0,870 kg
Heating
EN 14511-2
Medium temperature
Heat output
5.00 kW
El input
1.98 kW
COP
2.53
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level outdoor
64 dB(A)
EN 14825
Medium temperature
ηs
127 %
Prated
6.00 kW
SCOP
3.26
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
5.52 kW
COP Tj = -7°C
2.22
Cdh Tj = -7 °C
0.970
Pdh Tj = +2°C
3.31 kW
COP Tj = +2°C
3.13
Cdh Tj = +2 °C
0.970
Pdh Tj = +7°C
2.46 kW
COP Tj = +7°C
4.19
Cdh Tj = +7 °C
0.970
Pdh Tj = 12°C
2.98 kW
COP Tj = 12°C
5.52
Cdh Tj = +12 °C
0.970
Pdh Tj = Tbiv
5.22 kW
COP Tj = Tbiv
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.78
WTOL
55 °C
Poff
18 W
PTO
18 W
PSB
18 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
1.66 kW
Annual energy consumption Qhe
3808 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.53
Heating up time
2.59 h:min
Standby power input
62.2 W
Reference hot water temperature
51.7 °C
Mixed water at 40°C
379 l