Certificate holders

Subtype

TTF 59.5

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0459
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTF 59.5
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

6,300 kg

Certification Date
15.03.2021
Testing basis
HP KEYMARK certification scheme rules V8
Generate PDF Export model CSV
  • Number of models 1

Models

TTF 59.5
Configure model
Model name
TTF 59.5
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

34.97 kW

31.56 kW

El input

7.76 kW

11.04 kW

COP

4.51

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

failed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

59.64 kW

55.34 kW

SCOP

5.28

4.13

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

59.64 kW

55.34 kW

COP Tj = +2°C

3.93

2.77

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

38.34 kW

35.58 kW

COP Tj = +7°C

5.00

3.69

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

17.04 kW

15.81 kW

COP Tj = 12°C

5.79

4.85

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

15055 kWh

17857 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

160 %

Prated

59.64 kW

55.34 kW

SCOP

5.29

4.20

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

35.77 kW

33.80 kW

COP Tj = -7°C

5.14

3.85

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

21.97 kW

20.39 kW

COP Tj = +2°C

5.71

4.59

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

16.74 kW

16.35 kW

COP Tj = +7°C

5.86

4.85

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

16.58 kW

16.38 kW

COP Tj = 12°C

5.58

4.88

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

27759 kWh

32491 kWh

Pdh Tj = -15°C (if TOL<-20°C)

59.64

55.34

COP Tj = -15°C (if TOL<-20°C)

3.93

2.77

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

155 %

Prated

59.64 kW

55.34 kW

SCOP

5.19

4.07

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

52.76 kW

48.96 kW

COP Tj = -7°C

4.26

3.01

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

32.11 kW

29.80 kW

COP Tj = +2°C

5.23

4.11

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

20.64 kW

19.16 kW

COP Tj = +7°C

5.74

4.84

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

16.56 kW

16.33 kW

COP Tj = 12°C

5.58

4.66

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

59.64 kW

55.34 kW

COP Tj = Tbiv

3.93

2.77

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

59.64 kW

55.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.93

2.77

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

23714 kWh

28063 kWh