Certificate holders

Subtype

Bosch Compress 7000iAW 17 OR and IR, Compress 6000 AW-17, Bosch CS7001iAW 17

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
011-1W0126
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Bosch Compress 7000iAW 17 OR and IR, Compress 6000 AW-17, Bosch CS7001iAW 17
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,000 kg

Certification Date
18.07.2017
Testing basis
HP KEYMARK certification scheme rules rev. 8
Generate PDF Export model CSV
  • Number of models 18

Models

Bosch CS7000iAW 17 IRMS-T
Configure model
Model name
Bosch CS7000iAW 17 IRMS-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.08 kW

4.10 kW

El input

1.04 kW

1.63 kW

COP

4.90

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

166 %

Prated

13.44 kW

12.41 kW

SCOP

6.12

4.23

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.44 kW

12.41 kW

COP Tj = +2°C

2.86

2.21

Pdh Tj = +7°C

8.54 kW

8.58 kW

COP Tj = +7°C

5.31

3.64

Pdh Tj = 12°C

4.07 kW

5.86 kW

COP Tj = 12°C

7.94

5.48

Pdh Tj = Tbiv

13.44 kW

12.41 kW

COP Tj = Tbiv

2.86

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.44 kW

12.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.21

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2931 kWh

3916 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

123 %

Prated

10.00 kW

9.40 kW

SCOP

4.33

3.16

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

6.09 kW

5.63 kW

COP Tj = -7°C

3.68

2.71

Pdh Tj = +2°C

3.66 kW

4.40 kW

COP Tj = +2°C

5.48

3.89

Pdh Tj = +7°C

2.70 kW

5.06 kW

COP Tj = +7°C

6.48

4.75

Pdh Tj = 12°C

6.23 kW

5.98 kW

COP Tj = 12°C

7.42

5.99

Pdh Tj = Tbiv

8.29 kW

8.23 kW

COP Tj = Tbiv

2.52

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.64 kW

8.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.80

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.40 kW

Annual energy consumption Qhe

5697 kWh

7343 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.01

2.01

COP Tj = -15°C (if TOL<-20°C)

2.72

2.01

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

140 %

Prated

12.13 kW

10.00 kW

SCOP

4.92

3.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.89 kW

8.44 kW

COP Tj = -7°C

2.98

2.25

Pdh Tj = +2°C

6.78 kW

5.45 kW

COP Tj = +2°C

4.91

3.56

Pdh Tj = +7°C

4.05 kW

4.98 kW

COP Tj = +7°C

6.33

4.44

Pdh Tj = 12°C

3.00 kW

5.93 kW

COP Tj = 12°C

7.60

5.76

Pdh Tj = Tbiv

12.13 kW

10.00 kW

COP Tj = Tbiv

2.56

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.13 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5090 kWh

5794 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.30

Heating up time

01:59 h:min

Standby power input

61.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

77 %

COP

1.78

Heating up time

02:51 h:min

Standby power input

92.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

89 %

COP

2.08

Heating up time

02:27 h:min

Standby power input

67.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

259 l

Bosch CS7000iAW 17 IRM-T
Configure model
Model name
Bosch CS7000iAW 17 IRM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.08 kW

4.10 kW

El input

1.04 kW

1.63 kW

COP

4.90

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

166 %

Prated

13.44 kW

12.41 kW

SCOP

6.12

4.23

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.44 kW

12.41 kW

COP Tj = +2°C

2.86

2.21

Pdh Tj = +7°C

8.54 kW

8.58 kW

COP Tj = +7°C

5.31

3.64

Pdh Tj = 12°C

4.07 kW

5.86 kW

COP Tj = 12°C

7.94

5.48

Pdh Tj = Tbiv

13.44 kW

12.41 kW

COP Tj = Tbiv

2.86

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.44 kW

12.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.21

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2931 kWh

3916 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

123 %

Prated

10.00 kW

9.40 kW

SCOP

4.33

3.16

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

6.09 kW

5.63 kW

COP Tj = -7°C

3.68

2.71

Pdh Tj = +2°C

3.66 kW

4.40 kW

COP Tj = +2°C

5.48

3.89

Pdh Tj = +7°C

2.70 kW

5.06 kW

COP Tj = +7°C

6.48

4.75

Pdh Tj = 12°C

6.23 kW

5.98 kW

COP Tj = 12°C

7.42

5.99

Pdh Tj = Tbiv

8.29 kW

8.23 kW

COP Tj = Tbiv

2.52

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.64 kW

8.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.80

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.40 kW

Annual energy consumption Qhe

5697 kWh

7343 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.01

2.01

COP Tj = -15°C (if TOL<-20°C)

