Certificate holders

Subtype

Aquarea Split 3-5 kW STD (J Series)

Certificate Holder
Panasonic Marketing Europe GmbH
Hagenauer Strasse 43, Wiesbaden
65203 Wiesbaden
Germany
Registration number
011-1W0207
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquarea Split 3-5 kW STD (J Series)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,900 kg

Certification Date
08.01.2020
Testing basis
HP KEYMARK certification scheme rules V7
Generate PDF Export model CSV
  • Number of models 14

Models

WH-ADC0309J3E5 / WH-UD03JE5
Configure model
Model name
WH-ADC0309J3E5 / WH-UD03JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.20 kW

3.20 kW

El input

0.60 kW

1.14 kW

COP

5.33

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.91 kW

0.68 kW

Cooling capacity

3.20

3.20

EER

3.52

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

3.00 kW

kW

SEER

6.29

 

Pdc Tj = 35°C

3.00 kW

kW

EER Tj = 35°C

3.95

 

Pdc Tj = 30°C

2.21 kW

kW

EER Tj = 30°C

5.37

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.42 kW

kW

EER Tj = 25°C

7.44

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.63 kW

kW

EER Tj = 20°C

8.93

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

167 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.940

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

4.00 kW

3.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

2.60 kW

COP Tj = -7°C

2.80

2.18

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.00 kW

1.60 kW

COP Tj = +2°C

5.14

3.42

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

1.40 kW

1.10 kW

COP Tj = +7°C

6.80

4.43

Cdh Tj = +7 °C

0.870

0.900

Pdh Tj = 12°C

1.60 kW

1.40 kW

COP Tj = 12°C

9.50

6.97

Cdh Tj = +12 °C

0.840

0.570

Pdh Tj = Tbiv

4.00 kW

2.90 kW

COP Tj = Tbiv

2.60

1.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

2.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.66

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1631 kWh

1788 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

155 %

COP

3.88

Heating up time

1:28 h:min

Standby power input

27.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:28 h:min

Standby power input

33.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5 / WH-UD05JE5
Configure model
Model name
WH-ADC0309J3E5 / WH-UD05JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

1.00 kW

1.84 kW

COP

5.00

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.50 kW

1.12 kW

Cooling capacity

4.50

4.80

EER

3.00

4.29

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

kW

SEER

6.20

 

Pdc Tj = 35°C

4.00 kW

kW

EER Tj = 35°C

3.47

 

Pdc Tj = 30°C

2.95 kW

kW

EER Tj = 30°C

5.12

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.89 kW

kW

EER Tj = 25°C

7.31

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.84 kW

kW

EER Tj = 20°C

9.26

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

226 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.860

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

5.00 kW

4.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.20 kW

3.40 kW

COP Tj = -7°C

2.66

1.93

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.50 kW

2.10 kW

COP Tj = +2°C

5.15

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.70 kW

1.40 kW

COP Tj = +7°C

6.95

4.60

Cdh Tj = +7 °C

0.890

0.910

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.45

6.90

Cdh Tj = +12 °C

0.850

0.880

Pdh Tj = Tbiv

4.70 kW

3.80 kW

COP Tj = Tbiv

2.50

1.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.55

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.20 kW

Annual energy consumption Qhe

2038 kWh

2385 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

155 %

COP

3.88

Heating up time

1:28 h:min

Standby power input

27.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:28 h:min

Standby power input

33.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5B / WH-UD03JE5
Configure model
Model name
WH-ADC0309J3E5B / WH-UD03JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.20 kW

3.20 kW

El input

0.60 kW

1.14 kW

COP

5.33

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.91 kW

0.68 kW

Cooling capacity

3.20

3.20

EER

3.52

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

3.00 kW

kW

SEER

6.29

 

Pdc Tj = 35°C

3.00 kW

kW

EER Tj = 35°C

3.95

 

Pdc Tj = 30°C

2.21 kW

kW

EER Tj = 30°C

5.37

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.42 kW

kW

EER Tj = 25°C

7.44

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.63 kW

kW

EER Tj = 20°C

8.93

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

167 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.940

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

4.00 kW

3.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

2.60 kW

COP Tj = -7°C

2.80

2.18

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.00 kW

1.60 kW

COP Tj = +2°C

5.14

3.42

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

1.40 kW

1.10 kW

COP Tj = +7°C

6.80

4.43

Cdh Tj = +7 °C

0.870

0.900

Pdh Tj = 12°C

1.60 kW

1.40 kW

COP Tj = 12°C

9.50

6.97

Cdh Tj = +12 °C

0.840

0.570

Pdh Tj = Tbiv

4.00 kW

2.90 kW

COP Tj = Tbiv

2.60

1.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

2.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.66

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1631 kWh

1788 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

155 %

COP

3.88

Heating up time

1:28 h:min

Standby power input

27.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:28 h:min

Standby power input

33.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5AN / WH-UD03JE5
Configure model
Model name
WH-ADC0309J3E5AN / WH-UD03JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.20 kW

