Certificate holders

Subtype

Buderus Logatherm WLW196i-8 AR and IR, Buderus Logatherm WLW196i.2-6 AR

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W0129
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus Logatherm WLW196i-8 AR and IR, Buderus Logatherm WLW196i.2-6 AR
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,350 kg

Certification Date
18.07.2017
Testing basis
HP KEYMARK certification scheme rules rev. 8
Generate PDF Export model CSV
  • Number of models 17

Models

Buderus Logatherm WLW196i-8 ARE
Configure model
Model name
Buderus Logatherm WLW196i-8 ARE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.77 kW

2.41 kW

El input

0.75 kW

0.91 kW

COP

5.02

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

178 %

Prated

9.00 kW

7.90 kW

SCOP

6.25

4.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.02 kW

7.93 kW

COP Tj = +2°C

2.96

2.28

Pdh Tj = +7°C

6.08 kW

4.95 kW

COP Tj = +7°C

5.37

3.95

Pdh Tj = 12°C

2.61 kW

3.33 kW

COP Tj = 12°C

8.27

5.89

Pdh Tj = Tbiv

9.02 kW

7.93 kW

COP Tj = Tbiv

2.96

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.02 kW

7.93 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.96

2.28

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1924 kWh

2332 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

126 %

Prated

6.10 kW

6.00 kW

SCOP

4.49

3.22

Tbiv

-20 °C

-18 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

3.44 kW

3.61 kW

COP Tj = -7°C

3.87

2.77

Pdh Tj = +2°C

2.27 kW

2.43 kW

COP Tj = +2°C

5.43

3.89

Pdh Tj = +7°C

1.59 kW

2.79 kW

COP Tj = +7°C

5.75

4.70

Pdh Tj = 12°C

1.69 kW

3.23 kW

COP Tj = 12°C

7.40

5.84

Pdh Tj = Tbiv

5.84 kW

5.38 kW

COP Tj = Tbiv

2.36

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

5.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.87

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.10 kW

6.00 kW

Annual energy consumption Qhe

3346 kWh

4594 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.93

2.06

COP Tj = -15°C (if TOL<-20°C)

2.87

2.06

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

145 %

Prated

7.60 kW

6.50 kW

SCOP

4.93

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.75 kW

5.71 kW

COP Tj = -7°C

3.16

2.32

Pdh Tj = +2°C

4.09 kW

3.35 kW

COP Tj = +2°C

4.92

3.67

Pdh Tj = +7°C

2.51 kW

2.76 kW

COP Tj = +7°C

6.05

4.65

Pdh Tj = 12°C

1.66 kW

3.40 kW

COP Tj = 12°C

7.59

6.19

Pdh Tj = Tbiv

7.65 kW

6.50 kW

COP Tj = Tbiv

2.67

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.65 kW

6.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3188 kWh

3631 kWh

Buderus Logatherm WLW196i-8 ARB
Configure model
Model name
Buderus Logatherm WLW196i-8 ARB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.77 kW

2.41 kW

El input

0.75 kW

0.91 kW

COP

5.02

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

178 %

Prated

9.00 kW

7.90 kW

SCOP

6.25

4.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.02 kW

7.93 kW

COP Tj = +2°C

2.96

2.28

Pdh Tj = +7°C

6.08 kW

4.95 kW

COP Tj = +7°C

5.37

3.95

Pdh Tj = 12°C

2.61 kW

3.33 kW

COP Tj = 12°C

8.27

5.89

Pdh Tj = Tbiv

9.02 kW

7.93 kW

COP Tj = Tbiv

2.96

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.02 kW

7.93 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.96

2.28

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1924 kWh

2332 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

126 %

Prated

6.10 kW

6.00 kW

SCOP

4.49

3.22

Tbiv

-20 °C

-18 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

3.44 kW

3.61 kW

COP Tj = -7°C

3.87

2.77

Pdh Tj = +2°C

2.27 kW

2.43 kW

COP Tj = +2°C

5.43

3.89

Pdh Tj = +7°C

1.59 kW

2.79 kW

COP Tj = +7°C

5.75

4.70

Pdh Tj = 12°C

1.69 kW

3.23 kW

COP Tj = 12°C

7.40

5.84

Pdh Tj = Tbiv

5.84 kW

5.38 kW

COP Tj = Tbiv

2.36

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

5.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.87

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3346 kWh

4594 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.93

2.06

COP Tj = -15°C (if TOL<-20°C)

2.87

2.06

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

145 %

Prated

7.60 kW

6.50 kW

SCOP

4.93

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.75 kW

5.71 kW

COP Tj = -7°C

3.16

2.32

Pdh Tj = +2°C

4.09 kW

3.35 kW

COP Tj = +2°C

4.92

3.67

Pdh Tj = +7°C

2.51 kW

2.76 kW

COP Tj = +7°C

6.05

4.65

Pdh Tj = 12°C

1.66 kW

3.40 kW

COP Tj = 12°C

7.59

6.19

Pdh Tj = Tbiv

7.65 kW

6.50 kW

COP Tj = Tbiv

2.67

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.65 kW

6.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3188 kWh

3631 kWh

Buderus Logatherm WLW196i-8 ART190
Configure model
Model name
Buderus Logatherm WLW196i-8 ART190
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.77 kW

