6 IRB
Configure model
Model name
Buderus Logatherm WLW196i-6 IRB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.34 kW

El input

0.46 kW

0.87 kW

COP

4.96

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255 %

163 %

Prated

5.77 kW

5.08 kW

SCOP

6.45

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.77 kW

5.08 kW

COP Tj = +2°C

2.91

2.09

Pdh Tj = +7°C

3.39 kW

3.55 kW

COP Tj = +7°C

5.70

3.62

Pdh Tj = 12°C

1.79 kW

2.42 kW

COP Tj = 12°C

8.45

5.56

Pdh Tj = Tbiv

5.77 kW

5.08 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.77 kW

5.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.91

2.09

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1195 kWh

1631 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

128 %

Prated

5.27 kW

4.82 kW

SCOP

4.27

3.28

Tbiv

-16 °C

-15 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

3.20 kW

2.91 kW

COP Tj = -7°C

3.17

2.72

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.73

4.24

Pdh Tj = +7°C

1.14 kW

2.15 kW

COP Tj = +7°C

7.41

5.03

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

8.16

6.52

Pdh Tj = Tbiv

4.45 kW

3.89 kW

COP Tj = Tbiv

2.43

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.50 kW

3.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.07

1.64

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3040 kWh

3621 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

1.97

COP Tj = -15°C (if TOL<-20°C)

2.44

1.97

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

140 %

Prated

5.18 kW

4.20 kW

SCOP

4.68

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.67 kW

3.86 kW

COP Tj = -7°C

2.95

2.24

Pdh Tj = +2°C

2.81 kW

2.38 kW

COP Tj = +2°C

4.26

3.66

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.99

4.43

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

8.06

5.56

Pdh Tj = Tbiv

5.18 kW

4.20 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.18 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2289 kWh

2431 kWh

Buderus Logatherm WLW196i-6 IRT190
Configure model
Model name
Buderus Logatherm WLW196i-6 IRT190
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.34 kW

El input

0.46 kW

0.87 kW

COP

4.96

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255 %

163 %

Prated

5.77 kW

5.08 kW

SCOP

6.45

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.77 kW

5.08 kW

COP Tj = +2°C

2.91

2.09

Pdh Tj = +7°C

3.39 kW

3.55 kW

COP Tj = +7°C

5.70

3.62

Pdh Tj = 12°C

1.79 kW

2.42 kW

COP Tj = 12°C

8.45

5.56

Pdh Tj = Tbiv

5.77 kW

5.08 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.77 kW

5.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.91

2.09

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1195 kWh

1631 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

128 %

Prated

5.27 kW

4.82 kW

SCOP

4.27

3.28

Tbiv

-16 °C

-15 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

3.20 kW

2.91 kW

COP Tj = -7°C

3.17

2.72

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.73

4.24

Pdh Tj = +7°C

1.14 kW

2.15 kW

COP Tj = +7°C

7.41

5.03

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

8.16

6.52

Pdh Tj = Tbiv

4.45 kW

3.89 kW

COP Tj = Tbiv

2.43

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.50 kW

3.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.07

1.64

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.27 kW

4.82 kW

Annual energy consumption Qhe

3040 kWh

3621 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

1.97

COP Tj = -15°C (if TOL<-20°C)

2.44

1.97

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

140 %

Prated

5.18 kW

4.20 kW

SCOP

4.68

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.67 kW

3.86 kW

COP Tj = -7°C

2.95

2.24

Pdh Tj = +2°C

2.81 kW

2.38 kW

COP Tj = +2°C

4.26

3.66

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.99

4.43

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

8.06

5.56

Pdh Tj = Tbiv

5.18 kW

4.20 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.18 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2289 kWh

2431 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.80

Heating up time

02:31 h:min

Standby power input

45.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

271 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

97 %

COP

2.26

Heating up time

04:04 h:min

Standby power input

64.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

271 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.48

Heating up time

03:14 h:min

Standby power input

51.0 W

Reference hot water temperature

54.3 °C

Mixed water at 40°C

273 l

Buderus Logatherm WLW196i-6 IRTS185
Configure model
Model name
Buderus Logatherm WLW196i-6 IRTS185
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.34 kW