3.20 kW

El input

0.60 kW

1.14 kW

COP

5.33

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.91 kW

0.68 kW

Cooling capacity

3.20

3.20

EER

3.52

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

3.00 kW

kW

SEER

6.29

 

Pdc Tj = 35°C

3.00 kW

kW

EER Tj = 35°C

3.95

 

Pdc Tj = 30°C

2.21 kW

kW

EER Tj = 30°C

5.37

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.42 kW

kW

EER Tj = 25°C

7.44

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.63 kW

kW

EER Tj = 20°C

8.93

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

167 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.940

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

4.00 kW

3.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

2.60 kW

COP Tj = -7°C

2.80

2.18

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.00 kW

1.60 kW

COP Tj = +2°C

5.14

3.42

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

1.40 kW

1.10 kW

COP Tj = +7°C

6.80

4.43

Cdh Tj = +7 °C

0.870

0.900

Pdh Tj = 12°C

1.60 kW

1.40 kW

COP Tj = 12°C

9.50

6.97

Cdh Tj = +12 °C

0.840

0.570

Pdh Tj = Tbiv

4.00 kW

2.90 kW

COP Tj = Tbiv

2.60

1.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

2.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.66

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1631 kWh

1788 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

155 %

COP

3.88

Heating up time

1:28 h:min

Standby power input

27.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:28 h:min

Standby power input

33.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5UK / WH-UD03JE5
Configure model
Model name
WH-ADC0309J3E5UK / WH-UD03JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.20 kW

3.20 kW

El input

0.60 kW

1.14 kW

COP

5.33

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.91 kW

0.68 kW

Cooling capacity

3.20

3.20

EER

3.52

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

3.00 kW

kW

SEER

6.29

 

Pdc Tj = 35°C

3.00 kW

kW

EER Tj = 35°C

3.95

 

Pdc Tj = 30°C

2.21 kW

kW

EER Tj = 30°C

5.37

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.42 kW

kW

EER Tj = 25°C

7.44

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.63 kW

kW

EER Tj = 20°C

8.93

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

167 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.940

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

4.00 kW

3.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

2.60 kW

COP Tj = -7°C

2.80

2.18

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.00 kW

1.60 kW

COP Tj = +2°C

5.14

3.42

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

1.40 kW

1.10 kW

COP Tj = +7°C

6.80

4.43

Cdh Tj = +7 °C

0.870

0.900

Pdh Tj = 12°C

1.60 kW

1.40 kW

COP Tj = 12°C

9.50

6.97

Cdh Tj = +12 °C

0.840

0.570

Pdh Tj = Tbiv

4.00 kW

2.90 kW

COP Tj = Tbiv

2.60

1.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

2.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.66

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1631 kWh

1788 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

155 %

COP

3.88

Heating up time

1:28 h:min

Standby power input

27.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:28 h:min

Standby power input

33.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5B / WH-UD05JE5
Configure model
Model name
WH-ADC0309J3E5B / WH-UD05JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

1.00 kW

1.84 kW

COP

5.00

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.50 kW

1.12 kW

Cooling capacity

4.50

4.80

EER

3.00

4.29

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

kW

SEER

6.20

 

Pdc Tj = 35°C

4.00 kW

kW

EER Tj = 35°C

3.47

 

Pdc Tj = 30°C

2.95 kW

kW

EER Tj = 30°C

5.12

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.89 kW

kW

EER Tj = 25°C

7.31

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.84 kW

kW

EER Tj = 20°C

9.26

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

226 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.860

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

5.00 kW

4.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.20 kW

3.40 kW

COP Tj = -7°C

2.66

1.93

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.50 kW

2.10 kW

COP Tj = +2°C

5.15

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.70 kW

1.40 kW

COP Tj = +7°C

6.95

4.60

Cdh Tj = +7 °C

0.890

0.910

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.45

6.90

Cdh Tj = +12 °C

0.850

0.880

Pdh Tj = Tbiv

4.70 kW

3.80 kW

COP Tj = Tbiv

2.50

1.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.55

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.20 kW

Annual energy consumption Qhe

2038 kWh

2385 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

155 %

COP

3.88

Heating up time

1:28 h:min

Standby power input

27.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:28 h:min

Standby power input

33.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5AN / WH-UD05JE5
Configure model
Model name
WH-ADC0309J3E5AN / WH-UD05JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