2.41 kW

El input

0.75 kW

0.91 kW

COP

5.02

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

178 %

Prated

9.00 kW

7.90 kW

SCOP

6.25

4.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.02 kW

7.93 kW

COP Tj = +2°C

2.96

2.28

Pdh Tj = +7°C

6.08 kW

4.95 kW

COP Tj = +7°C

5.37

3.95

Pdh Tj = 12°C

2.61 kW

3.33 kW

COP Tj = 12°C

8.27

5.89

Pdh Tj = Tbiv

9.02 kW

7.93 kW

COP Tj = Tbiv

2.96

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.02 kW

7.93 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.96

2.28

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1924 kWh

2332 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

126 %

Prated

6.10 kW

6.00 kW

SCOP

4.49

3.22

Tbiv

-20 °C

-18 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

3.44 kW

3.61 kW

COP Tj = -7°C

3.87

2.77

Pdh Tj = +2°C

2.27 kW

2.43 kW

COP Tj = +2°C

5.43

3.89

Pdh Tj = +7°C

1.59 kW

2.79 kW

COP Tj = +7°C

5.75

4.70

Pdh Tj = 12°C

1.69 kW

3.23 kW

COP Tj = 12°C

7.40

5.84

Pdh Tj = Tbiv

5.84 kW

5.38 kW

COP Tj = Tbiv

2.36

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

5.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.87

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.10 kW

6.00 kW

Annual energy consumption Qhe

3346 kWh

4594 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.93

2.06

COP Tj = -15°C (if TOL<-20°C)

2.87

2.06

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

145 %

Prated

7.60 kW

6.50 kW

SCOP

4.93

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.75 kW

5.71 kW

COP Tj = -7°C

3.16

2.32

Pdh Tj = +2°C

4.09 kW

3.35 kW

COP Tj = +2°C

4.92

3.67

Pdh Tj = +7°C

2.51 kW

2.76 kW

COP Tj = +7°C

6.05

4.65

Pdh Tj = 12°C

1.66 kW

3.40 kW

COP Tj = 12°C

7.59

6.19

Pdh Tj = Tbiv

7.65 kW

6.50 kW

COP Tj = Tbiv

2.67

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.65 kW

6.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3188 kWh

3631 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118 %

COP

2.77

Heating up time

02:01 h:min

Standby power input

47.2 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

270 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

77 %

COP

1.82

Heating up time

03:08 h:min

Standby power input

69.0 W

Reference hot water temperature

54.7 °C

Mixed water at 40°C

285 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98 %

COP

2.31

Heating up time

02:37 h:min

Standby power input

52.5 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

268 l

Buderus Logatherm WLW196i-8 ARTS185
Configure model
Model name
Buderus Logatherm WLW196i-8 ARTS185
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.77 kW

2.41 kW

El input

0.75 kW

0.91 kW

COP

5.02

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

247 %

178 %

Prated

9.00 kW

7.90 kW

SCOP

6.25

4.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.02 kW

7.93 kW

COP Tj = +2°C

2.96

2.28

Pdh Tj = +7°C

6.08 kW

4.95 kW

COP Tj = +7°C

5.37

3.95

Pdh Tj = 12°C

2.61 kW

3.33 kW

COP Tj = 12°C

8.27

5.89

Pdh Tj = Tbiv

9.02 kW

7.93 kW

COP Tj = Tbiv

2.96

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.02 kW

7.93 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.96

2.28

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1924 kWh

2332 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

126 %

Prated

6.10 kW

6.00 kW

SCOP

4.49

3.22

Tbiv

-20 °C

-18 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

3.44 kW

3.61 kW

COP Tj = -7°C

3.87

2.77

Pdh Tj = +2°C

2.27 kW

2.43 kW

COP Tj = +2°C

5.43

3.89

Pdh Tj = +7°C

1.59 kW

2.79 kW

COP Tj = +7°C

5.75

4.70

Pdh Tj = 12°C

1.69 kW

3.23 kW

COP Tj = 12°C

7.40

5.84

Pdh Tj = Tbiv

5.84 kW

5.38 kW

COP Tj = Tbiv

2.36

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

5.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.36

1.87

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.10 kW

6.00 kW

Annual energy consumption Qhe

3346 kWh

4594 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.93

2.06

COP Tj = -15°C (if TOL<-20°C)

2.87

2.06

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

145 %

Prated

7.60 kW

6.50 kW

SCOP

4.93

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.75 kW

5.71 kW

COP Tj = -7°C

3.16

2.32

Pdh Tj = +2°C

4.09 kW

3.35 kW

COP Tj = +2°C

4.92

3.67

Pdh Tj = +7°C

2.51 kW

2.76 kW

COP Tj = +7°C

6.05

4.65

Pdh Tj = 12°C

1.66 kW

3.40 kW

COP Tj = 12°C

7.59

6.19

Pdh Tj = Tbiv

7.65 kW

6.50 kW

COP Tj = Tbiv

2.67

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.65 kW

6.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3188 kWh

3631 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.61

Heating up time

02:00 h:min

Standby power input

48.3 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

261 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

87 %

COP

2.01

Heating up time

02:56 h:min

Standby power input

77.0 W

Reference hot water temperature

54.5 °C

Mixed water at 40°C

279 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.37

Heating up time

02:24 h:min

Standby power input

53.7 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

263 l

Buderus Logatherm WLW196i-8 IRE
Configure model
Model name
Buderus Logatherm WLW196i-8 IRE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.85 kW

