2,200 kg
Heating
EN 14511-2
Medium temperature
Heat output
16.71 kW
El input
5.90 kW
COP
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level outdoor
72 dB(A)
EN 14825
Medium temperature
ηs
126 %
Prated
13.00 kW
SCOP
3.24
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
11.98 kW
COP Tj = -7°C
2.05
Cdh Tj = -7 °C
0.980
Pdh Tj = +2°C
7.41 kW
COP Tj = +2°C
3.19
Cdh Tj = +2 °C
0.980
Pdh Tj = +7°C
5.70 kW
COP Tj = +7°C
4.18
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
6.38 kW
COP Tj = 12°C
5.14
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
11.98 kW
COP Tj = Tbiv
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.78
WTOL
55 °C
Poff
18 W
PTO
18 W
PSB
18 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
2.59 kW
Annual energy consumption Qhe
8292 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
110 %
COP
2.62
Heating up time
1:52 h:min
Standby power input
62.6 W
Reference hot water temperature
52.8 °C
Mixed water at 40°C
372 l
Heating
EN 14511-2
Medium temperature
Heat output
16.71 kW
El input
5.90 kW
COP
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level outdoor
72 dB(A)
EN 14825
Medium temperature
ηs
126 %
Prated
13.00 kW
SCOP
3.24
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
11.98 kW
COP Tj = -7°C
2.05
Cdh Tj = -7 °C
0.980
Pdh Tj = +2°C
7.41 kW
COP Tj = +2°C
3.19
Cdh Tj = +2 °C
0.980
Pdh Tj = +7°C
5.70 kW
COP Tj = +7°C
4.18
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
6.38 kW
COP Tj = 12°C
5.14
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
11.98 kW
COP Tj = Tbiv
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.78
WTOL
55 °C
Poff
18 W
PTO
18 W
PSB
18 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
2.59 kW
Annual energy consumption Qhe
8292 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
110 %
COP
2.62
Heating up time
1:52 h:min
Standby power input
62.6 W
Reference hot water temperature
52.8 °C
Mixed water at 40°C
372 l