Certificate holders

Subtype

HMI140 / DHWT300

Certificate Holder
AERMEC S.p.A.
Via Roma 996
37040 Bevilacqua (VR)
Italy
Registration number
041-K011-06
Certification Body
BRE Global Limited
Subtype title
HMI140 / DHWT300
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,200 kg

Certification Date
25.03.2021
Testing basis
Heat Pump Keymark Scheme Rules Rev 08
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

HMI140 / DHWT300X
Configure model
Model name
HMI140 / DHWT300X
Application
Heating + DHW
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

13.50 kW

El input

5.19 kW

COP

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level outdoor

70 dB(A)

EN 14825

Medium temperature

ηs

127 %

Prated

11.00 kW

SCOP

3.25

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

10.34 kW

COP Tj = -7°C

2.13

Cdh Tj = -7 °C

0.98

Pdh Tj = +2°C

6.00 kW

COP Tj = +2°C

3.15

Cdh Tj = +2 °C

0.98

Pdh Tj = +7°C

5.76 kW

COP Tj = +7°C

4.24

Cdh Tj = +7 °C

0.98

Pdh Tj = 12°C

6.36 kW

COP Tj = 12°C

5.06

Cdh Tj = +12 °C

0.98

Pdh Tj = Tbiv

10.34 kW

COP Tj = Tbiv

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.78

WTOL

55 °C

Poff

18 W

PTO

18 W

PSB

18 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.59 kW

Annual energy consumption Qhe

6993 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:52 h:min

Standby power input

62.6 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

372 l

HMI140T / DHWT300XT
Configure model
Model name
HMI140T / DHWT300XT
Application
Heating + DHW
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

13.50 kW

El input

5.19 kW

COP

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level outdoor

70 dB(A)

EN 14825

Medium temperature

ηs

127 %

Prated

11.00 kW

SCOP

3.25

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

10.34 kW

COP Tj = -7°C

2.13

Cdh Tj = -7 °C

0.98

Pdh Tj = +2°C

6.00 kW

COP Tj = +2°C

3.15

Cdh Tj = +2 °C

0.98

Pdh Tj = +7°C

5.76 kW

COP Tj = +7°C

4.24

Cdh Tj = +7 °C

0.98

Pdh Tj = 12°C

6.36 kW

COP Tj = 12°C

5.06

Cdh Tj = +12 °C

0.98

Pdh Tj = Tbiv

10.34 kW

COP Tj = Tbiv

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.78

WTOL

55 °C

Poff

18 W

PTO

18 W

PSB

18 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.59 kW

Annual energy consumption Qhe

6993 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:52 h:min

Standby power input

62.6 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

372 l