El input

0.46 kW

0.87 kW

COP

4.96

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255 %

163 %

Prated

5.77 kW

5.08 kW

SCOP

6.45

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.77 kW

5.08 kW

COP Tj = +2°C

2.91

2.09

Pdh Tj = +7°C

3.39 kW

3.55 kW

COP Tj = +7°C

5.70

3.62

Pdh Tj = 12°C

1.79 kW

2.42 kW

COP Tj = 12°C

8.45

5.56

Pdh Tj = Tbiv

5.77 kW

5.08 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.77 kW

5.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.91

2.09

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1195 kWh

1631 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

128 %

Prated

5.27 kW

4.82 kW

SCOP

4.27

3.28

Tbiv

-16 °C

-15 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

3.20 kW

2.91 kW

COP Tj = -7°C

3.17

2.72

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.73

4.24

Pdh Tj = +7°C

1.14 kW

2.15 kW

COP Tj = +7°C

7.41

5.03

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

8.16

6.52

Pdh Tj = Tbiv

4.45 kW

3.89 kW

COP Tj = Tbiv

2.43

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.50 kW

3.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.07

1.64

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.27 kW

4.82 kW

Annual energy consumption Qhe

3040 kWh

3621 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

1.97

COP Tj = -15°C (if TOL<-20°C)

2.44

1.97

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

140 %

Prated

5.18 kW

4.20 kW

SCOP

4.68

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.67 kW

3.86 kW

COP Tj = -7°C

2.95

2.24

Pdh Tj = +2°C

2.81 kW

2.38 kW

COP Tj = +2°C

4.26

3.66

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.99

4.43

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

8.06

5.56

Pdh Tj = Tbiv

5.18 kW

4.20 kW

COP Tj = Tbiv

2.64

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.18 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2289 kWh

2431 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

109 %

COP

2.58

Heating up time

02:34 h:min

Standby power input

47.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

257 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

95 %

COP

2.21

Heating up time

04:09 h:min

Standby power input

73.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

259 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.43

Heating up time

03:18 h:min

Standby power input

53.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

263 l

Buderus Logatherm WLW196i.2-4 ARB S+
Configure model
Model name
Buderus Logatherm WLW196i.2-4 ARB S+
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.82 kW

1.78 kW

El input

0.56 kW

0.69 kW

COP

5.01

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

163 %

Prated

5.50 kW

5.40 kW

SCOP

6.07

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.48 kW

5.40 kW

COP Tj = +2°C

3.03

2.10

Pdh Tj = +7°C

3.81 kW

3.56 kW

COP Tj = +7°C

5.16

3.57

Pdh Tj = 12°C

1.71 kW

2.44 kW

COP Tj = 12°C

8.06

5.53

Pdh Tj = Tbiv

5.48 kW

5.40 kW

COP Tj = Tbiv

3.03

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.48 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.03

2.10

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1211 kWh

1736 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

118 %

Prated

4.30 kW

4.00 kW

SCOP

4.27

3.03

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.50 kW

2.29 kW

COP Tj = -7°C

3.64

2.52

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

1.49 kW

1.80 kW

COP Tj = +2°C

5.22

3.82

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.14 kW

2.08 kW

COP Tj = +7°C

6.44

4.68

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.24 kW

2.48 kW

COP Tj = 12°C

7.03

6.02

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

3.75 kW

3.53 kW

COP Tj = Tbiv

2.29

1.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.44 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.56

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2482 kWh

3252 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

133 %

Prated

4.76 kW

4.49 kW

SCOP

4.98

3.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.27 kW

3.93 kW

COP Tj = -7°C

3.11

2.11

Pdh Tj = +2°C

2.51 kW

2.41 kW

COP Tj = +2°C

4.96

3.36

Pdh Tj = +7°C

1.51 kW

2.06 kW

COP Tj = +7°C

6.40

4.41

Pdh Tj = 12°C

1.27 kW

2.45 kW

COP Tj = 12°C

7.53

5.76

Pdh Tj = Tbiv

4.76 kW

4.49 kW

COP Tj = Tbiv

2.68

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.76 kW

4.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.82

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1975 kWh

2724 kWh

Buderus Logatherm WLW196i.2-4 ARE S+
Configure model
Model name
Buderus Logatherm WLW196i.2-4 ARE S+
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.82 kW

