1,300 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
8.42 kW
El input
1.09 kW
2.84 kW
COP
4.78
2.96
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
222 %
164 %
Prated
11.52 kW
10.57 kW
SCOP
5.76
4.29
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.52 kW
10.57 kW
COP Tj = +2°C
4.39
2.96
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.41 kW
6.79 kW
COP Tj = +7°C
5.38
3.81
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
3.29 kW
3.02 kW
COP Tj = 12°C
6.47
5.12
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2674 kWh
3290 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
226 %
168 %
Prated
11.52 kW
10.57 kW
SCOP
5.85
4.39
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.97 kW
6.40 kW
COP Tj = -7°C
5.69
4.02
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.24 kW
3.89 kW
COP Tj = +2°C
6.38
4.92
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.73 kW
2.50 kW
COP Tj = +7°C
5.79
4.88
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
2.78 kW
2.74 kW
COP Tj = 12°C
5.51
4.74
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4856 kWh
5928 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
11.52 kW
10.57 kW
SCOP
5.67
4.25
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.19 kW
9.35 kW
COP Tj = -7°C
4.66
3.23
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
6.20 kW
5.69 kW
COP Tj = +2°C
5.81
4.27
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.99 kW
3.66 kW
COP Tj = +7°C
6.39
5.06
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.77 kW
2.73 kW
COP Tj = 12°C
5.67
4.67
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4195 kWh
5134 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.24 kW
14.24 kW
El input
2.01 kW
3.84 kW
COP
6.08
3.71
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
295 %
214 %
Prated
12.24 kW
14.24 kW
SCOP
7.57
5.56
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.24 kW
14.24 kW
COP Tj = +2°C
6.08
3.71
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.87 kW
9.16 kW
COP Tj = +7°C
7.15
4.96
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
3.50 kW
4.07 kW
COP Tj = 12°C
8.40
6.62
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2161 kWh
3425 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
300 %
223 %
Prated
12.24 kW
14.24 kW
SCOP
7.70
5.77
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.41 kW
8.62 kW
COP Tj = -7°C
7.43
5.28
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
4.51 kW
5.25 kW
COP Tj = +2°C
8.14
6.31
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.71 kW
3.37 kW
COP Tj = +7°C
8.35
7.00
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
3.68 kW
3.66 kW
COP Tj = 12°C
7.96
6.72
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3917 kWh
6086 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
292 %
213 %
Prated
12.24 kW
14.24 kW
SCOP
7.51
5.52
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.83 kW
12.60 kW
COP Tj = -7°C
6.35
4.09
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
6.59 kW
7.67 kW
COP Tj = +2°C
7.52
5.56
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.24 kW
4.93 kW
COP Tj = +7°C
8.40
6.49
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
3.70 kW
3.65 kW
COP Tj = 12°C
8.22
6.57
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3369 kWh
5331 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
8.42 kW
El input
1.09 kW
2.84 kW
COP
4.78
2.96
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
222 %
164 %
Prated
11.52 kW
10.57 kW
SCOP
5.76
4.29
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.52 kW
10.57 kW
COP Tj = +2°C
4.39
2.96
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.41 kW
6.79 kW
COP Tj = +7°C
5.38
3.81
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
3.29 kW
3.02 kW
COP Tj = 12°C
6.47
5.12
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2674 kWh
3290 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
226 %
168 %
Prated
11.52 kW
10.57 kW
SCOP
5.85
4.39
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.97 kW
6.40 kW
COP Tj = -7°C
5.69
4.02
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.24 kW
3.89 kW
COP Tj = +2°C
6.38
4.92
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.73 kW
2.50 kW
COP Tj = +7°C
5.79
4.88
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
2.78 kW
2.74 kW
COP Tj = 12°C
5.51
4.74
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4856 kWh
5928 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
11.52 kW
10.57 kW
SCOP
5.67
4.25
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.19 kW
9.35 kW
