6,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
34.97 kW
31.56 kW
El input
7.76 kW
11.04 kW
COP
4.51
2.86
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
failed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
157 %
Prated
59.64 kW
55.34 kW
SCOP
5.28
4.13
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
59.64 kW
55.34 kW
COP Tj = +2°C
3.93
2.77
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
38.34 kW
35.58 kW
COP Tj = +7°C
5.00
3.69
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
17.04 kW
15.81 kW
COP Tj = 12°C
5.79
4.85
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
59.64 kW
55.34 kW
COP Tj = Tbiv
3.93
2.77
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
59.64 kW
55.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.93
2.77
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
11 W
11 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
15055 kWh
17857 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
160 %
Prated
59.64 kW
55.34 kW
SCOP
5.29
4.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
35.77 kW
33.80 kW
COP Tj = -7°C
5.14
3.85
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
21.97 kW
20.39 kW
COP Tj = +2°C
5.71
4.59
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
16.74 kW
16.35 kW
COP Tj = +7°C
5.86
4.85
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
16.58 kW
16.38 kW
COP Tj = 12°C
5.58
4.88
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
59.64 kW
55.34 kW
COP Tj = Tbiv
3.93
2.77
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
59.64 kW
55.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.93
2.77
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
11 W
11 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
27759 kWh
32491 kWh
Pdh Tj = -15°C (if TOL<-20°C)
59.64
55.34
COP Tj = -15°C (if TOL<-20°C)
3.93
2.77
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
155 %
Prated
59.64 kW
55.34 kW
SCOP
5.19
4.07
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
52.76 kW
48.96 kW
COP Tj = -7°C
4.26
3.01
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
32.11 kW
29.80 kW
COP Tj = +2°C
5.23
4.11
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
20.64 kW
19.16 kW
COP Tj = +7°C
5.74
4.84
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
16.56 kW
16.33 kW
COP Tj = 12°C
5.58
4.66
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
59.64 kW
55.34 kW
COP Tj = Tbiv
3.93
2.77
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
59.64 kW
55.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.93
2.77
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
11 W
11 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
23714 kWh
28063 kWh