Certificate holders

Subtype

Thermia Calibra Eco 8

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-C700110 / Issue 1
Certification Body
RISE CERT
Subtype title
Thermia Calibra Eco 8
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R452B
Mass of Refrigerant

0,900 kg

Certification Date
25.08.2021
Testing basis
EN 14511:2018, EN 14825:2018, EN 12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Thermia Calibra Eco 8 400V
Configure model
Model name
Thermia Calibra Eco 8 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.90 kW

6.21 kW

El input

1.06 kW

2.20 kW

COP

4.60

2.83

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

153 %

Prated

6.70 kW

6.24 kW

SCOP

5.65

4.01

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.70 kW

6.24 kW

COP Tj = +2°C

4.44

2.82

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

4.30 kW

4.01 kW

COP Tj = +7°C

5.47

3.61

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.54 kW

2.40 kW

COP Tj = 12°C

6.24

4.77

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1583 kWh

2076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.87

4.10

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.05 kW

3.77 kW

COP Tj = -7°C

5.68

3.81

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.47 kW

2.30 kW

COP Tj = +2°C

6.28

4.38

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.54 kW

2.41 kW

COP Tj = +7°C

6.30

4.93

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.53 kW

2.44 kW

COP Tj = 12°C

6.17

5.17

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2810 kWh

3748 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.57

4.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

5.52 kW

COP Tj = -7°C

4.73

3.12

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.36 kW

COP Tj = +2°C

5.70

4.10

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.32 kW

2.16 kW

COP Tj = +7°C

5.96

4.80

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.54 kW

2.16 kW

COP Tj = 12°C

6.28

5.05

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2485 kWh

3139 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.88 kW

8.39 kW

El input

1.53 kW

2.36 kW

COP

5.82

3.56

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

291 %

193 %

Prated

8.88 kW

8.39 kW

SCOP

7.49

5.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.88 kW

8.39 kW

COP Tj = +2°C

5.82

3.56

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.71 kW

5.39 kW

COP Tj = +7°C

7.44

4.59

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.28 kW

3.20 kW

COP Tj = 12°C

8.08

5.84

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1585 kWh

2235 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

306 %

205 %

Prated

8.88 kW

8.39 kW

SCOP

7.86

5.32

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.38 kW

5.08 kW

COP Tj = -7°C

7.81

4.79

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.27 kW

3.09 kW

COP Tj = +2°C

8.34

5.96

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

3.28 kW

3.21 kW

COP Tj = +7°C

8.17

6.09

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.28 kW

3.22 kW

COP Tj = 12°C

7.98

6.45

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3888 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

294 %

201 %

Prated

8.88 kW

8.39 kW

SCOP

7.56

5.23

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.86 kW

7.42 kW

COP Tj = -7°C

6.27

3.92

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.78 kW

4.52 kW

COP Tj = +2°C

7.94

5.34

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.07 kW

3.20 kW

COP Tj = +7°C

8.00

5.84

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.28 kW

2.16 kW

COP Tj = 12°C

8.14

6.63

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2428 kWh

3316 kWh

Thermia Calibra Eco 8 Duo 400V
Configure model
Model name
Thermia Calibra Eco 8 Duo 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.90 kW

6.21 kW

El input

1.06 kW

2.20 kW

COP

4.60

2.83

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

153 %

Prated

6.70 kW

6.24 kW

SCOP

5.65

4.01

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.70 kW

6.24 kW

COP Tj = +2°C

4.44

2.82

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

4.30 kW

4.01 kW

COP Tj = +7°C

5.47

3.61

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.54 kW

2.40 kW

COP Tj = 12°C

6.24

4.77

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1583 kWh

2076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.87

4.10

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.05 kW

3.77 kW

COP Tj = -7°C

5.68

3.81

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.47 kW

2.30 kW

COP Tj = +2°C

6.28

4.38

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.54 kW

2.41 kW

COP Tj = +7°C

6.30

4.93

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.53 kW

2.44 kW

COP Tj = 12°C

6.17

5.17

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2810 kWh

3748 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.57

4.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

5.52 kW

COP Tj = -7°C

4.73

3.12

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.36 kW

COP Tj = +2°C

5.70

4.10

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.32 kW

2.16 kW

COP Tj = +7°C

5.96

4.80

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.54 kW

2.16 kW

COP Tj = 12°C

6.28

5.05

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2485 kWh

3139 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.88 kW

8.39 kW

El input

1.53 kW

2.36 kW

COP

5.82

3.56

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

291 %

193 %

Prated

8.88 kW

8.39 kW

SCOP

7.49

5.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.88 kW

8.39 kW

COP Tj = +2°C

5.82

3.56

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.71 kW

5.39 kW

COP Tj = +7°C

7.44

4.59

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.28 kW

3.20 kW

COP Tj = 12°C

8.08

5.84

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1585 kWh

2235 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

306 %

205 %

Prated

8.88 kW

8.39 kW

SCOP

7.86

5.32

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.38 kW

5.08 kW

COP Tj = -7°C

7.81

4.79

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.27 kW

3.09 kW

COP Tj = +2°C

8.34

5.96

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

3.28 kW

3.21 kW

COP Tj = +7°C

8.17

6.09

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.28 kW

3.22 kW

COP Tj = 12°C

7.98

6.45

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3888 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

294 %

201 %

Prated

8.88 kW

8.39 kW

SCOP

7.56

5.23

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.86 kW

7.42 kW

COP Tj = -7°C

6.27

3.92

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.78 kW

4.52 kW

COP Tj = +2°C

7.94

5.34

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.07 kW

3.20 kW

COP Tj = +7°C

8.00

5.84

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.28 kW

2.16 kW

COP Tj = 12°C

8.14

6.63

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2428 kWh

3316 kWh

Thermia Calibra Eco 8 230V
Configure model
Model name
Thermia Calibra Eco 8 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.90 kW