2.34 kW

El input

0.62 kW

0.91 kW

COP

4.63

2.58

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

167 %

Prated

8.30 kW

7.20 kW

SCOP

6.04

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.31 kW

7.19 kW

COP Tj = +2°C

2.82

2.18

Pdh Tj = +7°C

5.04 kW

4.66 kW

COP Tj = +7°C

5.23

3.70

Pdh Tj = 12°C

2.57 kW

3.17 kW

COP Tj = 12°C

7.97

5.51

Pdh Tj = Tbiv

8.31 kW

7.19 kW

COP Tj = Tbiv

2.82

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.31 kW

7.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.18

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1837 kWh

2270 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

123 %

Prated

6.20 kW

6.00 kW

SCOP

4.30

3.16

Tbiv

-19 °C

-16 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.50 kW

3.49 kW

COP Tj = -7°C

3.40

2.71

Pdh Tj = +2°C

2.28 kW

2.39 kW

COP Tj = +2°C

5.42

3.89

Pdh Tj = +7°C

1.52 kW

2.77 kW

COP Tj = +7°C

6.63

4.62

Pdh Tj = 12°C

1.67 kW

3.25 kW

COP Tj = 12°C

7.23

5.74

Pdh Tj = Tbiv

5.68 kW

5.04 kW

COP Tj = Tbiv

2.30

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.02 kW

4.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.92

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.20 kW

6.00 kW

Annual energy consumption Qhe

3555 kWh

4677 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.49

2.07

COP Tj = -15°C (if TOL<-20°C)

2.61

2.07

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

139 %

Prated

7.30 kW

6.00 kW

SCOP

4.48

3.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.43 kW

5.18 kW

COP Tj = -7°C

3.03

2.29

Pdh Tj = +2°C

3.93 kW

3.10 kW

COP Tj = +2°C

4.19

3.56

Pdh Tj = +7°C

2.54 kW

2.77 kW

COP Tj = +7°C

5.98

4.40

Pdh Tj = 12°C

1.68 kW

3.30 kW

COP Tj = 12°C

7.30

5.61

Pdh Tj = Tbiv

7.29 kW

5.99 kW

COP Tj = Tbiv

2.59

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

5.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3365 kWh

3483 kWh

Buderus Logatherm WLW196i-8 IRB
Configure model
Model name
Buderus Logatherm WLW196i-8 IRB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.85 kW

2.34 kW

El input

0.62 kW

0.91 kW

COP

4.63

2.58

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

167 %

Prated

8.30 kW

7.20 kW

SCOP

6.04

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.31 kW

7.19 kW

COP Tj = +2°C

2.82

2.18

Pdh Tj = +7°C

5.04 kW

4.66 kW

COP Tj = +7°C

5.23

3.70

Pdh Tj = 12°C

2.57 kW

3.17 kW

COP Tj = 12°C

7.97

5.51

Pdh Tj = Tbiv

8.31 kW

7.19 kW

COP Tj = Tbiv

2.82

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.31 kW

7.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.18

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1837 kWh

2270 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

123 %

Prated

6.20 kW

6.00 kW

SCOP

4.30

3.16

Tbiv

-19 °C

-16 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.50 kW

3.49 kW

COP Tj = -7°C

3.40

2.71

Pdh Tj = +2°C

2.28 kW

2.39 kW

COP Tj = +2°C

5.42

3.89

Pdh Tj = +7°C

1.52 kW

2.77 kW

COP Tj = +7°C

6.63

4.62

Pdh Tj = 12°C

1.67 kW

3.25 kW

COP Tj = 12°C

7.23

5.74

Pdh Tj = Tbiv

5.68 kW

5.04 kW

COP Tj = Tbiv

2.30

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.02 kW

4.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.92

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3555 kWh

4677 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.49

2.07

COP Tj = -15°C (if TOL<-20°C)

2.61

2.07

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

139 %

Prated

7.30 kW

6.00 kW

SCOP

4.48

3.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.43 kW

5.18 kW

COP Tj = -7°C

3.03

2.29

Pdh Tj = +2°C

3.93 kW

3.10 kW

COP Tj = +2°C

4.19

3.56

Pdh Tj = +7°C

2.54 kW

2.77 kW

COP Tj = +7°C

5.98

4.40

Pdh Tj = 12°C

1.68 kW

3.30 kW

COP Tj = 12°C

7.30

5.61

Pdh Tj = Tbiv

7.29 kW

5.99 kW

COP Tj = Tbiv

2.59

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

5.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3365 kWh

3483 kWh

Buderus Logatherm WLW196i-8 IRT190
Configure model
Model name
Buderus Logatherm WLW196i-8 IRT190
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.85 kW