1.78 kW

El input

0.56 kW

0.69 kW

COP

5.01

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

163 %

Prated

5.50 kW

5.40 kW

SCOP

6.07

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.48 kW

5.40 kW

COP Tj = +2°C

3.03

2.10

Pdh Tj = +7°C

3.81 kW

3.56 kW

COP Tj = +7°C

5.16

3.57

Pdh Tj = 12°C

1.71 kW

2.44 kW

COP Tj = 12°C

8.06

5.53

Pdh Tj = Tbiv

5.48 kW

5.40 kW

COP Tj = Tbiv

3.03

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.48 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.03

2.10

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1211 kWh

1736 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

118 %

Prated

4.30 kW

4.00 kW

SCOP

4.27

3.03

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.50 kW

2.29 kW

COP Tj = -7°C

3.64

2.52

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

1.49 kW

1.80 kW

COP Tj = +2°C

5.22

3.82

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.14 kW

2.08 kW

COP Tj = +7°C

6.44

4.68

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.24 kW

2.48 kW

COP Tj = 12°C

7.03

6.02

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

3.75 kW

3.53 kW

COP Tj = Tbiv

2.29

1.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.44 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.56

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.30 kW

4.00 kW

Annual energy consumption Qhe

2482 kWh

3252 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.75

3.53

COP Tj = -15°C (if TOL<-20°C)

2.29

1.64

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

133 %

Prated

4.76 kW

4.49 kW

SCOP

4.98

3.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.27 kW

3.93 kW

COP Tj = -7°C

3.11

2.11

Pdh Tj = +2°C

2.51 kW

2.41 kW

COP Tj = +2°C

4.96

3.36

Pdh Tj = +7°C

1.51 kW

2.06 kW

COP Tj = +7°C

6.40

4.41

Pdh Tj = 12°C

1.27 kW

2.45 kW

COP Tj = 12°C

7.53

5.76

Pdh Tj = Tbiv

4.76 kW

4.49 kW

COP Tj = Tbiv

2.68

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.76 kW

4.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.82

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1975 kWh

2724 kWh

Buderus Logatherm WLW196i.2-4 ART190 S+
Configure model
Model name
Buderus Logatherm WLW196i.2-4 ART190 S+
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.82 kW

1.78 kW

El input

0.56 kW

0.69 kW

COP

5.01

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

163 %

Prated

5.50 kW

5.40 kW

SCOP

6.07

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.48 kW

5.40 kW

COP Tj = +2°C

3.03

2.10

Pdh Tj = +7°C

3.81 kW

3.56 kW

COP Tj = +7°C

5.16

3.57

Pdh Tj = 12°C

1.71 kW

2.44 kW

COP Tj = 12°C

8.06

5.53

Pdh Tj = Tbiv

5.48 kW

5.40 kW

COP Tj = Tbiv

3.03

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.48 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.03

2.10

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1211 kWh

1736 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

118 %

Prated

4.30 kW

4.00 kW

SCOP

4.27

3.03

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.50 kW

2.29 kW

COP Tj = -7°C

3.64

2.52

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

1.49 kW

1.80 kW

COP Tj = +2°C

5.22

3.82

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.14 kW

2.08 kW

COP Tj = +7°C

6.44

4.68

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.24 kW

2.48 kW

COP Tj = 12°C

7.03

6.02

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

3.75 kW

3.53 kW

COP Tj = Tbiv

2.29

1.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.44 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.56

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.30 kW

4.00 kW

Annual energy consumption Qhe

2482 kWh

3252 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.75

1.64

COP Tj = -15°C (if TOL<-20°C)