6.21 kW

El input

1.06 kW

2.20 kW

COP

4.60

2.83

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

153 %

Prated

6.70 kW

6.24 kW

SCOP

5.65

4.01

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.70 kW

6.24 kW

COP Tj = +2°C

4.44

2.82

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

4.30 kW

4.01 kW

COP Tj = +7°C

5.47

3.61

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.54 kW

2.40 kW

COP Tj = 12°C

6.24

4.77

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1583 kWh

2076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.87

4.10

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.05 kW

3.77 kW

COP Tj = -7°C

5.68

3.81

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.47 kW

2.30 kW

COP Tj = +2°C

6.28

4.38

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.54 kW

2.41 kW

COP Tj = +7°C

6.30

4.93

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.53 kW

2.44 kW

COP Tj = 12°C

6.17

5.17

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2810 kWh

3748 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.57

4.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

5.52 kW

COP Tj = -7°C

4.73

3.12

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.36 kW

COP Tj = +2°C

5.70

4.10

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.32 kW

2.16 kW

COP Tj = +7°C

5.96

4.80

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.54 kW

2.16 kW

COP Tj = 12°C

6.28

5.05

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2485 kWh

3139 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.88 kW

8.39 kW

El input

1.53 kW

2.36 kW

COP

5.82

3.56

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

291 %

193 %

Prated

8.88 kW

8.39 kW

SCOP

7.49

5.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.88 kW

8.39 kW

COP Tj = +2°C

5.82

3.56

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.71 kW

5.39 kW

COP Tj = +7°C

7.44

4.59

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.28 kW

3.20 kW

COP Tj = 12°C

8.08

5.84

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1585 kWh

2235 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

306 %

205 %

Prated

8.88 kW

8.39 kW

SCOP

7.86

5.32

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.38 kW

5.08 kW

COP Tj = -7°C

7.81

4.79

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.27 kW

3.09 kW

COP Tj = +2°C

8.34

5.96

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

3.28 kW

3.21 kW

COP Tj = +7°C

8.17

6.09

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.28 kW

3.22 kW

COP Tj = 12°C

7.98

6.45

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3888 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

294 %

201 %

Prated

8.88 kW

8.39 kW

SCOP

7.56

5.23

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.86 kW

7.42 kW

COP Tj = -7°C

6.27

3.92

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.78 kW

4.52 kW

COP Tj = +2°C

7.94

5.34

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.07 kW

3.20 kW

COP Tj = +7°C

8.00

5.84

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.28 kW

2.16 kW

COP Tj = 12°C

8.14

6.63

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2428 kWh

3316 kWh

Thermia Calibra Eco 8 Duo 230V
Configure model
Model name
Thermia Calibra Eco 8 Duo 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.90 kW

6.21 kW

El input

1.06 kW

2.20 kW

COP

4.60

2.83

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

153 %

Prated

6.70 kW

6.24 kW

SCOP

5.65

4.01

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.70 kW

6.24 kW

COP Tj = +2°C

4.44

2.82

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

4.30 kW

4.01 kW

COP Tj = +7°C

5.47

3.61

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.54 kW

2.40 kW

COP Tj = 12°C

6.24

4.77

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1583 kWh

2076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.87

4.10

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.05 kW

3.77 kW

COP Tj = -7°C

5.68

3.81

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.47 kW

2.30 kW

COP Tj = +2°C

6.28

4.38

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.54 kW

2.41 kW

COP Tj = +7°C

6.30

4.93

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.53 kW

2.44 kW

COP Tj = 12°C

6.17

5.17

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2810 kWh

3748 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.57

4.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

5.52 kW

COP Tj = -7°C

4.73

3.12

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.36 kW

COP Tj = +2°C

5.70

4.10

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.32 kW

2.16 kW

COP Tj = +7°C

5.96

4.80

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.54 kW

2.16 kW

COP Tj = 12°C

6.28

5.05

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2485 kWh

3139 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.88 kW

8.39 kW

El input

1.53 kW

2.36 kW

COP

5.82

3.56

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

291 %

193 %

Prated

8.88 kW

8.39 kW

SCOP

7.49

5.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.88 kW

8.39 kW

COP Tj = +2°C

5.82

3.56

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.71 kW

5.39 kW

COP Tj = +7°C

7.44

4.59

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.28 kW

3.20 kW

COP Tj = 12°C

8.08

5.84

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1585 kWh

2235 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

306 %

205 %

Prated

8.88 kW

8.39 kW

SCOP

7.86

5.32

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.38 kW

5.08 kW

COP Tj = -7°C

7.81

4.79

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.27 kW

3.09 kW

COP Tj = +2°C

8.34

5.96

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

3.28 kW

3.21 kW

COP Tj = +7°C

8.17

6.09

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.28 kW

3.22 kW

COP Tj = 12°C

7.98

6.45

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3888 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

294 %

201 %

Prated

8.88 kW

8.39 kW

SCOP

7.56

5.23

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.86 kW

7.42 kW

COP Tj = -7°C

6.27

3.92

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.78 kW

4.52 kW

COP Tj = +2°C

7.94

5.34

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.07 kW

3.20 kW

COP Tj = +7°C

8.00

5.84

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.28 kW

2.16 kW

COP Tj = 12°C

8.14

6.63

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

8.88 kW

8.39 kW

COP Tj = Tbiv

5.82

3.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.88 kW

8.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.82

3.56

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2428 kWh

3316 kWh