2.34 kW

El input

0.62 kW

0.91 kW

COP

4.63

2.58

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

167 %

Prated

8.30 kW

7.20 kW

SCOP

6.04

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.31 kW

7.19 kW

COP Tj = +2°C

2.82

2.18

Pdh Tj = +7°C

5.04 kW

4.66 kW

COP Tj = +7°C

5.23

3.70

Pdh Tj = 12°C

2.57 kW

3.17 kW

COP Tj = 12°C

7.97

5.51

Pdh Tj = Tbiv

8.31 kW

7.19 kW

COP Tj = Tbiv

2.82

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.31 kW

7.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.18

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1837 kWh

2270 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

123 %

Prated

6.20 kW

6.00 kW

SCOP

4.30

3.16

Tbiv

-19 °C

-16 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.50 kW

3.49 kW

COP Tj = -7°C

3.40

2.71

Pdh Tj = +2°C

2.28 kW

2.39 kW

COP Tj = +2°C

5.42

3.89

Pdh Tj = +7°C

1.52 kW

2.77 kW

COP Tj = +7°C

6.63

4.62

Pdh Tj = 12°C

1.67 kW

3.25 kW

COP Tj = 12°C

7.23

5.74

Pdh Tj = Tbiv

5.68 kW

5.04 kW

COP Tj = Tbiv

2.30

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.02 kW

4.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.92

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.20 kW

6.00 kW

Annual energy consumption Qhe

3555 kWh

4677 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.49

2.07

COP Tj = -15°C (if TOL<-20°C)

2.61

2.07

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

139 %

Prated

7.30 kW

6.00 kW

SCOP

4.48

3.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.43 kW

5.18 kW

COP Tj = -7°C

3.03

2.29

Pdh Tj = +2°C

3.93 kW

3.10 kW

COP Tj = +2°C

4.19

3.56

Pdh Tj = +7°C

2.54 kW

2.77 kW

COP Tj = +7°C

5.98

4.40

Pdh Tj = 12°C

1.68 kW

3.30 kW

COP Tj = 12°C

7.30

5.61

Pdh Tj = Tbiv

7.29 kW

5.99 kW

COP Tj = Tbiv

2.59

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

5.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3365 kWh

3483 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118 %

COP

2.77

Heating up time

02:01 h:min

Standby power input

47.0 W

Reference hot water temperature

54.7 °C

Mixed water at 40°C

270 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

77 %

COP

1.82

Heating up time

03:08 h:min

Standby power input

69.0 W

Reference hot water temperature

54.7 °C

Mixed water at 40°C

285 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98 %

COP

2.31

Heating up time

02:37 h:min

Standby power input

53.0 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

268 l

Buderus Logatherm WLW196i-8 IRTS185
Configure model
Model name
Buderus Logatherm WLW196i-8 IRTS185
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.85 kW

2.34 kW

El input

0.62 kW

0.91 kW

COP

4.63

2.58

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

167 %

Prated

8.30 kW

7.20 kW

SCOP

6.04

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.31 kW

7.19 kW

COP Tj = +2°C

2.82

2.18

Pdh Tj = +7°C

5.04 kW

4.66 kW

COP Tj = +7°C

5.23

3.70

Pdh Tj = 12°C

2.57 kW

3.17 kW

COP Tj = 12°C

7.97

5.51

Pdh Tj = Tbiv

8.31 kW

7.19 kW

COP Tj = Tbiv

2.82

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.31 kW

7.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.18

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1837 kWh

2270 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

123 %

Prated

6.20 kW

6.00 kW

SCOP

4.30

3.16

Tbiv

-19 °C

-16 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.50 kW

3.49 kW

COP Tj = -7°C

3.40

2.71

Pdh Tj = +2°C

2.28 kW

2.39 kW

COP Tj = +2°C

5.42

3.89

Pdh Tj = +7°C

1.52 kW

2.77 kW

COP Tj = +7°C

6.63

4.62

Pdh Tj = 12°C

1.67 kW

3.25 kW

COP Tj = 12°C

7.23

5.74

Pdh Tj = Tbiv

5.68 kW

5.04 kW

COP Tj = Tbiv

2.30

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.02 kW

4.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.92

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.20 kW

6.00 kW

Annual energy consumption Qhe

3555 kWh

4677 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.49

2.07

COP Tj = -15°C (if TOL<-20°C)

2.61

2.07

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

139 %

Prated

7.30 kW

6.00 kW

SCOP

4.48

3.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.43 kW

5.18 kW

COP Tj = -7°C

3.03

2.29

Pdh Tj = +2°C

3.93 kW

3.10 kW

COP Tj = +2°C

4.19

3.56

Pdh Tj = +7°C

2.54 kW

2.77 kW

COP Tj = +7°C

5.98

4.40

Pdh Tj = 12°C

1.68 kW

3.30 kW

COP Tj = 12°C

7.30

5.61

Pdh Tj = Tbiv

7.29 kW

5.99 kW

COP Tj = Tbiv

2.59

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

5.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3365 kWh

3483 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.61

Heating up time

02:00 h:min

Standby power input

48.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

261 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

87 %

COP

2.01

Heating up time

02:56 h:min

Standby power input

77.0 W

Reference hot water temperature

54.5 °C

Mixed water at 40°C

279 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.37

Heating up time

02:24 h:min

Standby power input

54.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

263 l

Buderus Logatherm WLW196i.2-6 ARB S+
Configure model
Model name
Buderus Logatherm WLW196i.2-6 ARB S+
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.01 kW

