1,850 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.42 kW
12.19 kW
El input
2.14 kW
4.00 kW
COP
4.87
3.05
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
169 %
Prated
15.88 kW
14.68 kW
SCOP
5.79
4.42
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
15.88 kW
14.68 kW
COP Tj = +2°C
4.59
3.11
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.21 kW
9.44 kW
COP Tj = +7°C
5.56
3.98
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
4.54 kW
4.20 kW
COP Tj = 12°C
6.37
5.21
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.88 kW
14.68 kW
COP Tj = Tbiv
4.59
3.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.88 kW
14.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
3.11
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3666 kWh
4441 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
230 %
174 %
Prated
15.88 kW
14.68 kW
SCOP
5.96
4.54
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.61 kW
8.89 kW
COP Tj = -7°C
5.79
4.21
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.85 kW
5.41 kW
COP Tj = +2°C
6.40
4.98
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.28 kW
4.20 kW
COP Tj = +7°C
6.13
5.15
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.23 kW
4.22 kW
COP Tj = 12°C
5.83
5.21
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.88 kW
14.68 kW
COP Tj = Tbiv
4.59
3.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.88 kW
14.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
3.11
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6574 kWh
7969 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
222 %
168 %
Prated
15.88 kW
14.68 kW
SCOP
5.76
4.40
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.05 kW
12.99 kW
COP Tj = -7°C
4.89
3.35
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
8.55 kW
7.91 kW
COP Tj = +2°C
5.86
4.48
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.50 kW
5.08 kW
COP Tj = +7°C
6.38
5.07
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.26 kW
4.18 kW
COP Tj = 12°C
6.02
5.08
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.88 kW
14.68 kW
COP Tj = Tbiv
4.59
3.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.88 kW
14.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
3.11
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5700 kWh
6893 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.68 kW
18.11 kW
El input
1.88 kW
4.60 kW
COP
6.73
3.94
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
301 %
219 %
Prated
12.68 kW
18.11 kW
SCOP
7.72
5.66
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.68 kW
18.11 kW
COP Tj = +2°C
6.73
3.94
Cdh Tj = +2 °C
0.99
1.00
Pdh Tj = +7°C
8.15 kW
11.64 kW
COP Tj = +7°C
7.78
5.15
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.79 kW
5.17 kW
COP Tj = 12°C
8.34
6.65
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.68 kW
18.11 kW
COP Tj = Tbiv
6.73
3.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.68 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.73
3.94
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2195 kWh
4271 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
312 %
227 %
Prated
12.68 kW
18.11 kW
SCOP
8.00
5.88
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.68 kW
10.96 kW
COP Tj = -7°C
8.04
5.48
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
5.79 kW
6.67 kW
COP Tj = +2°C
8.32
6.44
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.80 kW
5.61 kW
COP Tj = +7°C
8.46
6.66
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
5.79 kW
5.64 kW
COP Tj = 12°C
8.35
6.80
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.68 kW
18.11 kW
COP Tj = Tbiv
6.73
3.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.68 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.73
3.94
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3908 kWh
7589 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
303 %
220 %
Prated
12.68 kW
18.11 kW
SCOP
7.78
5.70
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.22 kW
16.02 kW
COP Tj = -7°C
7.04
4.25
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
6.83 kW
9.75 kW
COP Tj = +2°C
8.03
5.83
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.79 kW
6.27 kW
COP Tj = +7°C
8.26
6.57
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
5.80 kW
5.61 kW
COP Tj = 12°C
8.49
6.63
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.68 kW
18.11 kW
COP Tj = Tbiv
6.73
3.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.68 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.73
3.94
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3370 kWh
6569 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.42 kW
12.19 kW
El input
2.14 kW
4.00 kW
COP
4.87
3.05
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
169 %
Prated
15.88 kW
14.68 kW
SCOP
5.79
4.42
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
15.88 kW
14.68 kW
COP Tj = +2°C
4.59
3.11
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.21 kW
9.44 kW
COP Tj = +7°C
5.56
3.98
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
4.54 kW
4.20 kW
COP Tj = 12°C
6.37
5.21
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.88 kW
14.68 kW
COP Tj = Tbiv
4.59
3.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.88 kW
14.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
3.11
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3666 kWh
4441 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
230 %
174 %
Prated
15.88 kW
14.68 kW
SCOP
5.96
4.54
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.61 kW
8.89 kW
COP Tj = -7°C
5.79
4.21
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.85 kW
5.41 kW
COP Tj = +2°C
6.40
4.98
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.28 kW
4.20 kW
COP Tj = +7°C
6.13
5.15
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.23 kW
4.22 kW
COP Tj = 12°C
5.83
5.21
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.88 kW
14.68 kW
COP Tj = Tbiv
4.59
3.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.88 kW
14.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
3.11
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6574 kWh
7969 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
38 dB(A)
38 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
222 %
168 %
Prated
15.88 kW
14.68 kW
SCOP
5.76
4.40
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.05 kW
12.99 kW
COP Tj = -7°C
4.89
3.35
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
8.55 kW
7.91 kW
COP Tj = +2°C
5.86
4.48
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.50 kW
5.08 kW
COP Tj = +7°C
6.38
5.07
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.26 kW
4.18 kW
COP Tj = 12°C
6.02
5.08
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.88 kW
14.68 kW
COP Tj = Tbiv
4.59
3.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.88 kW
14.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
3.11
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5700 kWh
6893 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.68 kW
18.11 kW
El input
1.88 kW
4.60 kW
COP
6.73
3.94
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
301 %
219 %
Prated
12.68 kW
18.11 kW
SCOP
7.72
5.66
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.68 kW
18.11 kW
COP Tj = +2°C
6.73
3.94
Cdh Tj = +2 °C
0.99
1.00
Pdh Tj = +7°C
8.15 kW
11.64 kW
COP Tj = +7°C
7.78
5.15
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.79 kW
5.17 kW
COP Tj = 12°C
8.34
6.65
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.68 kW
18.11 kW
COP Tj = Tbiv
6.73
3.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.68 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.73
3.94
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2195 kWh
4271 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
312 %
227 %
Prated
12.68 kW
18.11 kW
SCOP
8.00
5.88
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.68 kW
10.96 kW
COP Tj = -7°C
8.04
5.48
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
5.79 kW
6.67 kW
COP Tj = +2°C
8.32
6.44
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.80 kW
5.61 kW
COP Tj = +7°C
8.46
6.66
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
5.79 kW
5.64 kW
COP Tj = 12°C
8.35
6.80
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.68 kW
18.11 kW
COP Tj = Tbiv
6.73
3.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.68 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.73
3.94
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3908 kWh
7589 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
303 %
220 %
Prated
12.68 kW
18.11 kW
SCOP
7.78
5.70
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.22 kW
16.02 kW
COP Tj = -7°C
7.04
4.25
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
6.83 kW
9.75 kW
COP Tj = +2°C
8.03
5.83
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.79 kW
6.27 kW
COP Tj = +7°C
8.26
6.57
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
5.80 kW
5.61 kW
COP Tj = 12°C
8.49
6.63
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.68 kW
18.11 kW
COP Tj = Tbiv
6.73
3.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.68 kW
18.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.73
3.94
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3370 kWh
6569 kWh