1.00 kW

1.84 kW

COP

5.00

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.50 kW

1.12 kW

Cooling capacity

4.50

4.80

EER

3.00

4.29

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

kW

SEER

6.20

 

Pdc Tj = 35°C

4.00 kW

kW

EER Tj = 35°C

3.47

 

Pdc Tj = 30°C

2.95 kW

kW

EER Tj = 30°C

5.12

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.89 kW

kW

EER Tj = 25°C

7.31

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.84 kW

kW

EER Tj = 20°C

9.26

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

226 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.860

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

5.00 kW

4.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.20 kW

3.40 kW

COP Tj = -7°C

2.66

1.93

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.50 kW

2.10 kW

COP Tj = +2°C

5.15

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.70 kW

1.40 kW

COP Tj = +7°C

6.95

4.60

Cdh Tj = +7 °C

0.890

0.910

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.45

6.90

Cdh Tj = +12 °C

0.850

0.880

Pdh Tj = Tbiv

4.70 kW

3.80 kW

COP Tj = Tbiv

2.50

1.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.55

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.20 kW

Annual energy consumption Qhe

2038 kWh

2385 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

155 %

COP

3.88

Heating up time

1:28 h:min

Standby power input

27.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:28 h:min

Standby power input

33.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5UK / WH-UD05JE5
Configure model
Model name
WH-ADC0309J3E5UK / WH-UD05JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

1.00 kW

1.84 kW

COP

5.00

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.50 kW

1.12 kW

Cooling capacity

4.50

4.80

EER

3.00

4.29

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

kW

SEER

6.20

 

Pdc Tj = 35°C

4.00 kW

kW

EER Tj = 35°C

3.47

 

Pdc Tj = 30°C

2.95 kW

kW

EER Tj = 30°C

5.12

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.89 kW

kW

EER Tj = 25°C

7.31

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.84 kW

kW

EER Tj = 20°C

9.26

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

226 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.860

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

5.00 kW

4.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.20 kW

3.40 kW

COP Tj = -7°C

2.66

1.93

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.50 kW

2.10 kW

COP Tj = +2°C

5.15

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.70 kW

1.40 kW

COP Tj = +7°C

6.95

4.60

Cdh Tj = +7 °C

0.890

0.910

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.45

6.90

Cdh Tj = +12 °C

0.850

0.880

Pdh Tj = Tbiv

4.70 kW

3.80 kW

COP Tj = Tbiv

2.50

1.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.55

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.20 kW

Annual energy consumption Qhe

2038 kWh

2385 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

155 %

COP

3.88

Heating up time

1:28 h:min

Standby power input

27.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:28 h:min

Standby power input

33.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

239 l

WH-SDC0305J3E5 / WH-UD03JE5
Configure model
Model name
WH-SDC0305J3E5 / WH-UD03JE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.20 kW

3.20 kW

El input

0.60 kW

1.14 kW

COP

5.33

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.91 kW

0.68 kW

Cooling capacity

3.20

3.20

EER

3.52

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

3.00 kW

kW

SEER

6.29

 

Pdc Tj = 35°C

3.00 kW

kW

EER Tj = 35°C

3.95

 

Pdc Tj = 30°C

2.21 kW

kW

EER Tj = 30°C

5.37

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.42 kW

kW

EER Tj = 25°C

7.44

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.63 kW

kW

EER Tj = 20°C

8.93

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

167 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.940

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

4.00 kW

3.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

2.60 kW

COP Tj = -7°C

2.80

2.18

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.00 kW

1.60 kW

COP Tj = +2°C

5.14

3.42

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

1.40 kW

1.10 kW

COP Tj = +7°C

6.80

4.43

Cdh Tj = +7 °C

0.870

0.900

Pdh Tj = 12°C

1.60 kW

1.40 kW

COP Tj = 12°C

9.50

6.97

Cdh Tj = +12 °C

0.840

0.570

Pdh Tj = Tbiv

4.00 kW

2.90 kW

COP Tj = Tbiv

2.60

1.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

2.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.66

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1631 kWh

1788 kWh

WH-SDC0305J3E5 / WH-UD05JE5
Configure model
Model name
WH-SDC0305J3E5 / WH-UD05JE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

1.00 kW

1.84 kW

COP

5.00

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.50 kW

1.12 kW

Cooling capacity

4.50

4.80

EER

3.00

4.29

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

kW

SEER

6.20

 