2.29

1.64

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

133 %

Prated

4.76 kW

4.49 kW

SCOP

4.98

3.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.27 kW

3.93 kW

COP Tj = -7°C

3.11

2.11

Pdh Tj = +2°C

2.51 kW

2.41 kW

COP Tj = +2°C

4.96

3.36

Pdh Tj = +7°C

1.51 kW

2.06 kW

COP Tj = +7°C

6.40

4.41

Pdh Tj = 12°C

1.27 kW

2.45 kW

COP Tj = 12°C

7.53

5.76

Pdh Tj = Tbiv

4.76 kW

4.49 kW

COP Tj = Tbiv

2.68

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.76 kW

4.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.82

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1975 kWh

2724 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

119 %

COP

2.80

Heating up time

02:49 h:min

Standby power input

47.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

261 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

84 %

COP

1.96

Heating up time

04:11 h:min

Standby power input

66.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

279 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.36

Heating up time

03:34 h:min

Standby power input

52.0 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

271 l

Buderus Logatherm WLW196i.2-4 ARTS185 S+
Configure model
Model name
Buderus Logatherm WLW196i.2-4 ARTS185 S+
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.82 kW

1.78 kW

El input

0.56 kW

0.69 kW

COP

5.01

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

163 %

Prated

5.50 kW

5.40 kW

SCOP

6.07

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.48 kW

5.40 kW

COP Tj = +2°C

3.03

2.10

Pdh Tj = +7°C

3.81 kW

3.56 kW

COP Tj = +7°C

5.16

3.57

Pdh Tj = 12°C

1.71 kW

2.44 kW

COP Tj = 12°C

8.06

5.53

Pdh Tj = Tbiv

5.48 kW

5.40 kW

COP Tj = Tbiv

3.03

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.48 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.03

2.10

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1211 kWh

1736 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

118 %

Prated

4.30 kW

4.00 kW

SCOP

4.27

3.03

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.50 kW

2.29 kW

COP Tj = -7°C

3.64

2.52

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

1.49 kW

1.80 kW

COP Tj = +2°C

5.22

3.82

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.14 kW

2.08 kW

COP Tj = +7°C

6.44

4.68

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.24 kW

2.48 kW

COP Tj = 12°C

7.03

6.02

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

3.75 kW

3.53 kW

COP Tj = Tbiv

2.29

1.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.44 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.56

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.30 kW

4.00 kW

Annual energy consumption Qhe

2482 kWh

3252 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.75

1.64

COP Tj = -15°C (if TOL<-20°C)

2.29

1.64

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

133 %

Prated

4.76 kW

4.49 kW

SCOP

4.98

3.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.27 kW

3.93 kW

COP Tj = -7°C

3.11

2.11

Pdh Tj = +2°C

2.51 kW

2.41 kW

COP Tj = +2°C

4.96

3.36

Pdh Tj = +7°C

1.51 kW

2.06 kW

COP Tj = +7°C

6.40

4.41

Pdh Tj = 12°C

1.27 kW

2.45 kW

COP Tj = 12°C

7.53

5.76

Pdh Tj = Tbiv

4.76 kW

4.49 kW

COP Tj = Tbiv

2.68

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.76 kW

4.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.82

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1975 kWh

2724 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.58

Heating up time

02:45 h:min

Standby power input

49.0 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

247 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

80 %

COP

1.88

Heating up time

04:05 h:min

Standby power input

67.0 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

259 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98 %

COP

2.31

Heating up time

03:12 h:min

Standby power input

54.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

261 l

Buderus Hybrid-Set WLW196i-6 A H
Configure model
Model name
Buderus Hybrid-Set WLW196i-6 A H
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.03 kW

7.41 kW

El input

2.4 kW

2.82 kW

COP

3.76

2.62

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

164 %

Prated

6.54 kW

6.10 kW

SCOP

5.31

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.54 kW

6.1 kW

COP Tj = +2°C

3.04

2.33

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.02 kW

4.07 kW

COP Tj = +7°C

5.03

3.47

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

1.77 kW

2.49 kW

COP Tj = 12°C

6.36

5.71

Cdh Tj = +12 °C

1.000

0.950

Pdh Tj = Tbiv

6.54 kW

6.1 kW

COP Tj = Tbiv

3.04

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.54 kW

6.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.33

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

6 W

6 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1645 kWh

1957 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

122 %

Prated

5.35 kW

5.29 kW

SCOP

3.87

3.13

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-19 °C

Pdh Tj = -7°C

3.19 kW

3.21 kW

COP Tj = -7°C

3.32

2.52

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

1.18 kW

1.78 kW

COP Tj = +2°C

4.59

3.71

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.18 kW

2.13 kW

COP Tj = +7°C

5.00

5.01

Cdh Tj = +7 °C

1.000

0.950

Pdh Tj = 12°C

1.36 kW

2.58 kW

COP Tj = 12°C

6.19

6.89

Cdh Tj = +12 °C

0.900

0.940

Pdh Tj = Tbiv

4.39 kW

4.32 kW

COP Tj = Tbiv

2.31

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.07 kW

1.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.54

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

6 W

6 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

1.28 kW

3.52 kW

Annual energy consumption Qhe

3405 kWh

4162 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

133 %

Prated

5.39 kW

6.25 kW

SCOP

4.31

3.4

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.55 kW

5.53 kW

COP Tj = -7°C

2.96

2.02

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.63 kW

3.53 kW

COP Tj = +2°C

4.34

3.31

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.75 kW

2.13 kW

COP Tj = +7°C

5.24

4.55

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

1.36 kW

2.54 kW

COP Tj = 12°C

6.25

6.41

Cdh Tj = +12 °C

0.900

0.940

Pdh Tj = Tbiv

5.39 kW

5.53 kW

COP Tj = Tbiv

2.56

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.39 kW

4.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.93

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

6 W

6 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

0 kW

1.6 kW

Annual energy consumption Qhe

2586 kWh

3800 kWh

Buderus Logatherm WLW196i-6 IRTP120
Configure model
Model name
Buderus Logatherm WLW196i-6 IRTP120
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.29 kW

2.34 kW

El input

0.49 kW

0.90 kW

COP

4.69

2.59

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

156 %

Prated

5.77 kW

5.08 kW

SCOP

6.00

3.98

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.77 kW

5.08 kW

COP Tj = +2°C

2.83

2.06

Pdh Tj = +7°C

3.39 kW

3.55 kW

COP Tj = +7°C

5.39

3.53

Pdh Tj = 12°C

1.79 kW

2.42 kW

COP Tj = 12°C

7.60

5.29

Pdh Tj = Tbiv

5.77 kW

5.08 kW

COP Tj = Tbiv

2.83

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.77 kW

5.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.06

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1285 kWh

1704 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

122 %

Prated

5.27 kW

4.82 kW

SCOP

4.03

3.14

Tbiv

-16 °C

-16 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.20 kW

2.91 kW

COP Tj = -7°C

3.07

2.66

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.33

4.05

Pdh Tj = +7°C

1.14 kW

2.15 kW

COP Tj = +7°C

6.53

4.79

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

7.20

6.16

Pdh Tj = Tbiv

4.45 kW

3.93 kW

COP Tj = Tbiv

2.38

1.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.50 kW

3.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.03

1.62

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.27 kW

4.82 kW

Annual energy consumption Qhe

3222 kWh

3787 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

3.89

COP Tj = -15°C (if TOL<-20°C)

2.38

1.94

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

134 %

Prated

5.17 kW

4.20 kW

SCOP

4.41

3.44

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.67 kW

3.86 kW

COP Tj = -7°C

2.87

2.21

Pdh Tj = +2°C

2.81 kW

2.38 kW

COP Tj = +2°C

5.33

3.56

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.40

4.26

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

7.13

5.35

Pdh Tj = Tbiv

5.18 kW

4.20 kW

COP Tj = Tbiv

2.58

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.18 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.88

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2421 kWh

2525 kWh

Buderus Logatherm WLW196i-6 ARTP120
Configure model
Model name
Buderus Logatherm WLW196i-6 ARTP120
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.28 kW