2.60 kW

El input

0.80 kW

0.91 kW

COP

5.01

2.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

164 %

Prated

7.29 kW

7.25 kW

SCOP

6.12

4.17

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.29 kW

7.25 kW

COP Tj = +2°C

3.06

2.19

Pdh Tj = +7°C

4.69 kW

4.78 kW

COP Tj = +7°C

5.56

3.76

Pdh Tj = 12°C

3.64 kW

3.26 kW

COP Tj = 12°C

8.01

5.28

Pdh Tj = Tbiv

7.29 kW

7.25 kW

COP Tj = Tbiv

3.06

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

7.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1591 kWh

2325 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

123 %

Prated

5.72 kW

5.48 kW

SCOP

4.28

3.15

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-18 °C

Pdh Tj = -7°C

3.26 kW

3.47 kW

COP Tj = -7°C

3.63

2.66

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.28 kW

2.42 kW

COP Tj = +2°C

5.41

3.86

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.53 kW

2.83 kW

COP Tj = +7°C

6.76

4.70

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.68 kW

3.31 kW

COP Tj = 12°C

7.17

6.19

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

4.96 kW

4.76 kW

COP Tj = Tbiv

2.44

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.84 kW

4.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.76

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3291 kWh

4288 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.96

4.76

COP Tj = -15°C (if TOL<-20°C)

2.44

1.82

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

140 %

Prated

6.20 kW

5.91 kW

SCOP

5.02

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.54 kW

5.21 kW

COP Tj = -7°C

3.16

2.27

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

3.31 kW

3.27 kW

COP Tj = +2°C

4.86

3.56

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.04 kW

2.84 kW

COP Tj = +7°C

6.72

4.49

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.72 kW

3.34 kW

COP Tj = 12°C

7.96

5.98

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

6.20 kW

5.91 kW

COP Tj = Tbiv

2.72

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.20 kW

5.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.93

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2553 kWh

3413 kWh

Buderus Logatherm WLW196i.2-6 ARE S+
Configure model
Model name
Buderus Logatherm WLW196i.2-6 ARE S+
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.01 kW

2.60 kW

El input

0.80 kW

0.91 kW

COP

5.01

2.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

164 %

Prated

7.29 kW

7.25 kW

SCOP

6.12

4.17

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.29 kW

7.25 kW

COP Tj = +2°C

3.06

2.19

Pdh Tj = +7°C

4.69 kW

4.78 kW

COP Tj = +7°C

5.56

3.76

Pdh Tj = 12°C

3.64 kW

3.26 kW

COP Tj = 12°C

8.01

5.28

Pdh Tj = Tbiv

7.29 kW

7.25 kW

COP Tj = Tbiv

3.06

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

7.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1591 kWh

2325 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

123 %

Prated

5.72 kW

5.48 kW

SCOP

4.28

3.15

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-18 °C

Pdh Tj = -7°C

3.26 kW

3.47 kW

COP Tj = -7°C

3.63

2.66

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.28 kW

2.42 kW

COP Tj = +2°C

5.41

3.86

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.53 kW

2.83 kW

COP Tj = +7°C

6.76

4.70

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.68 kW

3.31 kW

COP Tj = 12°C

7.17

6.19

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

4.96 kW

4.76 kW

COP Tj = Tbiv

2.44

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.84 kW

4.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.76

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.72 kW

5.48 kW

Annual energy consumption Qhe

3291 kWh

4288 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.96

4.76

COP Tj = -15°C (if TOL<-20°C)

2.44

1.82

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

29 dB(A)

29 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

140 %

Prated

6.20 kW

5.91 kW

SCOP

5.02

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.54 kW

5.21 kW

COP Tj = -7°C

3.16

2.27

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

3.31 kW

3.27 kW

COP Tj = +2°C

4.86

3.56

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.04 kW

2.84 kW

COP Tj = +7°C

6.72

4.49

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.72 kW

3.34 kW

COP Tj = 12°C

7.96

5.98

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

6.20 kW

5.91 kW

COP Tj = Tbiv

2.72

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.20 kW

5.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.93

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2553 kWh

3413 kWh

Buderus Logatherm WLW196i.2-6 ART190 S+
Configure model
Model name
Buderus Logatherm WLW196i.2-6 ART190 S+
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.01 kW

2.60 kW

El input

0.80 kW

0.91 kW

COP

5.01

2.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

164 %

Prated

7.29 kW

7.25 kW

SCOP

6.12

4.17

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.29 kW

7.25 kW

COP Tj = +2°C

3.06

2.19

Pdh Tj = +7°C

4.69 kW

4.78 kW

COP Tj = +7°C

5.56

3.76

Pdh Tj = 12°C

3.64 kW

3.26 kW

COP Tj = 12°C

8.01

5.28

Pdh Tj = Tbiv

7.29 kW

7.25 kW

COP Tj = Tbiv

3.06

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

7.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1591 kWh

2325 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

123 %

Prated

5.72 kW

5.48 kW

SCOP

4.28

3.15

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-18 °C

Pdh Tj = -7°C

3.26 kW

3.47 kW

COP Tj = -7°C

3.63

2.66

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.28 kW

2.42 kW

COP Tj = +2°C

5.41

3.86

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.53 kW

2.83 kW

COP Tj = +7°C

6.76

4.70

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.68 kW

3.31 kW

COP Tj = 12°C

7.17

6.19

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

4.96 kW

4.76 kW

COP Tj = Tbiv

2.44

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.84 kW

4.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.76

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.72 kW

5.48 kW

Annual energy consumption Qhe

3291 kWh

4288 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.96

1.82

COP Tj = -15°C (if TOL<-20°C)

