Certificate holders

Subtype

Aquarea Split 9 kW STD (J Series)

Certificate Holder
Panasonic Marketing Europe GmbH
Hagenauer Strasse 43, Wiesbaden
65203 Wiesbaden
Germany
Registration number
011-1W0209
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquarea Split 9 kW STD (J Series)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,270 kg

Certification Date
08.01.2020
Testing basis
HP KEYMARK certification scheme rules V7
Generate PDF Export model CSV
  • Number of models 12

Models

WH-ADC0309J3E5 / WH-UD09JE5
Configure model
Model name
WH-ADC0309J3E5 / WH-UD09JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.62 kW

1.74 kW

Cooling capacity

7.60

7.60

EER

2.90

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

140 %

COP

3.50

Heating up time

1:22 h:min

Standby power input

30.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.47

Heating up time

1:22 h:min

Standby power input

37.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:22 h:min

Standby power input

31.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

WH-ADC0309J3E5B / WH-UD09JE5
Configure model
Model name
WH-ADC0309J3E5B / WH-UD09JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.62 kW

1.74 kW

Cooling capacity

7.60

7.60

EER

2.90

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

140 %

COP

3.50

Heating up time

1:22 h:min

Standby power input

30.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.47

Heating up time

1:22 h:min

Standby power input

37.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:22 h:min

Standby power input

31.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

WH-ADC0309J3E5AN / WH-UD09JE5
Configure model
Model name
WH-ADC0309J3E5AN / WH-UD09JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.62 kW

1.74 kW

Cooling capacity

7.60

7.60

EER

2.90

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

140 %

COP

3.50

Heating up time

1:22 h:min

Standby power input

30.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.47

Heating up time

1:22 h:min

Standby power input

37.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:22 h:min

Standby power input

31.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

WH-ADC0309J3E5UK / WH-UD09JE5
Configure model
Model name
WH-ADC0309J3E5UK / WH-UD09JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.62 kW

1.74 kW

Cooling capacity

7.60

7.60

EER

2.90

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

140 %

COP

3.50

Heating up time

1:22 h:min

Standby power input

30.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.47

Heating up time

1:22 h:min

Standby power input

37.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:22 h:min

Standby power input

31.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

WH-SDC0709J3E5 / WH-UD09JE5
Configure model
Model name
WH-SDC0709J3E5 / WH-UD09JE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.62 kW

1.74 kW

Cooling capacity

7.60

7.60

EER

2.90

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

WH-ADC0309J3E5 / WH-UD09JE5-1
Configure model
Model name
WH-ADC0309J3E5 / WH-UD09JE5-1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.02 kW

1.74 kW

Cooling capacity

8.20

7.60

EER

2.72

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

140 %

COP

3.50

Heating up time

1:22 h:min

Standby power input

30.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.47

Heating up time

1:22 h:min

Standby power input

37.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:22 h:min

Standby power input

31.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

WH-ADC0309J3E5B / WH-UD09JE5-1
Configure model
Model name
WH-ADC0309J3E5B / WH-UD09JE5-1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.02 kW

1.74 kW

Cooling capacity

8.20

7.60

EER

2.72

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

140 %

COP

3.50

Heating up time

1:22 h:min

Standby power input

30.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.47

Heating up time

1:22 h:min

Standby power input

37.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:22 h:min

Standby power input

31.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

WH-ADC0309J3E5AN / WH-UD09JE5-1
Configure model
Model name
WH-ADC0309J3E5AN / WH-UD09JE5-1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.02 kW

1.74 kW

Cooling capacity

8.20

7.60

EER

2.72

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

140 %

COP

3.50

Heating up time

1:22 h:min

Standby power input

30.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.47

Heating up time

1:22 h:min

Standby power input

37.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:22 h:min

Standby power input

31.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

WH-ADC0309J3E5UK / WH-UD09JE5-1
Configure model
Model name
WH-ADC0309J3E5UK / WH-UD09JE5-1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.02 kW