2.40 kW

El input

0.46 kW

0.90 kW

COP

4.96

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

241 %

167 %

Prated

6.27 kW

5.60 kW

SCOP

6.11

4.25

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.27 kW

5.60 kW

COP Tj = +2°C

2.95

2.16

Pdh Tj = +7°C

4.09 kW

3.77 kW

COP Tj = +7°C

5.41

3.76

Pdh Tj = 12°C

1.79 kW

2.54 kW

COP Tj = 12°C

7.85

5.64

Pdh Tj = Tbiv

6.27 kW

5.60 kW

COP Tj = Tbiv

2.95

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.27 kW

5.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.95

2.16

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1371 kWh

1762 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

125 %

Prated

5.11 kW

4.82 kW

SCOP

4.26

3.20

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-19 °C

Pdh Tj = -7°C

3.20 kW

3.01 kW

COP Tj = -7°C

3.49

2.66

Pdh Tj = +2°C

1.80 kW

1.91 kW

COP Tj = +2°C

5.32

4.05

Pdh Tj = +7°C

1.19 kW

2.15 kW

COP Tj = +7°C

6.54

4.78

Pdh Tj = 12°C

1.31 kW

2.61 kW

COP Tj = 12°C

7.19

6.16

Pdh Tj = Tbiv

4.45 kW

4.20 kW

COP Tj = Tbiv

2.38

1.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.07 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

1.62

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.11 kW

4.82 kW

Annual energy consumption Qhe

2956 kWh

3715 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.15

3.89

COP Tj = -15°C (if TOL<-20°C)

2.62

1.94

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

137 %

Prated

5.43 kW

4.56 kW

SCOP

4.81

3.50

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.90 kW

4.26 kW

COP Tj = -7°C

2.99

2.21

Pdh Tj = +2°C

2.92 kW

2.57 kW

COP Tj = +2°C

4.74

3.55

Pdh Tj = +7°C

1.84 kW

2.11 kW

COP Tj = +7°C

6.41

4.47

Pdh Tj = 12°C

1.33 kW

2.56 kW

COP Tj = 12°C

7.37

5.82

Pdh Tj = Tbiv

5.43 kW

4.56 kW

COP Tj = Tbiv

2.58

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.43 kW

4.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.87

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

4 W

4 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2335 kWh

2689 kWh

Buderus Logatherm WLW196i.2-4 ARTP120 S+
Configure model
Model name
Buderus Logatherm WLW196i.2-4 ARTP120 S+
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.82 kW

1.78 kW

El input

0.59 kW

0.71 kW

COP

4.76

2.49

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

223 %

158 %

Prated

5.50 kW

5.40 kW

SCOP

5.65

4.01

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.48 kW

5.40 kW

COP Tj = +2°C

2.93

2.07

Pdh Tj = +7°C

3.81 kW

3.56 kW

COP Tj = +7°C

4.91

3.48

Pdh Tj = 12°C

1.71 kW

2.44 kW

COP Tj = 12°C

7.26

5.26

Pdh Tj = Tbiv

5.48 kW

5.40 kW

COP Tj = Tbiv

2.93

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.48 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

2.07

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1301 kWh

1797 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

113 %

Prated

4.30 kW

4.00 kW

SCOP

4.00

2.90

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

2.50 kW

2.29 kW

COP Tj = -7°C

3.50

2.46

Pdh Tj = +2°C

1.49 kW

1.80 kW

COP Tj = +2°C

4.84

3.65

Pdh Tj = +7°C

1.14 kW

2.08 kW

COP Tj = +7°C

5.73

4.46

Pdh Tj = 12°C

1.24 kW

2.48 kW

COP Tj = 12°C

6.26

5.71

Pdh Tj = Tbiv

3.75 kW

3.53 kW

COP Tj = Tbiv

2.24

1.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.44 kW

3.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.07

1.54

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.30 kW

4.00 kW

Annual energy consumption Qhe

2650 kWh

3405 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.75

3.53

COP Tj = -15°C (if TOL<-20°C)

2.24

1.62

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

127 %

Prated

4.76 kW

4.49 kW

SCOP

4.66

3.26

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.27 kW

3.94 kW

COP Tj = -7°C

3.02

2.08

Pdh Tj = +2°C

2.51 kW

2.41 kW

COP Tj = +2°C

4.70

3.26

Pdh Tj = +7°C

1.51 kW

2.06 kW

COP Tj = +7°C

5.85

4.21

Pdh Tj = 12°C

1.27 kW

2.45 kW

COP Tj = 12°C

6.67

5.47

Pdh Tj = Tbiv

4.76 kW

4.49 kW

COP Tj = Tbiv

2.62

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.76 kW

4.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.80

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

22 W

22 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2112 kWh

2843 kWh