2.44

1.82

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

140 %

Prated

6.20 kW

5.91 kW

SCOP

5.02

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.54 kW

5.21 kW

COP Tj = -7°C

3.16

2.27

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

3.31 kW

3.27 kW

COP Tj = +2°C

4.86

3.56

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.04 kW

2.84 kW

COP Tj = +7°C

6.72

4.49

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.72 kW

3.34 kW

COP Tj = 12°C

7.96

5.98

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

6.20 kW

5.91 kW

COP Tj = Tbiv

2.72

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.20 kW

5.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.93

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2553 kWh

3413 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

122 %

COP

2.86

Heating up time

01:55 h:min

Standby power input

45.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

268 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

88 %

COP

2.08

Heating up time

02:51 h:min

Standby power input

57.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

272 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.42

Heating up time

02:26 h:min

Standby power input

49.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

269 l

Buderus Logatherm WLW196i.2-6 ARTS185 S+
Configure model
Model name
Buderus Logatherm WLW196i.2-6 ARTS185 S+
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.01 kW

2.60 kW

El input

0.80 kW

0.91 kW

COP

5.01

2.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

164 %

Prated

7.29 kW

7.25 kW

SCOP

6.12

4.17

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.29 kW

7.25 kW

COP Tj = +2°C

3.06

2.19

Pdh Tj = +7°C

4.69 kW

4.78 kW

COP Tj = +7°C

5.56

3.76

Pdh Tj = 12°C

3.64 kW

3.26 kW

COP Tj = 12°C

8.01

5.28

Pdh Tj = Tbiv

7.29 kW

7.25 kW

COP Tj = Tbiv

3.06

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

7.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.19

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1591 kWh

2325 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

123 %

Prated

5.72 kW

5.48 kW

SCOP

4.28

3.15

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-18 °C

Pdh Tj = -7°C

3.26 kW

3.47 kW

COP Tj = -7°C

3.63

2.66

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.28 kW

2.42 kW

COP Tj = +2°C

5.41

3.86

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.53 kW

2.83 kW

COP Tj = +7°C

6.76

4.70

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.68 kW

3.31 kW

COP Tj = 12°C

7.17

6.19

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

4.96 kW

4.76 kW

COP Tj = Tbiv

2.44

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.84 kW

4.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.39

1.76

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.72 kW

5.48 kW

Annual energy consumption Qhe

3291 kWh

4288 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.96

1.82

COP Tj = -15°C (if TOL<-20°C)

2.44

1.82

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

25 dB(A)

25 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

140 %

Prated

6.20 kW

5.91 kW

SCOP

5.02

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.54 kW

5.21 kW

COP Tj = -7°C

3.16

2.27

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

3.31 kW

3.27 kW

COP Tj = +2°C

4.86

3.56

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.04 kW

2.84 kW

COP Tj = +7°C

6.72

4.49

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.72 kW

3.34 kW

COP Tj = 12°C

7.96

5.98

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

6.20 kW

5.91 kW

COP Tj = Tbiv

2.72

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.20 kW

5.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.93

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2553 kWh

3413 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.64

Heating up time

01:52 h:min

Standby power input

47.0 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

254 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

84 %

COP

2.00

Heating up time

02:48 h:min

Standby power input

58.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

252 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.37

Heating up time

02:11 h:min

Standby power input

51.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

259 l

Buderus Hybrid-Set WLW196i-8 A H
Configure model
Model name
Buderus Hybrid-Set WLW196i-8 A H
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.65 kW

