Certificate holders

Subtype

Samsung EHS R32 Split 9kW (wall-mounted hydro unit)

Certificate Holder
Samsung Electronics Air Conditioner Europe B.V.
Evert van de Beekstraat 310
1118 CX Schiphol
Netherlands
Registration number
011-1W0456
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Samsung EHS R32 Split 9kW (wall-mounted hydro unit)
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,400 kg

Certification Date
26.01.2021
Testing basis
HP KEYMARK certification scheme rules V7
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AE090RXEDEG/EU & AE090RNYDEG/EU
Configure model
Model name
AE090RXEDEG/EU & AE090RNYDEG/EU
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.00 kW

El input

1.87 kW

2.73 kW

COP

4.81

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

127 %

Prated

9.00 kW

8.00 kW

SCOP

4.45

3.24

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.10 kW

COP Tj = -7°C

2.64

1.76

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.60 kW

4.30 kW

COP Tj = +2°C

4.17

3.23

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.90 kW

2.80 kW

COP Tj = +7°C

6.53

4.62

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.70 kW

2.60 kW

COP Tj = 12°C

8.87

5.88

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.50 kW

7.10 kW

COP Tj = Tbiv

2.64

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.32

1.35

WTOL

65 °C

65 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

3.10 kW

Annual energy consumption Qhe

3949 kWh

5103 kWh

AE090RXEDGG/EU & AE090RNYDGG/EU
Configure model
Model name
AE090RXEDGG/EU & AE090RNYDGG/EU
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.00 kW

El input

1.87 kW

2.73 kW

COP

4.81

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

127 %

Prated

9.00 kW

8.00 kW

SCOP

4.45

3.24

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.50 kW

7.10 kW

COP Tj = -7°C

2.64

1.76

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.60 kW

4.30 kW

COP Tj = +2°C

4.17

3.23

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.90 kW

2.80 kW

COP Tj = +7°C

6.53

4.62

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.70 kW

2.60 kW

COP Tj = 12°C

8.87

5.88

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.50 kW

7.10 kW

COP Tj = Tbiv

2.64

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.32

1.35

WTOL

65 °C

65 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

3.10 kW

Annual energy consumption Qhe

3949 kWh

5103 kWh