2.72

2.01

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

140 %

Prated

12.13 kW

10.00 kW

SCOP

4.92

3.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.89 kW

8.44 kW

COP Tj = -7°C

2.98

2.25

Pdh Tj = +2°C

6.78 kW

5.45 kW

COP Tj = +2°C

4.91

3.56

Pdh Tj = +7°C

4.05 kW

4.98 kW

COP Tj = +7°C

6.33

4.44

Pdh Tj = 12°C

3.00 kW

5.93 kW

COP Tj = 12°C

7.60

5.76

Pdh Tj = Tbiv

12.13 kW

10.00 kW

COP Tj = Tbiv

2.56

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.13 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5090 kWh

5794 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

107 %

COP

2.49

Heating up time

01:57 h:min

Standby power input

59.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

266 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

78 %

COP

1.82

Heating up time

02:48 h:min

Standby power input

81.0 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

272 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.12

Heating up time

02:24 h:min

Standby power input

54.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

269 l

Bosch CS7000iAW 17 IRB-T
Configure model
Model name
Bosch CS7000iAW 17 IRB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.08 kW

4.10 kW

El input

1.04 kW

1.63 kW

COP

4.90

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

166 %

Prated

13.44 kW

12.41 kW

SCOP

6.12

4.23

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.44 kW

12.41 kW

COP Tj = +2°C

2.86

2.21

Pdh Tj = +7°C

8.54 kW

8.58 kW

COP Tj = +7°C

5.31

3.64

Pdh Tj = 12°C

4.07 kW

5.86 kW

COP Tj = 12°C

7.94

5.48

Pdh Tj = Tbiv

13.44 kW

12.41 kW

COP Tj = Tbiv

2.86

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.44 kW

12.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.21

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2931 kWh

3916 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

123 %

Prated

10.00 kW

9.40 kW

SCOP

4.33

3.16

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

6.09 kW

5.63 kW

COP Tj = -7°C

3.68

2.71

Pdh Tj = +2°C

3.66 kW

4.40 kW

COP Tj = +2°C

5.48

3.89

Pdh Tj = +7°C

2.70 kW

5.06 kW

COP Tj = +7°C

6.48

4.75

Pdh Tj = 12°C

6.23 kW

5.98 kW

COP Tj = 12°C

7.42

5.99

Pdh Tj = Tbiv

8.29 kW

8.23 kW

COP Tj = Tbiv

2.52

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.64 kW

8.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.80

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5697 kWh

7343 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.01

2.01

COP Tj = -15°C (if TOL<-20°C)

2.72

2.01

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

140 %

Prated

12.13 kW

10.00 kW

SCOP

4.92

3.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.89 kW

8.44 kW

COP Tj = -7°C

2.98

2.25

Pdh Tj = +2°C

6.78 kW

5.45 kW

COP Tj = +2°C

4.91

3.56

Pdh Tj = +7°C

4.05 kW

4.98 kW

COP Tj = +7°C

6.33

4.44

Pdh Tj = 12°C

3.00 kW

5.93 kW

COP Tj = 12°C

7.60

5.76

Pdh Tj = Tbiv

12.13 kW

10.00 kW

COP Tj = Tbiv

2.56

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.13 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5090 kWh

5794 kWh

Bosch CS7000iAW 17 IRE-T
Configure model
Model name
Bosch CS7000iAW 17 IRE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.08 kW

4.10 kW

El input

1.04 kW

1.63 kW

COP

4.90

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

166 %

Prated

13.44 kW

12.41 kW

SCOP

6.12

4.23

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.44 kW

12.41 kW

COP Tj = +2°C

2.86

2.21

Pdh Tj = +7°C

8.54 kW

8.58 kW

COP Tj = +7°C

5.31

3.64

Pdh Tj = 12°C

4.07 kW

5.86 kW

COP Tj = 12°C

7.94

5.48

Pdh Tj = Tbiv

13.44 kW

12.41 kW

COP Tj = Tbiv

2.86

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.44 kW

12.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.21

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2931 kWh

3916 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

123 %

Prated

10.00 kW

9.40 kW

SCOP

4.33

3.16

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

6.09 kW

5.63 kW

COP Tj = -7°C

3.68

2.71

Pdh Tj = +2°C

3.66 kW

4.40 kW

COP Tj = +2°C

5.48

3.89

Pdh Tj = +7°C

2.70 kW

5.06 kW

COP Tj = +7°C

6.48

4.75

Pdh Tj = 12°C

6.23 kW

5.98 kW

COP Tj = 12°C

7.42

5.99

Pdh Tj = Tbiv

8.29 kW

8.23 kW

COP Tj = Tbiv

2.52

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.64 kW

8.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.80

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.40 kW

Annual energy consumption Qhe

5697 kWh

7343 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.01

2.01

COP Tj = -15°C (if TOL<-20°C)