2.85 kW

El input

0.76 kW

1.16 kW

COP

4.81

2.46

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

238 %

157 %

Prated

9.00 kW

7.90 kW

SCOP

6.03

4.00

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.10 kW

7.44 kW

COP Tj = +2°C

3.71

1.98

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.90 kW

4.88 kW

COP Tj = +7°C

5.43

3.25

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

2.69 kW

3.22 kW

COP Tj = 12°C

7.35

5.66

Cdh Tj = +12 °C

1.000

0.960

Pdh Tj = Tbiv

8.10 kW

7.44 kW

COP Tj = Tbiv

3.71

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.10 kW

7.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

1.98

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

5 W

5 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1995 kWh

2640 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

117 %

Prated

6.10 kW

6.00 kW

SCOP

4.12

3.00

Tbiv

-17 °C

-15 °C

TOL

-18 °C

-18 °C

Pdh Tj = -7°C

3.52 kW

3.70 kW

COP Tj = -7°C

3.19

2.55

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.26 kW

2.17 kW

COP Tj = +2°C

5.00

3.33

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.44 kW

2.63 kW

COP Tj = +7°C

6.25

4.65

Cdh Tj = +7 °C

1.000

0.960

Pdh Tj = 12°C

1.97 kW

3.24 kW

COP Tj = 12°C

7.00

5.96

Cdh Tj = +12 °C

0.920

0.960

Pdh Tj = Tbiv

5.30 kW

5.02 kW

COP Tj = Tbiv

2.74

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.46 kW

2.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

2.01

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

5 W

5 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

0.64 kW

3.38 kW

Annual energy consumption Qhe

3653 kWh

4923 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

132 %

Prated

7.60 kW

6.50 kW

SCOP

4.38

3.39

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.44 kW

5.79 kW

COP Tj = -7°C

3.02

2.17

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.77 kW

3.43 kW

COP Tj = +2°C

4.06

3.29

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.46 kW

2.62 kW

COP Tj = +7°C

5.99

4.47

Cdh Tj = +7 °C

1.000

0.960

Pdh Tj = 12°C

1.97 kW

3.23 kW

COP Tj = 12°C

7.26

5.80

Cdh Tj = +12 °C

0.920

0.960

Pdh Tj = Tbiv

7.25 kW

5.79 kW

COP Tj = Tbiv

2.56

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.25 kW

2.26 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.68

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

5 W

5 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

0.00 kW

4.24 kW

Annual energy consumption Qhe

3587 kWh

3966 kWh

Buderus Hybrid-Set WLW196i-6 A H S+
Configure model
Model name
Buderus Hybrid-Set WLW196i-6 A H S+
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.47 kW

2.89 kW

El input

0.73 kW

1.14 kW

COP

4.76

2.53

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

7.30 kW

7.20 kW

SCOP

5.70

3.97

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.57 kW

7.31 kW

COP Tj = +2°C

3.57

2.15

Pdh Tj = +7°C

4.67 kW

5.00 kW

COP Tj = +7°C

5.14

3.31

Pdh Tj = 12°C

2.03 kW

3.29 kW

COP Tj = 12°C

6.97

5.44

Pdh Tj = Tbiv

6.57 kW

7.31 kW

COP Tj = Tbiv

3.57

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.57 kW

7.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.57

2.15

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1710 kWh

2423 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

115 %

Prated

5.70 kW

5.50 kW

SCOP

4.06

2.94

Tbiv

-17 °C

-15 °C

TOL

-18 °C

-18 °C

Pdh Tj = -7°C

3.64 kW

3.29 kW

COP Tj = -7°C

3.19

2.23

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.11 kW

2.24 kW

COP Tj = +2°C

4.91

3.47

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.35 kW

2.71 kW

COP Tj = +7°C

5.91

4.60

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

2.02 kW

3.32 kW

COP Tj = 12°C

6.74

5.73

Cdh Tj = +12 °C

1.000

0.970

Pdh Tj = Tbiv

4.95 kW

4.68 kW

COP Tj = Tbiv

2.80

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.59 kW

2.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

2.30

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

1.16 kW

2.82 kW

Annual energy consumption Qhe

3461 kWh

4613 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

129 %

Prated

6.20 kW

5.90 kW

SCOP

4.61

3.30

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.46 kW

5.07 kW

COP Tj = -7°C

2.92

2.12

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.29 kW

2.95 kW

COP Tj = +2°C

4.60

3.26

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.01 kW

2.55 kW

COP Tj = +7°C

6.01

4.24

Cdh Tj = +7 °C

1.000

0.970

Pdh Tj = 12°C

1.55 kW

3.06 kW

COP Tj = 12°C

6.99

5.54

Cdh Tj = +12 °C

0.910

0.960

Pdh Tj = Tbiv

5.76 kW

5.07 kW

COP Tj = Tbiv

2.57

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.76 kW

5.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.84

WTOL

62 °C

62 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2778 kWh

3694 kWh

Buderus Logatherm WLW196i-8 ARTP120
Configure model
Model name
Buderus Logatherm WLW196i-8 ARTP120
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.78 kW

2.41 kW

El input

0.79 kW

0.93 kW

COP

4.78

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

166 %

Prated

9.00 kW

7.90 kW

SCOP

5.94

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.10 kW

7.44 kW

COP Tj = +2°C

2.99

2.23

Pdh Tj = +7°C

6.17 kW

4.92 kW

COP Tj = +7°C

5.36

3.74

Pdh Tj = 12°C

2.67 kW

3.31 kW

COP Tj = 12°C

7.40

5.47

Pdh Tj = Tbiv

9.10 kW

7.44 kW

COP Tj = Tbiv

2.99

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.10 kW

7.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.99

2.23

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2023 kWh

2491 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

118 %

Prated

6.50 kW

6.80 kW

SCOP

4.00

3.02

Tbiv

-17 °C

-17 °C

TOL

-17 °C

-17 °C

Pdh Tj = -7°C

3.83 kW

4.47 kW

COP Tj = -7°C

3.56

2.63

Pdh Tj = +2°C

2.36 kW

2.49 kW

COP Tj = +2°C

5.16

3.72

Pdh Tj = +7°C

1.61 kW

2.85 kW

COP Tj = +7°C

5.93

4.64

Pdh Tj = 12°C

1.69 kW

3.36 kW

COP Tj = 12°C

6.17

5.85

Pdh Tj = Tbiv

5.64 kW

5.82 kW

COP Tj = Tbiv

2.29

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.64 kW

5.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.29

1.72

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.50 kW

6.80 kW

Annual energy consumption Qhe

4001 kWh

5544 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.44

5.14

COP Tj = -15°C (if TOL<-20°C)