Pdc Tj = 35°C

4.00 kW

kW

EER Tj = 35°C

3.47

 

Pdc Tj = 30°C

2.95 kW

kW

EER Tj = 30°C

5.12

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.89 kW

kW

EER Tj = 25°C

7.31

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.84 kW

kW

EER Tj = 20°C

9.26

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

226 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.860

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

5.00 kW

4.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.20 kW

3.40 kW

COP Tj = -7°C

2.66

1.93

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.50 kW

2.10 kW

COP Tj = +2°C

5.15

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.70 kW

1.40 kW

COP Tj = +7°C

6.95

4.60

Cdh Tj = +7 °C

0.890

0.910

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.45

6.90

Cdh Tj = +12 °C

0.850

0.880

Pdh Tj = Tbiv

4.70 kW

3.80 kW

COP Tj = Tbiv

2.50

1.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.55

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.20 kW

Annual energy consumption Qhe

2038 kWh

2385 kWh

WH-ADC0309J3E5C / WH-UD03JE5
Configure model
Model name
WH-ADC0309J3E5C / WH-UD03JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.20 kW

3.20 kW

El input

0.60 kW

1.14 kW

COP

5.33

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.91 kW

0.68 kW

Cooling capacity

3.20

3.20

EER

3.52

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

3.00 kW

kW

SEER

6.29

 

Pdc Tj = 35°C

3.00 kW

kW

EER Tj = 35°C

3.95

 

Pdc Tj = 30°C

2.21 kW

kW

EER Tj = 30°C

5.37

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.42 kW

kW

EER Tj = 25°C

7.44

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.63 kW

kW

EER Tj = 20°C

8.93

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

167 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.940

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

4.00 kW

3.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

2.60 kW

COP Tj = -7°C

2.80

2.18

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.00 kW

1.60 kW

COP Tj = +2°C

5.14

3.42

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

1.40 kW

1.10 kW

COP Tj = +7°C

6.80

4.43

Cdh Tj = +7 °C

0.870

0.900

Pdh Tj = 12°C

1.60 kW

1.40 kW

COP Tj = 12°C

9.50

6.97

Cdh Tj = +12 °C

0.840

0.570

Pdh Tj = Tbiv

4.00 kW

2.90 kW

COP Tj = Tbiv

2.60

1.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

2.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.66

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1631 kWh

1788 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

154 %

COP

3.86

Heating up time

1:32 h:min

Standby power input

28.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:32 h:min

Standby power input

34.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

129 %

COP

3.23

Heating up time

1:32 h:min

Standby power input

31.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5ANC / WH-UD03JE5
Configure model
Model name
WH-ADC0309J3E5ANC / WH-UD03JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.20 kW

3.20 kW

El input

0.60 kW

1.14 kW

COP

5.33

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.91 kW

0.68 kW

Cooling capacity

3.20

3.20

EER

3.52

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

3.00 kW

kW

SEER

6.29

 

Pdc Tj = 35°C

3.00 kW

kW

EER Tj = 35°C

3.95

 

Pdc Tj = 30°C

2.21 kW

kW

EER Tj = 30°C

5.37

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.42 kW

kW

EER Tj = 25°C

7.44

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.63 kW

kW

EER Tj = 20°C

8.93

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

167 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.940

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

4.00 kW

3.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

2.60 kW

COP Tj = -7°C

2.80

2.18

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.00 kW

1.60 kW

COP Tj = +2°C

5.14

3.42

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

1.40 kW

1.10 kW

COP Tj = +7°C

6.80

4.43

Cdh Tj = +7 °C

0.870

0.900

Pdh Tj = 12°C

1.60 kW

1.40 kW

COP Tj = 12°C

9.50

6.97

Cdh Tj = +12 °C

0.840

0.570

Pdh Tj = Tbiv

4.00 kW

2.90 kW

COP Tj = Tbiv

2.60

1.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

2.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.66

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1631 kWh

1788 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

154 %

COP

3.86

Heating up time

1:32 h:min

Standby power input

28.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:32 h:min

Standby power input

34.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

129 %

COP

3.23

Heating up time

1:32 h:min

Standby power input

31.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5C / WH-UD05JE5
Configure model
Model name
WH-ADC0309J3E5C / WH-UD05JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

1.00 kW

1.84 kW

COP

5.00

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.50 kW

1.12 kW

Cooling capacity

4.50

4.80

EER

3.00

4.29

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

kW

SEER

6.20

 

Pdc Tj = 35°C

4.00 kW

kW

EER Tj = 35°C

3.47

 