COP Tj = -7°C
4.66
3.23
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
6.20 kW
5.69 kW
COP Tj = +2°C
5.81
4.27
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.99 kW
3.66 kW
COP Tj = +7°C
6.39
5.06
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.77 kW
2.73 kW
COP Tj = 12°C
5.67
4.67
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4195 kWh
5134 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.24 kW
14.24 kW
El input
2.01 kW
3.84 kW
COP
6.08
3.71
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
295 %
214 %
Prated
12.24 kW
14.24 kW
SCOP
7.57
5.56
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.24 kW
14.24 kW
COP Tj = +2°C
6.08
3.71
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.87 kW
9.16 kW
COP Tj = +7°C
7.15
4.96
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
3.50 kW
4.07 kW
COP Tj = 12°C
8.40
6.62
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2161 kWh
3425 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
300 %
223 %
Prated
12.24 kW
14.24 kW
SCOP
7.70
5.77
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.41 kW
8.62 kW
COP Tj = -7°C
7.43
5.28
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
4.51 kW
5.25 kW
COP Tj = +2°C
8.14
6.31
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.71 kW
3.37 kW
COP Tj = +7°C
8.35
7.00
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
3.68 kW
3.66 kW
COP Tj = 12°C
7.96
6.72
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3917 kWh
6086 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
292 %
213 %
Prated
12.24 kW
14.24 kW
SCOP
7.51
5.52
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.83 kW
12.60 kW
COP Tj = -7°C
6.35
4.09
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
6.59 kW
7.67 kW
COP Tj = +2°C
7.52
5.56
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.24 kW
4.93 kW
COP Tj = +7°C
8.40
6.49
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
3.70 kW
3.65 kW
COP Tj = 12°C
8.22
6.57
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3369 kWh
5331 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
8.42 kW
El input
1.09 kW
2.84 kW
COP
4.78
2.96
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
222 %
164 %
Prated
11.52 kW
10.57 kW
SCOP
5.76
4.29
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.52 kW
10.57 kW
COP Tj = +2°C
4.39
2.96
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.41 kW
6.79 kW
COP Tj = +7°C
5.38
3.81
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
3.29 kW
3.02 kW
COP Tj = 12°C
6.47
5.12
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2674 kWh
3290 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
226 %
168 %
Prated
11.52 kW
10.57 kW
SCOP
5.85
4.39
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.97 kW
6.40 kW
COP Tj = -7°C
5.69
4.02
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.24 kW
3.89 kW
COP Tj = +2°C
6.38
4.92
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.73 kW
2.50 kW
COP Tj = +7°C
5.79
4.88
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
2.78 kW
2.74 kW
COP Tj = 12°C
5.51
4.74
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4856 kWh
5928 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
34 dB(A)
34 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
11.52 kW
10.57 kW
SCOP
5.67
4.25
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.19 kW
9.35 kW
COP Tj = -7°C
4.66
3.23
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
6.20 kW
5.69 kW
COP Tj = +2°C
5.81
4.27
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.99 kW
3.66 kW
COP Tj = +7°C
6.39
5.06
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.77 kW
2.73 kW
COP Tj = 12°C
5.67
4.67
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4195 kWh
5134 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.24 kW
14.24 kW
El input
2.01 kW
3.84 kW
COP
6.08
3.71
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
295 %
214 %
Prated
12.24 kW
14.24 kW
SCOP
7.57
5.56
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.24 kW
14.24 kW
COP Tj = +2°C
6.08
3.71
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.87 kW
9.16 kW
COP Tj = +7°C
7.15
4.96
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
3.50 kW
4.07 kW
COP Tj = 12°C
8.40
6.62
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2161 kWh
3425 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
300 %
223 %
Prated
12.24 kW
14.24 kW
SCOP
7.70
5.77
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.41 kW
8.62 kW
COP Tj = -7°C
7.43
5.28
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
4.51 kW
5.25 kW
