Certificate holders

Subtype

15. Yutaki S80 4.0HP (tri)

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-15
Certification Body
BRE Global Limited
Subtype title
15. Yutaki S80 4.0HP (tri)
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,300 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

RAS-4WHNPE RWH-4.0NFE - Type 1
Configure model
Model name
RAS-4WHNPE RWH-4.0NFE - Type 1
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

11.00 kW

11.00 kW

El input

2.20 kW

3.31 kW

COP

5.00

3.32

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

57 dB(A)

57 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

140 %

Prated

11.00 kW

11.00 kW

SCOP

4.65

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.60 kW

9.73 kW

COP Tj = -7°C

2.74

2.30

Pdh Tj = +2°C

5.84 kW

5.92 kW

COP Tj = +2°C

5.20

3.60

Pdh Tj = +7°C

3.76 kW

3.81 kW

COP Tj = +7°C

5.80

4.70

Pdh Tj = 12°C

3.70 kW

3.60 kW

COP Tj = 12°C

6.40

6.00

Pdh Tj = Tbiv

9.60 kW

11.00 kW

COP Tj = Tbiv

2.74

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.50 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

44 W

44 W

PTO

0 W

0 W

PSB

44 W

44 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

0.00 kW

Annual energy consumption Qhe

4828 kWh

6360 kWh

RAS-4WHNPE RWH-4.0NFWE - Type 2
Configure model
Model name
RAS-4WHNPE RWH-4.0NFWE - Type 2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

11.00 kW

11.00 kW

El input

2.20 kW

3.31 kW

COP

5.00

3.32

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

57 dB(A)

57 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

140 %

Prated

11.00 kW

11.00 kW

SCOP

4.65

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.60 kW

9.73 kW

COP Tj = -7°C

2.74

2.30

Pdh Tj = +2°C

5.84 kW

5.92 kW

COP Tj = +2°C

5.20

3.60

Pdh Tj = +7°C

3.76 kW

3.81 kW

COP Tj = +7°C

5.80

4.70

Pdh Tj = 12°C

3.70 kW

3.60 kW

COP Tj = 12°C

6.40

6.00

Pdh Tj = Tbiv

9.60 kW

11.00 kW

COP Tj = Tbiv

2.74

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.50 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

44 W

44 W

PTO

0 W

0 W

PSB

44 W

44 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

0.00 kW

Annual energy consumption Qhe

4828 kWh

6360 kWh