Certificate holders

Subtype

TTF 44.5

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0458
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTF 44.5
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

4,400 kg

Certification Date
15.03.2021
Testing basis
HP KEYMARK certification scheme rules V8
Generate PDF Export model CSV
  • Number of models 1

Models

TTF 44.5
Configure model
Model name
TTF 44.5
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

26.71 kW

22.39 kW

El input

5.81 kW

7.52 kW

COP

4.60

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

failed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

220 %

167 %

Prated

38.06 kW

35.62 kW

SCOP

5.70

4.38

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

38.06 kW

35.62 kW

COP Tj = +2°C

4.29

2.95

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

24.47 kW

22.90 kW

COP Tj = +7°C

5.35

3.89

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

12.71 kW

12.48 kW

COP Tj = 12°C

6.31

5.17

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

38.06 kW

35.62 kW

COP Tj = Tbiv

4.29

2.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

38.06 kW

35.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.95

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

8920 kWh

10862 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

174 %

Prated

38.06 kW

35.62 kW

SCOP

5.86

4.55

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

23.04 kW

21.56 kW

COP Tj = -7°C

5.57

4.12

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

14.02 kW

13.12 kW

COP Tj = +2°C

6.27

5.02

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

12.71 kW

12.56 kW

COP Tj = +7°C

6.35

5.32

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

12.70 kW

12.65 kW

COP Tj = 12°C

6.19

5.49

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

38.06 kW

35.62 kW

COP Tj = Tbiv

4.29

2.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

38.06 kW

35.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.95

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

16014 kWh

19290 kWh

Pdh Tj = -15°C (if TOL<-20°C)

38.06

35.62

COP Tj = -15°C (if TOL<-20°C)

4.29

2.95

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

168 %

Prated

38.06 kW

35.62 kW

SCOP

5.65

4.39

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

33.67 kW

31.51 kW

COP Tj = -7°C

4.56

3.21

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

20.49 kW

19.18 kW

COP Tj = +2°C

5.68

4.39

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

13.18 kW

12.33 kW

COP Tj = +7°C

6.28

5.16

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

12.70 kW

12.57 kW

COP Tj = 12°C

6.31

5.34

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

38.06 kW

35.62 kW

COP Tj = Tbiv

4.29

2.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

38.06 kW

35.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.95

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

13917 kWh

16768 kWh