COP Tj = +2°C
8.14
6.31
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.71 kW
3.37 kW
COP Tj = +7°C
8.35
7.00
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
3.68 kW
3.66 kW
COP Tj = 12°C
7.96
6.72
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3917 kWh
6086 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
292 %
213 %
Prated
12.24 kW
14.24 kW
SCOP
7.51
5.52
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.83 kW
12.60 kW
COP Tj = -7°C
6.35
4.09
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
6.59 kW
7.67 kW
COP Tj = +2°C
7.52
5.56
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.24 kW
4.93 kW
COP Tj = +7°C
8.40
6.49
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
3.70 kW
3.65 kW
COP Tj = 12°C
8.22
6.57
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3369 kWh
5331 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
8.42 kW
El input
1.09 kW
2.84 kW
COP
4.78
2.96
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
222 %
164 %
Prated
11.52 kW
10.57 kW
SCOP
5.76
4.29
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.52 kW
10.57 kW
COP Tj = +2°C
4.39
2.96
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.41 kW
6.79 kW
COP Tj = +7°C
5.38
3.81
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
3.29 kW
3.02 kW
COP Tj = 12°C
6.47
5.12
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2674 kWh
3290 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
226 %
168 %
Prated
11.52 kW
10.57 kW
SCOP
5.85
4.39
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.97 kW
6.40 kW
COP Tj = -7°C
5.69
4.02
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.24 kW
3.89 kW
COP Tj = +2°C
6.38
4.92
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.73 kW
2.50 kW
COP Tj = +7°C
5.79
4.88
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
2.78 kW
2.74 kW
COP Tj = 12°C
5.51
4.74
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4856 kWh
5928 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
162 %
Prated
11.52 kW
10.57 kW
SCOP
5.67
4.25
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.19 kW
9.35 kW
COP Tj = -7°C
4.66
3.23
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
6.20 kW
5.69 kW
COP Tj = +2°C
5.81
4.27
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.99 kW
3.66 kW
COP Tj = +7°C
6.39
5.06
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
2.77 kW
2.73 kW
COP Tj = 12°C
5.67
4.67
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
11.52 kW
10.57 kW
COP Tj = Tbiv
4.39
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.52 kW
10.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.96
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4195 kWh
5134 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.24 kW
14.24 kW
El input
2.01 kW
3.84 kW
COP
6.08
3.71
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
295 %
214 %
Prated
12.24 kW
14.24 kW
SCOP
7.57
5.56
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.24 kW
14.24 kW
COP Tj = +2°C
6.08
3.71
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
7.87 kW
9.16 kW
COP Tj = +7°C
7.15
4.96
Cdh Tj = +7 °C
0.99
1.00
Pdh Tj = 12°C
3.50 kW
4.07 kW
COP Tj = 12°C
8.40
6.62
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2161 kWh
3425 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
300 %
223 %
Prated
12.24 kW
14.24 kW
SCOP
7.70
5.77
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.41 kW
8.62 kW
COP Tj = -7°C
7.43
5.28
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
4.51 kW
5.25 kW
COP Tj = +2°C
8.14
6.31
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.71 kW
3.37 kW
COP Tj = +7°C
8.35
7.00
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
3.68 kW
3.66 kW
COP Tj = 12°C
7.96
6.72
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3917 kWh
6086 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
292 %
213 %
Prated
12.24 kW
14.24 kW
SCOP
7.51
5.52
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.83 kW
12.60 kW
COP Tj = -7°C
6.35
4.09
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
6.59 kW
7.67 kW
COP Tj = +2°C
7.52
5.56
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.24 kW
4.93 kW
COP Tj = +7°C
8.40
6.49
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
3.70 kW
3.65 kW
COP Tj = 12°C
8.22
6.57
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
12.24 kW
14.24 kW
COP Tj = Tbiv
6.08
3.71
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.24 kW
14.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.08
3.71
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3369 kWh
5331 kWh