2.43

1.80

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

133 %

Prated

7.60 kW

6.34 kW

SCOP

4.61

3.41

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.58 kW

5.69 kW

COP Tj = -7°C

3.05

2.19

Pdh Tj = +2°C

4.09 kW

3.29 kW

COP Tj = +2°C

4.64

3.40

Pdh Tj = +7°C

2.60 kW

2.78 kW

COP Tj = +7°C

5.67

4.32

Pdh Tj = 12°C

1.69 kW

3.32 kW

COP Tj = 12°C

6.36

5.55

Pdh Tj = Tbiv

7.55 kW

6.34 kW

COP Tj = Tbiv

2.60

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.55 kW

6.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.87

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

25 W

25 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3406 kWh

3842 kWh

Buderus Logatherm WLW196i.2-6 ARTP120 S+
Configure model
Model name
Buderus Logatherm WLW196i.2-6 ARTP120 S+
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.01 kW

2.60 kW

El input

0.84 kW

0.94 kW

COP

4.78

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

158 %

Prated

7.29 kW

7.25 kW

SCOP

5.72

4.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.29 kW

7.25 kW

COP Tj = +2°C

2.95

2.16

Pdh Tj = +7°C

4.69 kW

4.78 kW

COP Tj = +7°C

5.31

3.67

Pdh Tj = 12°C

3.64 kW

3.26 kW

COP Tj = 12°C

7.44

5.10

Pdh Tj = Tbiv

7.29 kW

7.25 kW

COP Tj = Tbiv

2.95

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

7.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.95

2.16

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1703 kWh

2407 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

119 %

Prated

5.72 kW

5.48 kW

SCOP

4.07

3.04

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-18 °C

Pdh Tj = -7°C

3.26 kW

3.47 kW

COP Tj = -7°C

3.52

2.61

Pdh Tj = +2°C

2.28 kW

2.42 kW

COP Tj = +2°C

5.09

3.73

Pdh Tj = +7°C

1.53 kW

2.83 kW

COP Tj = +7°C

6.15

4.52

Pdh Tj = 12°C

1.68 kW

3.31 kW

COP Tj = 12°C

6.53

5.91

Pdh Tj = Tbiv

4.96 kW

4.76 kW

COP Tj = Tbiv

2.39

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.84 kW

4.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.33

1.74

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.72 kW

5.48 kW

Annual energy consumption Qhe

3463 kWh

4440 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.96

4.76

COP Tj = -15°C (if TOL<-20°C)

2.39

1.80

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

135 %

Prated

6.20 kW

5.91 kW

SCOP

4.73

3.45

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.54 kW

5.21 kW

COP Tj = -7°C

3.07

2.24

Pdh Tj = +2°C

3.31 kW

3.27 kW

COP Tj = +2°C

4.64

3.47

Pdh Tj = +7°C

2.05 kW

2.84 kW

COP Tj = +7°C

6.21

4.33

Pdh Tj = 12°C

1.72 kW

3.34 kW

COP Tj = 12°C

7.18

5.72

Pdh Tj = Tbiv

6.20 kW

5.91 kW

COP Tj = Tbiv

2.65

1.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.20 kW

5.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.91

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

50 W

50 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2707 kWh

3535 kWh

Buderus Logatherm WLW196i-8 IRTP120
Configure model
Model name
Buderus Logatherm WLW196i-8 IRTP120
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.85 kW

2.41 kW

El input

0.65 kW

0.93 kW

COP

4.41

2.58

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

160 %

Prated

8.30 kW

7.20 kW

SCOP

5.73

4.08

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.31 kW

7.19 kW

COP Tj = +2°C

2.75

2.15

Pdh Tj = +7°C

5.04 kW

4.66 kW

COP Tj = +7°C

5.00

3.61

Pdh Tj = 12°C

2.57 kW

3.17 kW

COP Tj = 12°C

7.39

5.24

Pdh Tj = Tbiv

8.31 kW

7.19 kW

COP Tj = Tbiv

2.75

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.31 kW

7.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

2.15

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1937 kWh

2360 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

120 %

Prated

6.20 kW

6.00 kW

SCOP

4.08

3.07

Tbiv

-19 °C

-16 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.50 kW

3.49 kW

COP Tj = -7°C

3.29

2.65

Pdh Tj = +2°C

2.28 kW

2.39 kW

COP Tj = +2°C

5.10

3.78

Pdh Tj = +7°C

1.52 kW

2.77 kW

COP Tj = +7°C

6.02

4.44

Pdh Tj = 12°C

1.67 kW

3.25 kW

COP Tj = 12°C

6.59

5.46

Pdh Tj = Tbiv

5.68 kW

5.04 kW

COP Tj = Tbiv

2.25

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.02 kW

4.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.89

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.20 kW

6.00 kW

Annual energy consumption Qhe

3744 kWh

4819 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.49

4.72

COP Tj = -15°C (if TOL<-20°C)

2.55

2.04

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

135 %

Prated

7.30 kW

6.00 kW

SCOP

4.27

3.44

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.43 kW

5.18 kW

COP Tj = -7°C

2.95

2.26

Pdh Tj = +2°C

3.93 kW

3.10 kW

COP Tj = +2°C

5.10

3.47

Pdh Tj = +7°C

2.54 kW

2.77 kW

COP Tj = +7°C

5.67

4.24

Pdh Tj = 12°C

1.68 kW

3.30 kW

COP Tj = 12°C

6.63

5.37

Pdh Tj = Tbiv

7.29 kW

5.99 kW

COP Tj = Tbiv

2.53

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

5.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.96

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

7 W

7 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3534 kWh

3602 kWh