2.72

2.01

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

140 %

Prated

12.13 kW

10.00 kW

SCOP

4.92

3.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.89 kW

8.44 kW

COP Tj = -7°C

2.98

2.25

Pdh Tj = +2°C

6.78 kW

5.45 kW

COP Tj = +2°C

4.91

3.56

Pdh Tj = +7°C

4.05 kW

4.98 kW

COP Tj = +7°C

6.33

4.44

Pdh Tj = 12°C

3.00 kW

5.93 kW

COP Tj = 12°C

7.60

5.76

Pdh Tj = Tbiv

12.13 kW

10.00 kW

COP Tj = Tbiv

2.56

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.13 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5090 kWh

5794 kWh

Bosch CS7000iAW 17 ORMS-T
Configure model
Model name
Bosch CS7000iAW 17 ORMS-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.30

Heating up time

01:59 h:min

Standby power input

61.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

77 %

COP

1.78

Heating up time

02:51 h:min

Standby power input

92.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

89 %

COP

2.08

Heating up time

02:27 h:min

Standby power input

67.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

259 l

Bosch CS7000iAW 17 ORM-T
Configure model
Model name
Bosch CS7000iAW 17 ORM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

107 %

COP

2.49

Heating up time

01:57 h:min

Standby power input

58.5 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

266 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

78 %

COP

1.82

Heating up time

02:48 h:min

Standby power input

80.7 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

272 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.12

Heating up time

02:24 h:min

Standby power input

64.3 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

269 l

Bosch CS7000iAW 17 ORB-T
Configure model
Model name
Bosch CS7000iAW 17 ORB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Bosch CS7000iAW 17 ORE-T
Configure model
Model name
Bosch CS7000iAW 17 ORE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Bosch Compress 6000 AW-17 AWB
Configure model
Model name
Bosch Compress 6000 AW-17 AWB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Bosch Compress 6000 AW-17 AWM
Configure model
Model name
Bosch Compress 6000 AW-17 AWM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

107 %

COP

2.49

Heating up time

01:57 h:min

Standby power input

58.5 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

266 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

78 %

COP

1.82

Heating up time

02:48 h:min

Standby power input

80.7 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

272 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.12

Heating up time

02:24 h:min

Standby power input

64.3 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

269 l

Bosch Compress 6000 AW-17 AWMS
Configure model
Model name
Bosch Compress 6000 AW-17 AWMS
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.30

Heating up time

01:59 h:min

Standby power input

61.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

77 %

COP

1.78

Heating up time

02:51 h:min

Standby power input

92.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

89 %

COP

2.08

Heating up time

02:27 h:min

Standby power input

67.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

259 l

Bosch Compress 6000 AW-17 AWE
Configure model
Model name
Bosch Compress 6000 AW-17 AWE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Bosch CS7001iAW 17 ORMS-T
Configure model
Model name
Bosch CS7001iAW 17 ORMS-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.30

Heating up time

01:59 h:min

Standby power input

61.0 W

Reference hot water temperature

51.4 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

77 %

COP

1.78

Heating up time

02:51 h:min

Standby power input

92.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

89 %

COP

2.08

Heating up time

02:27 h:min

Standby power input

67.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

259 l

Bosch CS7001iAW 17 ORM-T
Configure model
Model name
Bosch CS7001iAW 17 ORM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

107 %

COP

2.49

Heating up time

01:57 h:min

Standby power input

58.5 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

266 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

78 %

COP

1.82

Heating up time

02:48 h:min

Standby power input

80.7 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

272 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.12

Heating up time

02:24 h:min

Standby power input

64.3 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

269 l

Bosch CS7001iAW 17 ORB-T
Configure model
Model name
Bosch CS7001iAW 17 ORB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Bosch CS7001iAW 17 ORE-T
Configure model
Model name
Bosch CS7001iAW 17 ORE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.48 kW

El input

1.16 kW

1.63 kW

COP

4.87

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

170 %

Prated

14.30 kW

12.50 kW

SCOP

6.13

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.85

2.18

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.37

3.81

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

8.00

5.61

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.85

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.18

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3115 kWh

3852 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

123 %

Prated

10.00 kW

9.10 kW

SCOP

4.11

3.15

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.71

2.68

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.64

3.86

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

6.14

4.76

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

7.41

6.23

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.21

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.65

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6000 kWh

7117 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

1.96

COP Tj = -15°C (if TOL<-20°C)

2.66

1.96

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

12.00 kW

10.00 kW

SCOP

4.84

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.87

2.25

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.84

3.64

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.41

4.49

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

7.31

5.79

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.43

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5117 kWh

5721 kWh

Bosch CS7001iAW 17 ORMB-T
Configure model
Model name
Bosch CS7001iAW 17 ORMB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.63 kW