1.74 kW

Cooling capacity

8.20

7.60

EER

2.72

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

140 %

COP

3.50

Heating up time

1:22 h:min

Standby power input

30.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.47

Heating up time

1:22 h:min

Standby power input

37.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

3.00

Heating up time

1:22 h:min

Standby power input

31.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

WH-SDC0709J3E5 / WH-UD09JE5-1
Configure model
Model name
WH-SDC0709J3E5 / WH-UD09JE5-1
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.02 kW

1.74 kW

Cooling capacity

8.20

7.60

EER

2.72

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

WH-ADC0309J3E5C / WH-UD09JE5-1
Configure model
Model name
WH-ADC0309J3E5C / WH-UD09JE5-1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.02 kW

1.74 kW

Cooling capacity

8.20

7.60

EER

2.72

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:01 h:min

Standby power input

34.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

232 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98 %

COP

2.45

Heating up time

1:01 h:min

Standby power input

45.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.90

Heating up time

1:01 h:min

Standby power input

39.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

232 l

WH-ADC0309J3E5ANC / WH-UD09JE5-1
Configure model
Model name
WH-ADC0309J3E5ANC / WH-UD09JE5-1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.95 kW

El input

2.01 kW

3.22 kW

COP

4.48

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.02 kW

1.74 kW

Cooling capacity

8.20

7.60

EER

2.72

4.37

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.00 kW

kW

SEER

5.08

 

Pdc Tj = 35°C

7.00 kW

kW

EER Tj = 35°C

2.95

 

Pdc Tj = 30°C

5.16 kW

kW

EER Tj = 30°C

4.00

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

3.32 kW

kW

EER Tj = 25°C

5.91

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

1.47 kW

kW

EER Tj = 20°C

7.54

 

Cdc Tj = 20 °C

0.9

 

Poff

8 W

W

PTO

0 W

W

PSB

8 W

W

PCK

0 W

W

Annual energy consumption Qce

482 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

160 %

Prated

7.00 kW

6.00 kW

SCOP

5.75

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

6.10 kW

COP Tj = +2°C

2.80

2.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

4.50 kW

3.80 kW

COP Tj = +7°C

5.37

3.51

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

7.77

5.80

Cdh Tj = +12 °C

0.900

0.920

Pdh Tj = Tbiv

7.10 kW

6.10 kW

COP Tj = Tbiv

2.80

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.14

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1627 kWh

1971 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

116 %

Prated

7.00 kW

6.00 kW

SCOP

4.18

2.98

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.20 kW

3.60 kW

COP Tj = -7°C

3.41

2.41

Cdh Tj = -7 °C

0.960

0.970

Pdh Tj = +2°C

2.50 kW

2.20 kW

COP Tj = +2°C

5.39

3.75

Cdh Tj = +2 °C

0.900

0.920

Pdh Tj = +7°C

3.00 kW

2.80 kW

COP Tj = +7°C

6.69

5.01

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.24

6.67

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

5.70 kW

4.90 kW

COP Tj = Tbiv

2.44

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.82

1.08

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.30 kW

Annual energy consumption Qhe

4132 kWh

4967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.70

4.90

COP Tj = -15°C (if TOL<-20°C)

2.44

1.72

Cdh Tj = -15 °C

0.980

0.980

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

130 %

Prated

7.00 kW

7.00 kW

SCOP

4.90

3.32

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.20 kW

COP Tj = -7°C

2.80

1.86

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.80 kW

3.80 kW

COP Tj = +2°C

5.03

3.33

Cdh Tj = +2 °C

0.940

0.960

Pdh Tj = +7°C

3.00 kW

2.70 kW

COP Tj = +7°C

6.56

4.52

Cdh Tj = +7 °C

0.900

0.920

Pdh Tj = 12°C

3.40 kW

3.30 kW

COP Tj = 12°C

8.47

6.26

Cdh Tj = +12 °C

0.890

0.910

Pdh Tj = Tbiv

7.00 kW

6.20 kW

COP Tj = Tbiv

2.60

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.70

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

44 W

44 W

PSB

10 W

10 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.80 kW

Annual energy consumption Qhe

2949 kWh

4354 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

1:01 h:min

Standby power input

34.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

232 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

98 %

COP

2.45

Heating up time

1:01 h:min

Standby power input

45.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

116 %

COP

2.90

Heating up time

1:01 h:min

Standby power input

39.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

232 l