Certificate holders

Subtype

16. Yutaki S80 5.0HP (tri)

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-16
Certification Body
BRE Global Limited
Subtype title
16. Yutaki S80 5.0HP (tri)
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,400 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

RAS-5WHNPE RWH-5.0NFE - Type 1
Configure model
Model name
RAS-5WHNPE RWH-5.0NFE - Type 1
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.97 kW

4.39 kW

COP

4.71

3.19

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

57 dB(A)

57 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

171 %

129 %

Prated

14.00 kW

14.00 kW

SCOP

4.35

3.30

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

12.38 kW

COP Tj = -7°C

2.55

2.19

Pdh Tj = +2°C

7.30 kW

7.54 kW

COP Tj = +2°C

4.70

3.10

Pdh Tj = +7°C

4.70 kW

4.85 kW

COP Tj = +7°C

5.70

4.60

Pdh Tj = 12°C

3.50 kW

4.10 kW

COP Tj = 12°C

6.00

6.40

Pdh Tj = Tbiv

12.00 kW

14.00 kW

COP Tj = Tbiv

2.55

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.10 kW

14.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

44 W

44 W

PTO

0 W

0 W

PSB

44 W

44 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.90 kW

0.00 kW

Annual energy consumption Qhe

6426 kWh

8747 kWh

RAS-5WHNPE RWH-5.0NFWE - Type 2
Configure model
Model name
RAS-5WHNPE RWH-5.0NFWE - Type 2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.97 kW

4.39 kW

COP

4.71

3.19

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

57 dB(A)

57 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

171 %

129 %

Prated

14.00 kW

14.00 kW

SCOP

4.35

3.30

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

12.38 kW

COP Tj = -7°C

2.55

2.19

Pdh Tj = +2°C

7.30 kW

7.54 kW

COP Tj = +2°C

4.70

3.10

Pdh Tj = +7°C

4.70 kW

4.85 kW

COP Tj = +7°C

5.70

4.60

Pdh Tj = 12°C

3.50 kW

4.10 kW

COP Tj = 12°C

6.00

6.40

Pdh Tj = Tbiv

12.00 kW

14.00 kW

COP Tj = Tbiv

2.55

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.10 kW

14.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

44 W

44 W

PTO

0 W

0 W

PSB

44 W

44 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.90 kW

0.00 kW

Annual energy consumption Qhe

6426 kWh

8747 kWh