9,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
52.18 kW
48.32 kW
El input
11.09 kW
17.02 kW
COP
4.71
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
failed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
160 %
Prated
84.67 kW
79.00 kW
SCOP
5.25
4.21
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
84.67 kW
79.00 kW
COP Tj = +2°C
3.97
2.72
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
54.43 kW
50.79 kW
COP Tj = +7°C
4.85
3.60
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
24.19 kW
24.07 kW
COP Tj = 12°C
5.85
5.16
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
84.67 kW
79.00 kW
COP Tj = Tbiv
3.97
2.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
84.67 kW
79.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.97
2.72
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
21524 kWh
23056 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
165 %
Prated
84.67 kW
79.00 kW
SCOP
5.30
4.32
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
51.25 kW
48.52 kW
COP Tj = -7°C
5.06
3.85
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
31.20 kW
29.11 kW
COP Tj = +2°C
5.81
4.83
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
24.49 kW
24.11 kW
COP Tj = +7°C
5.85
5.20
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
24.39 kW
24.22 kW
COP Tj = 12°C
5.66
5.27
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
84.67 kW
79.00 kW
COP Tj = Tbiv
3.97
2.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
84.67 kW
79.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.97
2.72
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
39378 kWh
45048 kWh
Pdh Tj = -15°C (if TOL<-20°C)
84.67
79.00
COP Tj = -15°C (if TOL<-20°C)
3.97
2.72
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
157 %
Prated
84.67 kW
79.00 kW
SCOP
5.17
4.13
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
74.90 kW
69.88 kW
COP Tj = -7°C
4.26
3.00
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
45.59 kW
42.54 kW
COP Tj = +2°C
5.14
4.08
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
29.31 kW
27.35 kW
COP Tj = +7°C
5.81
4.94
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
24.37 kW
24.08 kW
COP Tj = 12°C
5.65
5.16
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
84.67 kW
79.00 kW
COP Tj = Tbiv
3.97
2.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
84.67 kW
79.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.97
2.72
WTOL
65 °C
65 °C
Poff
9 W
9 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
33804 kWh
39457 kWh