4.32 kW

El input

1.21 kW

1.66 kW

COP

4.66

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

229 %

166 %

Prated

14.30 kW

12.50 kW

SCOP

5.79

4.22

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.59 kW

12.49 kW

COP Tj = +2°C

2.81

2.15

Pdh Tj = +7°C

8.92 kW

8.08 kW

COP Tj = +7°C

5.10

3.73

Pdh Tj = 12°C

4.16 kW

5.99 kW

COP Tj = 12°C

7.44

5.42

Pdh Tj = Tbiv

14.59 kW

12.49 kW

COP Tj = Tbiv

2.81

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.59 kW

12.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

2.15

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3299 kWh

3959 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

120 %

Prated

10.00 kW

9.10 kW

SCOP

3.94

3.08

Tbiv

-19 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

6.20 kW

5.60 kW

COP Tj = -7°C

3.59

2.64

Pdh Tj = +2°C

4.91 kW

4.40 kW

COP Tj = +2°C

4.43

3.76

Pdh Tj = +7°C

5.34 kW

5.07 kW

COP Tj = +7°C

5.81

4.60

Pdh Tj = 12°C

6.28 kW

6.00 kW

COP Tj = 12°C

6.92

6.03

Pdh Tj = Tbiv

9.25 kW

7.90 kW

COP Tj = Tbiv

2.17

1.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.63

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.10 kW

Annual energy consumption Qhe

6251 kWh

7274 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.92

7.13

COP Tj = -15°C (if TOL<-20°C)

2.59

1.94

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

138 %

Prated

12.00 kW

10.00 kW

SCOP

4.64

3.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.36 kW

9.51 kW

COP Tj = -7°C

2.82

2.22

Pdh Tj = +2°C

6.84 kW

5.60 kW

COP Tj = +2°C

4.64

3.56

Pdh Tj = +7°C

4.21 kW

5.07 kW

COP Tj = +7°C

6.02

4.36

Pdh Tj = 12°C

3.03 kW

6.01 kW

COP Tj = 12°C

6.87

5.58

Pdh Tj = Tbiv

12.26 kW

10.11 kW

COP Tj = Tbiv

2.40

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.26 kW

10.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.88

WTOL

60 °C

60 °C

Poff

24 W

24 W

PTO

41 W

41 W

PSB

24 W

24 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5346 kWh

5861 kWh

Bosch CS7000iAW 17 IRMB-T
Configure model
Model name
Bosch CS7000iAW 17 IRMB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.08 kW

4.10 kW

El input

1.09 kW

1.68 kW

COP

4.68

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

162 %

Prated

13.44 kW

12.41 kW

SCOP

5.78

4.12

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.44 kW

12.41 kW

COP Tj = +2°C

2.82

2.17

Pdh Tj = +7°C

8.54 kW

8.58 kW

COP Tj = +7°C

5.05

3.56

Pdh Tj = 12°C

4.07 kW

5.86 kW

COP Tj = 12°C

7.38

5.30

Pdh Tj = Tbiv

13.44 kW

12.41 kW

COP Tj = Tbiv

2.82

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.44 kW

12.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.17

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3105 kWh

4025 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

120 %

Prated

10.00 kW

9.40 kW

SCOP

4.15

3.09

Tbiv

-17 °C

-17 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

6.09 kW

5.63 kW

COP Tj = -7°C

3.56

2.66

Pdh Tj = +2°C

3.66 kW

4.40 kW

COP Tj = +2°C

5.20

3.79

Pdh Tj = +7°C

2.70 kW

5.06 kW

COP Tj = +7°C

6.06

4.61

Pdh Tj = 12°C

6.23 kW

5.98 kW

COP Tj = 12°C

6.94

5.78

Pdh Tj = Tbiv

8.29 kW

8.23 kW

COP Tj = Tbiv

2.46

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.64 kW

8.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.78

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.00 kW

9.40 kW

Annual energy consumption Qhe

5947 kWh

7507 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.01

7.48

COP Tj = -15°C (if TOL<-20°C)

2.65

1.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

136 %

Prated

12.13 kW

10.00 kW

SCOP

4.70

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.89 kW

8.44 kW

COP Tj = -7°C

2.92

2.22

Pdh Tj = +2°C

6.78 kW

5.45 kW

COP Tj = +2°C

4.69

3.48

Pdh Tj = +7°C

4.05 kW

4.98 kW

COP Tj = +7°C

5.96

4.32

Pdh Tj = 12°C

3.00 kW

5.93 kW

COP Tj = 12°C

7.04

5.57

Pdh Tj = Tbiv

12.13 kW

10.00 kW

COP Tj = Tbiv

2.52

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.13 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.86

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

23 W

23 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5335 kWh

5935 kWh