Certificate holders

Subtype

DAIKIN ALTHERMA M HW 200L

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0521
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA M HW 200L
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R134a
Mass of Refrigerant

1,000 kg

Certification Date
14.03.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9 (as of 2021-03)
Generate PDF Export model CSV
  • Number of models 2

Models

EKHHE200CV37
Configure model
Model name
EKHHE200CV37
Units
Indoor
Climate zone (for heating)
Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

53 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

162 %

COP

3.89

Heating up time

5:29 h:min

Standby power input

22.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

247 l

Average Climate

EN 12102-2

Sound power level indoor

53 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

135 %

COP

3.23

Heating up time

6:27 h:min

Standby power input

26.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

247 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

EKHHE200PCV37
Configure model
Model name
EKHHE200PCV37
Units
Indoor
Climate zone (for heating)
Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

53 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

162 %

COP

3.89

Heating up time

5:29 h:min

Standby power input

22.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

241 l

Average Climate

EN 12102-2

Sound power level indoor

53 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

135 %

COP

3.23

Heating up time

6:27 h:min

Standby power input

26.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

241 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed