1,630 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.50 kW
9.00 kW
El input
2.10 kW
3.33 kW
COP
4.50
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
130 %
Prated
8.50 kW
8.20 kW
SCOP
4.53
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.50 kW
7.30 kW
COP Tj = -7°C
2.98
2.05
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.60 kW
4.40 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.90 kW
3.50 kW
COP Tj = +7°C
5.89
4.60
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
4.40 kW
4.30 kW
COP Tj = 12°C
7.14
5.97
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.50 kW
7.30 kW
COP Tj = Tbiv
2.98
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.30 kW
7.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
4 W
4 W
PTO
20 W
21 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.20 kW
1.10 kW
Annual energy consumption Qhe
3875 kWh
5083 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.50 kW
9.00 kW
El input
2.10 kW
3.33 kW
COP
4.50
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
130 %
Prated
8.50 kW
8.20 kW
SCOP
4.53
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.50 kW
7.30 kW
COP Tj = -7°C
2.98
2.05
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.60 kW
4.40 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.90 kW
3.50 kW
COP Tj = +7°C
5.89
4.60
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
4.40 kW
4.30 kW
COP Tj = 12°C
7.14
5.97
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
7.50 kW
7.30 kW
COP Tj = Tbiv
2.98
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.30 kW
7.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
4 W
4 W
PTO
20 W
21 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.20 kW
1.10 kW
Annual energy consumption Qhe
3875 kWh
5083 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.10
Heating up time
1:15 h:min
Standby power input
35.0 W
Reference hot water temperature
54.0 °C
Mixed water at 40°C
245 l