Pdc Tj = 30°C

2.95 kW

kW

EER Tj = 30°C

5.12

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.89 kW

kW

EER Tj = 25°C

7.31

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.84 kW

kW

EER Tj = 20°C

9.26

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

226 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.860

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

5.00 kW

4.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.20 kW

3.40 kW

COP Tj = -7°C

2.66

1.93

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.50 kW

2.10 kW

COP Tj = +2°C

5.15

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.70 kW

1.40 kW

COP Tj = +7°C

6.95

4.60

Cdh Tj = +7 °C

0.890

0.910

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.45

6.90

Cdh Tj = +12 °C

0.850

0.880

Pdh Tj = Tbiv

4.70 kW

3.80 kW

COP Tj = Tbiv

2.50

1.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.55

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.20 kW

Annual energy consumption Qhe

2038 kWh

2385 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

154 %

COP

3.86

Heating up time

1:32 h:min

Standby power input

28.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:32 h:min

Standby power input

34.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

129 %

COP

3.23

Heating up time

1:32 h:min

Standby power input

31.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

WH-ADC0309J3E5ANC / WH-UD05JE5
Configure model
Model name
WH-ADC0309J3E5ANC / WH-UD05JE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.00 kW

5.00 kW

El input

1.00 kW

1.84 kW

COP

5.00

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.50 kW

1.12 kW

Cooling capacity

4.50

4.80

EER

3.00

4.29

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

kW

SEER

6.20

 

Pdc Tj = 35°C

4.00 kW

kW

EER Tj = 35°C

3.47

 

Pdc Tj = 30°C

2.95 kW

kW

EER Tj = 30°C

5.12

 

Cdc Tj = 30 °C

0.9

 

Pdc Tj = 25°C

1.89 kW

kW

EER Tj = 25°C

7.31

 

Cdc Tj = 25 °C

0.9

 

Pdc Tj = 20°C

0.84 kW

kW

EER Tj = 20°C

9.26

 

Cdc Tj = 20 °C

0.9

 

Poff

5 W

W

PTO

0 W

W

PSB

5 W

W

PCK

0 W

W

Annual energy consumption Qce

226 kWh

kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

245 %

165 %

Prated

4.00 kW

4.00 kW

SCOP

6.20

4.20

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.00 kW

3.90 kW

COP Tj = +2°C

3.15

1.80

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.60 kW

2.50 kW

COP Tj = +7°C

5.61

3.55

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

1.50 kW

1.40 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.860

0.890

Pdh Tj = Tbiv

4.00 kW

3.90 kW

COP Tj = Tbiv

3.15

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

1.80

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

862 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

110 %

Prated

3.00 kW

2.00 kW

SCOP

4.00

2.83

Tbiv

-20 °C

-20 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.80 kW

1.20 kW

COP Tj = -7°C

3.26

2.16

Cdh Tj = -7 °C

0.950

0.950

Pdh Tj = +2°C

1.80 kW

1.40 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.920

0.930

Pdh Tj = +7°C

1.30 kW

1.20 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.860

0.890

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.00

7.60

Cdh Tj = +12 °C

0.850

0.870

Pdh Tj = Tbiv

2.80 kW

1.80 kW

COP Tj = Tbiv

1.80

1.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.00 kW

2.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.81

1.05

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.00 kW

Annual energy consumption Qhe

1848 kWh

1740 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.40

1.70

COP Tj = -15°C (if TOL<-20°C)

2.29

1.76

Cdh Tj = -15 °C

0.980

0.970

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

5.00 kW

4.00 kW

SCOP

5.07

3.47

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.20 kW

3.40 kW

COP Tj = -7°C

2.66

1.93

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.50 kW

2.10 kW

COP Tj = +2°C

5.15

3.48

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

1.70 kW

1.40 kW

COP Tj = +7°C

6.95

4.60

Cdh Tj = +7 °C

0.890

0.910

Pdh Tj = 12°C

1.60 kW

1.50 kW

COP Tj = 12°C

9.45

6.90

Cdh Tj = +12 °C

0.850

0.880

Pdh Tj = Tbiv

4.70 kW

3.80 kW

COP Tj = Tbiv

2.50

1.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.70 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.55

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

26 W

26 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.20 kW

Annual energy consumption Qhe

2038 kWh

2385 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

154 %

COP

3.86

Heating up time

1:32 h:min

Standby power input

28.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.48

Heating up time

1:32 h:min

Standby power input

34.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

129 %

COP

3.23

Heating up time

1:32 h:min

Standby power input

31.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

239 l